Geri Dön

Sürekli çalışan yanma odası destekli güneş enerjili sCO2 Rankine çevriminin enerji ve ekserji analizi

Energy and exergy analysis of a continuously operating combustion chamber assisted solar powered sCO2 Rankine cycle

  1. Tez No: 1027761
  2. Yazar: GÖRKEM ŞAHİN
  3. Danışmanlar: PROF. DR. ALİ KOÇ, DOÇ. DR. ÖZKAN KÖSE
  4. Tez Türü: Yüksek Lisans
  5. Konular: Makine Mühendisliği, Mechanical Engineering
  6. Anahtar Kelimeler: Güneş enerjisi, Rankine çevrimi, Yanma odası, Solar energy, Rankine cycle, Combustion chamber
  7. Yıl: 2026
  8. Dil: Türkçe
  9. Üniversite: İskenderun Teknik Üniversitesi
  10. Enstitü: Lisansüstü Eğitim Enstitüsü
  11. Ana Bilim Dalı: Makine Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Makine Mühendisliği Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmada, parabolik oluklu kolektör ile entegre güneş enerjili süperkritik karbondioksit Rankine çevrim sisteminin, güneş enerjisi (radyasyon) desteği almadığı süreler boyunca, sistemin sürekli çalışması için bu sisteme yanma odası destekli bir tasarım eklenmiştir. Öncelikle yanma odası desteği olmadan ve daha sonra yanma odalı destekli sistem göz önünde bulundurulup değerlendirilmiştir. Belirli bir bölgenin, güneş enerjisi radyasyon verileri alınıp, bu radyasyon verileri bir yıl boyunca değerlendirilmiş ve termodinamik performansı gözlemlenmiştir. Daha sonra bu veriler Ebsilon Professional programına kaydedilip işlenmiştir. Akabinde, sisteme ait parametrelerin analizi, program ile tasarımı ve nümerik hesaplamaların veri analizi programlarıyla yapılmıştır. Bu sistemde kullanılan ısı kaynağının sCO2 Rankine çevriminde değerlendirilmesi ve yanma odasının çalıştırılması ile sürekli hale getirilmesi üzerine çalışma gerçekleştirilmiştir. Çalışma sonucunda, sCO2 çevrimindeki en yüksek enerji verimi 550 °C sıcaklık ve 600 bar basınçta %41,73 oranında bulunup akabinde en iyi enerji verim noktasındaki kütlesel debi değişiminin en yüksek değeri temmuz ayı içerisinde 408,75 kg/s olarak tespit edilmiştir. Bu çevrimin yılın her ayı içerisinde enerji veriminin %41,73 oranında istikrarını sürdürdüğü belirlenirken, ekserji veriminin en düşük ve en yüksek oranları sırası ile %72-%77 olarak bulunmuştur. Bununla birlikte pompa güç tüketiminin minimum değeri 29316,56 kW ve maksimum değeri 29699,40 kW olarak tespit edilip, net gücün değeri maksimum 74478,8 kW'tır. Son olarak, elde edilen en yüksek net termal verim 600 bar ve 550 °C değerlerinde %41,73 oranında bulunmuş ve en yüksek ekserji verim değeri temmuz ayında %71,2 olarak hesaplanmıştır.

Özet (Çeviri)

In this study, a combustion chamber-supported design was incorporated into a solar-powered sCO2 (supercritical carbon dioxide) Rankine cycle system integrated with a PTC (parabolic trough collector) to ensure continuous system operation during periods when solar energy (radiation) is unavailable. First, the system was evaluated without combustion chamber support, and subsequently, the combustion chamber-supported system was considered and evaluated. Solar radiation data for a specific region were collected, evaluated over a one-year period, and the thermodynamic performance was observed. Subsequently, these data were recorded and processed using the Ebsilon Professional program. Following this, the analysis of the system's parameters, the design using the program, and the data analysis of numerical calculations were performed using data analysis software. A study was conducted on the evaluation of the heat source used in this system within the sCO2 Rankine cycle and on ensuring continuous operation through the operation of the combustion chamber. As a result of the study, the highest energy efficiency in the sCO2 cycle was found to be 41.73% at a temperature of 550 °C and a pressure of 600 bar; subsequently, the highest value of the mass flow rate variation at the point of maximum energy efficiency was determined to be 408.75 kg/s during the month of July. It was determined that the energy efficiency of this cycle remained stable at 41.73% throughout the year, while the exergy efficiency ranged from a minimum of 72% to a maximum of 77%. Furthermore, the minimum pump power consumption was determined to be 29316.56 kW and the maximum value 29699.40 kW, with the net power reaching a maximum of 74478.8 kW. Finally, the highest net thermal efficiency obtained was 41.73% at 600 bar and 550 °C, and the highest exergy efficiency value was calculated as 71.2% in July.

Benzer Tezler

  1. Yeni Cami'nin akustik açıdan performans değerlendirmesi

    Evaluation of the acoustical performance of the New Mosque

    EVREN YILDIRIM

    Yüksek Lisans

    Türkçe

    Türkçe

    2003

    İstanbul Teknik Üniversitesi

    Mimarlık Ana Bilim Dalı

    Yükleniyor...

  2. Prostat adenokarsinomlarında psa değerlerinin gleason skor ve klinik evre ile ilişkisi

    The relation between psa and gleason score and clinical phase in prostate adenocarsinoma

    HACI HASAN ESEN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2005

    Selçuk Üniversitesi

    Patoloji Ana Bilim Dalı

    Yükleniyor...

  3. Kuyruk modelleri ve analizi üzerine bir uygulama

    Başlık çevirisi yok

    DİDEM ÖZPULAT

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Bilgisayar Bilimleri ve Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  4. Adolesan intihar girişimlerinin psiko-sosyal nedenleriyle ilgili araştırma

    Başlık çevirisi yok

    NAZMİYE YÜKSEL

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    İstanbul Üniversitesi

    Aile Sağlığı Ana Bilim Dalı

    Yükleniyor...

  5. Çocuklarda akut stres hiperglisemisinde hormonal değişikliklerin ve kısa süreli prognozun incelenmesi

    Başlık çevirisi yok

    AYGÜN DİNDAR

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1987

    İstanbul Üniversitesi

    Çocuk Sağlığı ve Hastalıkları Hemşireliği Ana Bilim Dalı

    Yükleniyor...