Geri Dön

Meniere hastalığında servikal ve masseter vestibüler uyarılmış miyojenik potansiyeller arasındaki ilişkinin araştırılması

Investigation of the relationship between cervical and masseter vestibular evoked myogenic potentials in Meniere's disease

  1. Tez No: 1027044
  2. Yazar: BETÜL TEMİR
  3. Danışmanlar: DOÇ. DR. ZEHRA AYDOĞAN
  4. Tez Türü: Yüksek Lisans
  5. Konular: Kulak Burun ve Boğaz, Otorhinolaryngology (Ear-Nose-Throat)
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2026
  8. Dil: Türkçe
  9. Üniversite: Ankara Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Kulak Burun Boğaz Hastalıkları Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Meniere hastalığı tekrarlayan vertigo atakları, dalgalanan ve progresyon gösteren sensörinöral işitme kaybı, tinnitus ve kulakta dolgunluk hissi ile seyreden bir iç kulak hastalığıdır. Meniere hastalığında sakküler fonksiyon bozukluğunu tespit edebilen servikal vestibüler uyarılmış miyojenik potansiyeller (cVEMP) çoğunlukla tanılama, evreleme ve takip süreçlerinde kullanılmaktadır. cVEMP testi sakkülden başlayarak vestibülokolik refleks yolunun fonksiyonunu değerlendirir. cVEMP ile aynı periferik jeneratörden (sakkül) kaynaklanan masseterik vestibüler uyarılmış miyojenik potansiyeller (mVEMP) ise vestibülomasseterik refleks yolağını değerlendirir. Boyunda hareket sınırlılığı, nodül, kireçlenme, ağrı, servikal disk herni, geçirilmiş cerrahi gibi durumlar cVEMP testini uygulamada zorluklara, sonuçlarda anormalliğe veya yanıt yokluğuna sebep olabilmektedir. Bu bağlamda çalışmamızda Meniere hastalığında cVEMP ve mVEMP yanıtları arasındaki ilişkiyi incelemek ve mVEMP'in cVEMP testine alternatif olarak kullanılabilirliğini değerlendirmek amaçlanmıştır. Çalışmamıza 18-55 yaş arası, Barany Kriterlerine göre kesin Meniere tanısı almış 22 hasta ve 22 sağlıklı yetişkin dahil edilmiştir. Katılımcılar immitansmetrik değerlendirme ile saf ses odyometri testlerinden sonra cVEMP ve mVEMP testlerine alınmıştır. Her iki VEMP testi de 500 Hz tone burst uyaranla 100 dB nHL şiddet seviyesinde uygulanmıştır. P1 ve N1 latans süreleri, P1-N1 interval latans, P1-N1 dalga amplitüdü ve amplitüd asimetri oranları kaydedilmiştir. Hasta ve kontrol grubu arasında her iki VEMP testi için dalga var/yok oranları, hasta ve kontrol grubunun cVEMP ve mVEMP arasındaki dalga var/yok oranları kendi içerisinde, hasta grubu ve kontrol grubu