Yetişkin Tip1 DM hastalarında yeni diyabet teknolojilerinin kullanımının metabolik, laboratuvar parametreler ile yaşam kalitesi üzerine etkisi
The effect of new diabetes technologies on metabolic and laboratory parameters and quality of life in adult patients with Type 1 diabetes mellitus
- Tez No: 1031799
- Danışmanlar: DOÇ. DR. MAHMUT APAYDIN
- Tez Türü: Tıpta Uzmanlık
- Konular: İç Hastalıkları, Internal diseases
- Anahtar Kelimeler: Belirtilmemiş.
- Yıl: 2025
- Dil: Türkçe
- Üniversite: Afyonkarahisar Sağlık Bilimleri Üniversitesi
- Enstitü: Tıp Fakültesi
- Ana Bilim Dalı: İç Hastalıkları Ana Bilim Dalı
- Bilim Dalı: İç Hastalıkları Bilim Dalı
- Sayfa Sayısı: Belirtilmemiş.
Özet
Amaç: Bu çalışmanın amacı, Tip 1 diyabetes mellitus (T1DM) tanılı erişkin bireylerde yeni nesil diyabet teknolojilerinin özellikle insülin pompa sistemleri ve sürekli glukoz izleme (CGM) cihazlarının—metabolik kontrol, laboratuvar parametreleri ve yaşam kalitesi üzerine etkilerini değerlendirmektir. Gereç–Yöntem: Ocak 2020–Ekim 2025 tarihleri arasında Afyonkarahisar Sağlık Bilimleri Üniversitesi Tıp Fakültesi Endokrin ve Metabolizma Hastalıkları Polikliniği'nde insülin pompası kullanan 61 Tip 1 DM hastası retrospektif olarak incelendi. Katılımcıların 23'ü (%37,7) Medtronic 780G, 38'i (%62,3) MiniMed cihazı kullanmaktaydı. Hastaların demografik özellikleri, laboratuvar değerleri ve klinik bulguları hasta dosyalarından elde edildi. Yaşam kalitesi ve cihaz memnuniyeti düzeyleri, Insulin Device Satisfaction Survey (IDSS) ve Glucose Monitoring Satisfaction Survey (GMSS) ölçekleri kullanılarak değerlendirildi. Bulgular: Çalışma grubunun yaş ortalaması 32,6 ± 9,9 yıl olup, katılımcıların %57,4'ü kadındı. Pompa tedavisi sonrasında HbA1c ve açlık plazma glukoz düzeylerinde istatistiksel olarak anlamlı azalma saptandı (p<0,001). Üre, kreatinin, lipid profili ve karaciğer enzimlerinde anlamlı fark bulunmazken; spot idrar albümin (p<0,001) ve protein (p=0,027) düzeylerinde artış gözlendi. IDSS ölçeğine göre katılımcıların %67,2'si yüksek, %32,8'i orta düzeyde memnuniyet bildirdi. GMSS'ye göre ise %83'ü orta düzeyde memnuniyet gösterdi. Cihaz grupları arasında memnuniyet farkı anlamlı bulunmadı (p=0,558). 780G grubunda hipoglisemi oranı MiniMed grubuna göre daha düşük saptandı. En sık görülen komorbidite hipotiroidi (%30,7) idi. Sonuç: Yeni nesil diyabet teknolojilerinin, Tip 1 DM hastalarında glisemik kontrolü iyileştirdiği, hipoglisemi sıklığını azalttığı ve hasta memnuniyetini artırarak yaşam kalitesine olumlu katkı sağladığı sonucuna varılmıştır. Her iki cihaz tipi benzer klinik etkinlik göstermiş olup, 780G sisteminin hipoglisemi yönetiminde ek avantaj sunduğu düşünülmektedir.
Özet (Çeviri)
Objective: The aim of this study was to evaluate the effects of new-generation diabetes technologies—particularly insulin pump therapy and continuous glucose monitoring (CGM) systems—on metabolic control, laboratory parameters, and quality of life in adult patients with Type 1 diabetes mellitus (T1DM). Material–Methods: A total of 61 adult patients with T1DM who used insulin pump therapy and were followed up at Afyonkarahisar Health Sciences University, Faculty of Medicine, Department of Endocrinology and Metabolism between January 2020 and October 2025 were retrospectively analyzed. Of these, 23 patients (37.7%) used the Medtronic 780G system and 38 (62.3%) used MiniMed devices. Demographic, clinical, and laboratory data were obtained from patient records. Quality of life and device satisfaction levels were evaluated using the Insulin Device Satisfaction Survey (IDSS) and Glucose Monitoring Satisfaction Survey (GMSS) scales. Results: The mean age of the study population was 32.6 ± 9.9 years, and 57.4% were female. Following pump therapy, there was a statistically significant reduction in HbA1c and fasting plasma glucose levels (p<0.001). No significant differences were observed in urea, creatinine, lipid profile, or liver enzymes, whereas a significant increase was detected in spot urine albumin (p<0.001) and protein (p=0.027) levels. According to the IDSS, 67.2% of participants reported high and 32.8% moderate satisfaction levels. Based on the GMSS, 83% showed moderate satisfaction. No statistically significant difference in satisfaction levels was found between device types (p=0.558). Hypoglycemia frequency was lower in the 780G group compared to the MiniMed group. The most common comorbidity was hypothyroidism (30.7%). Conclusion: New-generation diabetes technologies improve glycemic control, reduce the frequency of hypoglycemia, and enhance patient satisfaction and quality of life in adults with Type 1 diabetes. Both device types demonstrated similar clinical effectiveness, while the 780G system provided an additional advantage in hypoglycemia management.
Benzer Tezler
- Diyabetik acil nedeniyle başvuran hastaların özellikleri
The features of patients hospitalized due to diabetic emergency
FEYZİ KARA
- Tip 1 diyabet patogenezinde işlenmiş ve ultra işlenmiş besin tüketiminin etkisi
Effect of processed and ultra-processed food consumption on type 1 diabetes pathogenesis
SÜMEYYE BETÜL TURGUT
Tıpta Uzmanlık
Türkçe
2023
Sağlık Bilimleri ÜniversitesiÇocuk Sağlığı ve Hastalıkları Ana Bilim Dalı
Yükleniyor...
- BCS Sınıf II bir antidiyabetik ve BCS Sınıf IV bir diüretik için nanokristal bazlı formülasyonların geliştirilmesi ve karakterizasyonu
Development and characterization of nanocrystal-based formulations for a BCS class II antidiabetic and a BCS class IV diuretic
FATIMA KHALIFA M. A. AL-SULAITI
- Morbid obez hastalarda laparoskopik roux Y gastrik bypass ile biliopankreatik diversiyon ameliyatının erken dönem klinik ve metabolik sonuçlarının karşılaştırılması
Morbidly obese patients laparoscopic roux - Y gastric bypass biliopancreatic diversion with your surgery comparison of early clinical and metabolic
MUSTAFA TÜRKAY BELEN
- Tip 2 diabetes mellituslu yetişkin hastaların glisemik kontrol durumu ve ilişkili faktörler
Adult Type 2 diabetes mellitus patients' glycemic control status and related factors
ELİF SAMİYE BAYAR