Geri Dön

Nükleer tıpta tanısal tetkiklerden sonra hastalardan yayılan radyasyonun yakın mesafelerdeki doz hızlarının ölçülmesi ve doz maruziyetinin değerlendirilmesi

Close-distance dose of radiation emited from patients after diagnostic examinations in nucleer medicine measuring their speeds and evaluating dose exposure

  1. Tez No: 1029325
  2. Yazar: YILMAZ DEMİRCİ
  3. Danışmanlar: PROF. DR. MUSTAFA DEMİR
  4. Tez Türü: Yüksek Lisans
  5. Konular: Fiziksel Tıp ve Rehabilitasyon, Radyoloji ve Nükleer Tıp, Physical Medicine and Rehabilitation, Radiology and Nuclear Medicine
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2026
  8. Dil: Türkçe
  9. Üniversite: İstanbul Aydın Üniversitesi
  10. Enstitü: Lisansüstü Eğitim Enstitüsü
  11. Ana Bilim Dalı: Sağlık Yönetimi Ana Bilim Dalı
  12. Bilim Dalı: Sağlık Fiziği Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Tanısal nükleer tıp uygulamalarında radyofarmasötik uygulanan hastalar tetkik sonrasında çevrelerinde dış radyasyon tehlikesi yaratıp, özellikle yakın mesafede bulunan sağlık personeli ve hasta yakınları için potansiyel maruziyet kaynağı oluşturur. Bu çalışmada, nükleer tıpta en yüksek aktivite miktarının kullanıldığı üç tanısal tetkik sonrası hastalardan yayılan radyasyonun yakın mesafelerdeki doz hızı düzeyleri ölçülmüş olup mesafeye bağlı doz hızı değişimleri değerlendirilmiştir. Tc-99m MDP tüm vücut kemik sintigrafisi (n=23), Tc-99m MIBI miyokard perfüzyon sintigrafisi (n=22) ve F-18 FDG PET/BT (n=22) yapılan toplam 67 hastada çekim bitiminde hasta masadan kalktığı anda batın bölgesinden anterior yönde ölçümler alınmıştır. Ölçümler Ludlum Model 9DP-1 survey metre (Ürün No.: 343-352, kalibrasyon Mayıs 2025) ile her mesafede okumanın kararlı hale gelmesi beklenerek ortalama 2 sn.’lik ölçüm süresiyle gerçekleştirilmiş; 5, 15, 30, 60 ve 100 cm. mesafelerde doz hızı değerleri kaydedilmiştir. 5 cm mesafede ortalama doz hızı MDP’de 134,0 ± 37,0 μSv/h, MIBI’de 57,9 ± 18,9 μSv/h ve FDG PET/BT’de 205,3 ± 20,9 μSv/h bulunmuştur. Mesafe arttıkça tüm gruplarda doz hızı belirgin şekilde azalmış, 100 cm mesafede ortalamalar sırasıyla 13,9 ± 6,6 μSv/h, 6,9 ± 4,8 μSv/h ve 17,2 ± 3,5 μSv/h bulunmuştur. 5 cm’den 100 cm’ye geçişte ortalama doz hızı azalımı MDP’de %89,6; MIBI’de %88,1; FDG’de %91,6 ölçülmüştür. Bulgularımız özellikle batın bölgesindeki (böbrek-mesane) aktivite birikimi nedeniyle yakın temas koşullarında maruziyetin anlamlı olabileceğini, buna karşın mesafe arttığında maruziyetin anlamlı şekilde düşdüğünü göstermektedir. Sonuç olarak hastaların diğer insanlar ile 100 cm ve daha fazla sosyal mesafelerde bulundukları durumda radyasyon maruziyetinin güvenli düzeyde tutulabileceğini ortaya koymaktadır.

Özet (Çeviri)

In diagnostic nuclear medicine procedures, patients who receive radiopharmaceuticals pose an external radiation hazard to their surroundings following the examination, creating a potential source of exposure, particularly for healthcare personnel and patient’s relatives in close proximity. In this study, radiation dose rates emitted by patients at close range were measured following three diagnostic procedures involving the highest activity levels in nuclear medicine and dose rate variations with distance were evaluated: Tc-99m MDP whole-body bone scintigraphy (n=23), Tc-99m MIBI myocardial perfusion scintigraphy (n=22) and F-18 FDG PET/CT (n=22). Measurements were taken in the anterior direction from the abdominal region immediately after the patient rose from the table at the end of the scan, Measurements were performed using a Ludlum Model 9DP-1 survey meter (Product No.: 343-352; calibration May 2025); measurements were taken at distances of 5, 15, 30, 60 and 100 cm, with an average measurement duration of 2 seconds, waiting for the reading to stabilize at each distance; dose rate values were recorded at these distances. At a 5 cm distance, the average dose rate was 134.0 ± 37.0 μSv/h for MDP, 57.9 ± 18.9 μSv/h for MIBI and 205.3 ± 20.9 μSv/h for FDG PET/CT. As the distance increased, the dose rate decreased significantly in all groups; at a distance of 100 cm, the averages were 13.9 ± 6.6, 6.9 ± 4.8 and 17.2 ± 3.5 μSv/h respectively. The average dose rate reduction from 5 cm to 100 cm was measured as 89.6% for MDP, 88.1% for MIBI and 91.6% for FDG. Our findings indicate that exposure may be significant under close-contact conditions, particularly due to activity accumulation in the abdominal region (kidney-bladder); however, exposure decreases significantly as the distance increases. In conclusion, this demonstrates that radiation exposure can be maintained at safe levels when patients are at a social distance of 100 cm or more from other people.

Benzer Tezler

  1. Hepatik venöz A-R indekslerinin pulmoner arter çapı ile korelasyonunun araştırılması

    A study about whether there's A correlation between hepatic venous A-R indices and pulmonary artery diameter

    TAHA YASİN ARSLAN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2021

    Balıkesir Üniversitesi

    Radyoloji Ana Bilim Dalı

    Yükleniyor...

  2. Nükleer rezonasta moleküler yapıların incelenmesi (yapısal faz geçiş kuramları üzerine bir inceleme)

    Başlık çevirisi yok

    ABDURRAHMAN ANDİÇ

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Uludağ Üniversitesi

    Fizik Ana Bilim Dalı

    Yükleniyor...

  3. 5 Cl Pu-Be nötron kaynağı kullanarak aktivasyon analizi ile analizi mümkün olan elementlerin dedeksiyon limitlerinin tespiti

    Investigation of the possibility in analysis of elements by activation analysis and determination of detection limits of proposed elements using a 5 Cl Pu-Be neutron source

    İSMET ÇELENK

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Gazi Üniversitesi

    Yükleniyor...

  4. Sürekli rejim şartlarında nükleer yakıt çubuklarında tek ve iki boyutlu ısı iletiminin analizi

    In steady-state conditions analyses of one and two dimensional conduction in nuclear fuel rods

    İBRAHİM ATILGAN

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    Gazi Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  5. Sivas yöresinde os trigonum oranının radyolojik olarak araştırılması

    An Investigation about the incidence of os trigonumin Sivas

    MEHMET ÇİMEN

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    Cumhuriyet Üniversitesi

    Morfoloji Ana Bilim Dalı

    Yükleniyor...