Geri Dön

Hibrit batarya termal yönetim sisteminde tasarım ve işletme faktörlerinin yanıt yüzey yöntemiyle incelenmesi ve optimizasyonu

Investigation and optimization of design and operating factors in a hybrid battery thermal management system using the response surface methodology

  1. Tez No: 1030004
  2. Yazar: ECE NUR BULUT
  3. Danışmanlar: DOÇ. DR. MUSTAFA YUSUF YAZICI, DR. ÖĞR. ÜYESİ MELİH YILDIZ
  4. Tez Türü: Yüksek Lisans
  5. Konular: Enerji, Makine Mühendisliği, Energy, Mechanical Engineering
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2026
  8. Dil: Türkçe
  9. Üniversite: Samsun Üniversitesi
  10. Enstitü: Lisansüstü Eğitim Enstitüsü
  11. Ana Bilim Dalı: Makine Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Enerji Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Lityum-iyon bataryaların güvenli, verimli ve uzun ömürlü çalışabilmesi için hücre sıcaklıklarının uygun çalışma aralığında tutulması ve batarya paketi içerisindeki sıcaklık dağılımının mümkün olduğunca dengeli olması gerekmektedir. Yüksek deşarj oranları ve yüksek ortam sıcaklıkları; batarya hücrelerinde aşırı sıcaklık artışına, sıcaklık tekdüzeliğinin bozulmasına ve termal güvenlik risklerinin artmasına neden olabilmektedir. Bu tez çalışmasında, 18650 tipi 16 adet silindirik lityum-iyon hücreden oluşan bir batarya paketi için faz değiştiren madde/genişletilmiş grafit (FDM/GG) kompoziti ile sıvı soğutmanın birlikte kullanıldığı hibrit bir batarya termal yönetim sistemi sayısal olarak incelenmiştir. Çalışmada soğutucu akışkan debisi, dış ortamla olan ısı taşınım katsayısı, ortam sıcaklığı, serpantin boruların düşey konumu ve boru konfigürasyonu temel tasarım ve çalışma parametreleri olarak ele alınmıştır. Batarya konfigürasyonu tek giriş-tek çıkış, iki giriş-iki çıkış, üç giriş-üç çıkış olmak üzere üç farklı tasarım üzerinden değerlendirilmiştir. Bu faktörlerin maksimum hücre sıcaklığı, sıcaklık tekdüzeliği, FDM/GG kompozitinin sıvı fraksiyonu ve soğutma hattındaki basınç düşümü üzerindeki etkileri 2C ve 3C deşarj oranları için hesaplamalı akışkanlar dinamiği yaklaşımıyla analiz edilmiştir. Elde edilen sayısal sonuçlar, Yanıt Yüzey Yöntemi kullanılarak değerlendirilmiş ve parametrelerin ana etkileri ile etkileşimleri belirlenmiştir. Elde edilen sonuçlar ile her iki deşarj oranında da termal tepkiler üzerinde en etkili değişkenlerin ortam sıcaklığı ve soğutucu akışkan debisi olduğu ortaya konulmuştur. Soğutucu akışkanın debisinin artırılması maksimum hücre sıcaklığını düşürürken basınç kaybını artırmış; ortam sıcaklığındaki artış ise hem maksimum sıcaklığı hem de FDM/GG kompozitinin sıvı fraksiyonunu yükseltmiştir. Pasif soğutma analizleri, FDM/GG kompozitinin tek başına, özellikle yüksek deşarj oranı ve yüksek ortam sıcaklığı koşullarında batarya paketini uygun çalışma sıcaklığı aralığında tutmakta yetersiz kaldığını göstermiştir.

Özet (Çeviri)

For lithium-ion batteries to operate safely, efficiently, and with a long lifespan, cell temperatures must be maintained within the appropriate operating range, and the temperature distribution within the battery pack must be as uniform as possible. High discharge rates and high ambient temperatures can lead to excessive temperature rise in battery cells, degradation of temperature uniformity, and increased thermal safety risks. In this thesis study, a hybrid battery thermal management system combining a phase change material/expanded graphite (PCM/EG) composite and liquid cooling was numerically investigated for a battery pack consisting of 16 cylindrical 18650-type lithium-ion cells. In the study, coolant flow rate, convective heat transfer coefficient with the external environment, ambient temperature, vertical position of the serpentine tubes, and tube configuration were considered as the primary design and operating parameters. The battery configuration was evaluated across three different designs: single inlet-single outlet, two inlets-two outlets, and three inlets-three outlets. The effects of these factors on the maximum cell temperature, temperature uniformity, liquid fraction of the PCM/EG composite, and pressure drop in the cooling line were analyzed using a computational fluid dynamics approach for 2C and 3C discharge rates. The obtained numerical results were evaluated using the Response Surface Methodology, and the main effects and interactions of the parameters were determined. The results revealed that ambient temperature and coolant flow rate were the most influential variables on thermal responses at both discharge rates. Increasing the coolant flow rate decreased the maximum cell temperature while increasing the pressure drop; conversely, an increase in ambient temperature elevated both the maximum temperature and the liquid fraction of the PCM/EG composite. Passive cooling analyses demonstrated that the PCM/EG composite alone was insufficient to maintain the battery pack within the appropriate operating temperature range, especially under conditions of high discharge rates and high ambient temperatures.

Benzer Tezler

  1. Kemalpaşa etlik piliç işletmelerinin teknik ve ekonomik yönden incelenmesi

    Başlık çevirisi yok

    HAYRİ TUNA YÜKSELEN

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    Ege Üniversitesi

    Zootekni Ana Bilim Dalı

    Yükleniyor...

  2. Rana ridibunda (anura-ranidae) kompleksi üzerinde morfolojik, serolojik ve ekolojik araştırmalar

    Başlık çevirisi yok

    HÜSEYİN ARIKAN

    Doktora

    Türkçe

    Türkçe

    1987

    Ege Üniversitesi

    Zooloji Ana Bilim Dalı

    Yükleniyor...

  3. Melez kayısı populasyonunda seleksiyon çalışması

    Başlık çevirisi yok

    H.ŞEBNEM KAHYA(ÖZCAN)

    Yüksek Lisans

    Türkçe

    Türkçe

    1988

    Ege Üniversitesi

    Bahçe Bitkileri Ana Bilim Dalı

    Yükleniyor...

  4. Konikal horn antenler

    Başlık çevirisi yok

    SALİH CÜCE

    Yüksek Lisans

    Türkçe

    Türkçe

    1989

    Uludağ Üniversitesi

    Elektronik Mühendisliği Ana Bilim Dalı

    Yükleniyor...