arasında cVEMP ve mVEMP parametreleri, hasta grubu ve kontrol grubunun cVEMP ve mVEMP test parametreleri kendi içerisinde karşılaştırılmış, ek olarak hasta grubunun işitme kaybı, hastalığın durasyonu, hastalık şiddeti ve atak sıklığı değişkenlerinin hem cVEMP hem mVEMP test parametreleriyle korelasyonu değerlendirilmiştir. Analiz sonuçlarına göre hem cVEMP hem mVEMP yanıtları 17 (%77,3) hastada mevcuttur, kontrol grubunda ise katılımcıların hepsinde tüm yanıtlar mevcuttur ve kontrol grubunda anlamlı derecede daha fazla yanıt varlığı gözlenmiştir (p<0,05). Hasta grubunda her iki testte de yanıt var/yok oranları açısından var oranları anlamlı ölçüde daha fazladır (p<0,05). cVEMP parametreleri hasta ve kontrol grubu arasında karşılaştırılmış; hastalarda P1 ve N1 latasları daha uzun (p>0,05), amplitüd asimetri oranları daha fazladır (p>0,05), P1-N1 amplitüdü ise kontrol grubunda daha yüksektir (p<0,05). mVEMP parametreleri hasta ve kontrol grubunda karşılaştırılmış; P1 ve N1 latansları hasta grupta daha uzun, P1-N1 amplitüdü kontrol grubunda daha büyük, amplitüd asimetri oranı hasta grubunda daha yüksektir ancak bu karşılaştırmalar istatistiksel açıdan anlamsızdır (p>0,05). Hasta grubunda cVEMP ve mVEMP parametreleri karşılaştırılmış; latanslar cVEMP testinde daha uzun (p<0,05), P1-N1 amplitüdü mVEMP testinde daha büyük (p<0,05), amplitüd asimetri oranı cVEMP testinde daha fazladır (p>0,05). Kontrol grubunda cVEMP ve mVEMP parametreleri karşılaştırılmış; P1 (p>0,05) ve N1 (p<0,05) latansları cVEMP testinde daha uzun, P1-N1 amplitüd değeri mVEMP testinde daha büyük (p>0,05), amplitüd asimetri oranı cVEMP testinde daha fazla elde edilmiştir (p>0,05). Korelasyon bulguları incelendiğinde işitme kaybı, durasyon, hastalık şiddeti ve atak sıklığı ile cVEMP parametreleri arasında anlamlı korelasyon elde edilememiştir (p>0,05). mVEMP testi ile hastalık özellikleri arasındaki korelasyonda ise işitme kaybı ile N1 latans süresi arasında negatif yönlü, asimetri oranı arasında pozitif yönlü anlamlı korelasyonlar elde edilmiştir (p<0,05). Sonuç olarak Meniere hastalarında mVEMP testinde cVEMP testine göre daha kısa latanslar, daha büyük amplitüd ve benzer asimetri oranları elde edilmiştir, bu durum süre açısından uygulamada kolaylık sağlayabilir. mVEMP'in Meniere hastalarında alternatif bir test yöntemi olarak diğer testlerle birlikte kullanımının faydalı olabileceğini düşünmekteyiz.

Özet (Çeviri)

Meniere's disease is an inner ear disorder characterized by recurrent vertigo attacks, fluctuating and progressive sensorineural hearing loss, tinnitus, and a feeling of fullness in the ear. Cervical vestibular evoked myogenic potentials (cVEMP), which can detect saccular dysfunction in Meniere's disease, are frequently used in diagnosis, staging, and follow-up. The cVEMP test evaluates the function of the vestibulocolic reflex pathway, starting from the saccule. Masseteric vestibular evoked myogenic potentials (mVEMP), originating from the same peripheral generator (saccule) as cVEMP, evaluate the vestibulomassesteric reflex pathway. Conditions such as limited neck movement, nodules, calcification, pain, cervical disc herniation, and previous surgery can cause difficulties in performing the cVEMP test, leading to abnormal results or no response. In this context, our study aimed to examine the relationship between cVEMP and mVEMP responses in Meniere's disease and to evaluate the usability of mVEMP as an alternative to the cVEMP test. Our study included 22 patients aged 18-55 years with a definitive diagnosis of Meniere's disease according to the Barany Criteria and 22 healthy adults. Participants underwent cVEMP and mVEMP tests after immitansmetric evaluation and pure tone audiometry. Both VEMP tests were performed with a 500 Hz tone burst stimulus at a 100 dB nHL intensity level. P1 and N1 latency durations, P1-N1 interval latency, P1-N1 wave amplitude, and amplitude asymmetry ratios were recorded. The wave presence/absence ratios for both VEMP tests were compared between the patient and control groups, the wave presence/absence ratios between cVEMP and mVEMP were compared within the patient and control groups, cVEMP and mVEMP parameters were compared between the patient and control groups, and cVEMP and mVEMP test parameters were compared within the patient and control groups. Additionally, the correlation of hearing loss, disease duration, disease severity, and attack frequency variables with both cVEMP and mVEMP test parameters was evaluated in the patient group. According to the analysis results, both cVEMP and mVEMP responses were present in 17 (77.3%) patients, while in the control group, all participants had all responses, and a significantly higher number of responses were observed in the control group (p<0.05). In the patient group, the presence/absence ratios for both tests were significantly higher (p<0.05). cVEMP parameters were compared between the patient and control groups; In patients, P1 and N1 latencies were longer (p>0.05), amplitude asymmetry rates were higher (p>0.05), while P1-N1 amplitude was higher in the control group (p<0.05). mVEMP parameters were compared in the patient and control groups; P1 and N1 latencies were longer in the patient group, P1-N1 amplitude was larger in the control group, and amplitude asymmetry rate was higher in the patient group, but these comparisons were not statistically significant (p>0.05). cVEMP and mVEMP parameters were compared in the patient group; latencies were longer in the cVEMP test (p<0.05), P1-N1 amplitude was larger in the mVEMP test (p<0.05), and amplitude asymmetry rate was higher in the cVEMP test (p>0.05). cVEMP and mVEMP parameters were compared in the control group; P1 (p>0.05) and N1 (p<0.05) latencies were longer in the cVEMP test, the P1-N1 amplitude value was larger in the mVEMP test (p>0.05), and the amplitude asymmetry ratio was higher in the cVEMP test (p>0.05). When the correlation findings were examined, no significant correlation was obtained between hearing loss, duration, disease severity, and attack frequency and the cVEMP parameters (p>0.05). In the correlation between the mVEMP test and disease characteristics, a significant negative correlation was obtained between hearing loss and N1 latency duration, and a significant positive correlation was obtained between hearing loss and the asymmetry ratio (p<0.05). In conclusion, in Meniere's disease patients, shorter latencies, larger amplitudes, and similar asymmetry ratios were obtained in the mVEMP test compared to the cVEMP test, which may provide ease of application in terms of time. We believe that the use of mVEMP as an alternative test method in Meniere's disease patients in combination with other tests may be beneficial.

Benzer Tezler

  1. Meniere hastalığında endolenfatik kese cerrahisi

    Endolymphatic sac surgery in meniere's disease

    NEBİL GÖKSU

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1987

    Gazi Üniversitesi

    Kulak Burun Boğaz Ana Bilim Dalı

    Yükleniyor...

  2. Türk sermaye piyasasının ekonomik analizi ve Türkiyede hisse senedi fiyatlarını belirleyen etkenler

    L Analyse econoique du marche du capital turc et les facteurs qui determinent les prix des actions en turquie

    SADUN ABAÇ

    Doktora

    Türkçe

    Türkçe

    1986

    İstanbul Teknik Üniversitesi

    İşletme Ana Bilim Dalı

    Yükleniyor...

  3. Augustinus estetik'ine genel bir bakış

    Başlık çevirisi yok

    AYŞE SERPİL BAHADIRLI

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    İstanbul Üniversitesi

    Yükleniyor...

  4. Menstrüasyon siklusunun meniere atakları üzerine etkisinin incelenmesi

    Başlık çevirisi yok

    SELDA KESMEZ

    Yüksek Lisans

    Türkçe

    Türkçe

    1988

    Hacettepe Üniversitesi

    Odyoloji Ana Bilim Dalı

    Yükleniyor...

  5. L' Approche communicative et les documents authentiques dans l'enseignement de la langue et de la litterature Françaises aux universites

    Başlık çevirisi yok

    N.YASEMİN İNAN

    Doktora

    Fransızca

    Fransızca

    1988

    Hacettepe Üniversitesi

    Fransız Dili ve Edebiyatı Ana Bilim Dalı

    Yükleniyor...