Geri Dön

Assessment of air pollution in Ankara with the use of microbiological methods

Başlık çevirisi mevcut değil.

  1. Tez No: 13174
  2. Yazar: CANAN AŞÇIOĞLU
  3. Danışmanlar: PROF.DR. HASAN BAĞCI
  4. Tez Türü: Yüksek Lisans
  5. Konular: Çevre Mühendisliği, Environmental Engineering
  6. Anahtar Kelimeler: Hava kirliliği Muta j enler, DNA onarım testi, Salmonella typhimurium, Bacillus thüringjensis, Escherichiae coli
  7. Yıl: 1991
  8. Dil: İngilizce
  9. Üniversite: Orta Doğu Teknik Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Belirtilmemiş.
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 54

Özet

ÖZET Ankaraıım Hava Kirliliğinin Mikrobiolo j ik Yöntemlerle Belirlenmesi AŞCIO?LU, Canan Yüksek Lisans Tezi, Biyoloji Bölümü Tez Yöneticisi: Prof. Dr. Hasan BA?CI Şubat 1991, 5ü sayfa. Birçok çalışma, içinde yaşadığımız havada bulunan gaz ve parçacıkların muta j enik özelliği olabileceğini gösteriyor. Yapılan incelemelerin çoğu endüstri yoğun, şehir yada şehir yakınlarında olan spesifik kirlilik kaynaklarında gösterilmiştir. Bu çalışmanın amacı, hava örneklerinde bulunan maddelerin mutajenik özelliği olup olmadığını ve bu özelliğin çeşitli faktörlere bağlı değişkenliğinin mikrobioloj ik testlerle gösterilmesidir. Bu çalışmada, 9 bölgede, havadan alman toplam 82 hava örneği (24 tanesi aynı günde çeşitli bölgelerden alınan), 1988/1989 yıllarında toplanıp Ames testinde his- Salmonella typhimurium TA98 ve TalOO suşları kullanılarak ve DNA onarım testinde Escherichiae coli'nin CM611 (uvrA" LexA~ ), CM571 (recA~ ) suşları ile SDS ile işlem görmüş Bacillus thüriıngiensis var. Dendrolimus (p70) 'in ultraviole ışınlarına sensitive suşlarmdan 70f ile 70h vikullanılarak denenmiştir. Yukardakine ek olarak rüzgar hızı ve sıcaklık 4jibi meteorolojik parametrelerle hava kirliliği parametreleri (Kükürt dioksit, duman ve havada asılı parçacıklar) mutajenisiti ve DNA onarım deneylerinin sonuçları ile ilgilendirilmiştir. Korrelasyon ve T-testi analizleri uygulanarak yapılan istatistiksel değerlendirmelerden çıkan sonuçlar aşağıdadır. Muta j enik aktivitenin bölgeler arasında korrelasyon göstermesi, kirliliğin bölgesel olmadığını, yayılma özelliğinin varlığını belirtmiştir. Çalışmada, rüzgar hızı, sıcaklık ve muta j enik aktivite arasında ilişki gözlenmiştir. Muta j enik aktivite hava kirliliği parameterleri ile (toplam asılı parçacıklar, duman ve kükürtdioksit) ilişkili bulunmuştur. TA98 ve TA100 suşları hava örneklerine karşı farklı cevaplar vermiştir. DNA onarım testinde de bakteri suşları aynı hava örneklerine karşı farklı cevaplar vermiştir.Ankaradaki havanın muta j enik değerler açısından dünyadaki diğer kirli şehirlerle karşılaştırıldığında düşük ile orta seviye arasında bir durumda olduğu ortaya çıkmıştır. Kış aylarında mutajenik aktivite daha fazla olmuştur. Direkt-etkisi olan muta je nlerin kaynağının ısınmadan dolayı ortaya çıkan yanık organik maddelerle eksoz atıklarından dolayı olabileceği anlaşılmıştır. S'

Özet (Çeviri)

ABSTRACT Assessment of Air Pollution in ANKARA With The Use of Microbiological Methods Ascxoglu, CANAN M.S. in BIOLOGY Supervisor: Prof. Dr. Hasan BA?CI February 1991,54 Pages Many studies indicate that aerosols in the ambient atmosphere have mutagenic properties. Most of the investigations were conducted in industrial or urban areas or near specific sources. The purpose of our study was to assess the presence and the variation in mutagenicity of airborne particulate matter by using microbiological short-term tests. For this purpose airborne extracts of 82 samples 24 of which were simultaneously taken at 9 sites in Ankara over 1988/1989 period were assayed in the Ames reversion test with his. Salmonella typhimurium strains TA98, TA100 and in a DNA repair test with Escherichiae coli strains CM611 (repair-deficient, uvrA, LexA~ ), CM571 (repair-deficient, recA ) and with SDS-derivatives xxxof Bacillus thurtngiensis var. Dendrolimus ultraviolet sensitive strains 7 Of and 7 Oh. In addition to measured air pollution parameters, wind velocity and temperature values obtained from local meteorological institute were also used in correlation analysis with mutagenicity and DNA repair test. Statistical evaluations of the data using correlation and Students1 T-test analysis led to the fallowing conclusions. Mutagenicity was positively correlated between locations, pointing to large-scale processes and not to local sources. In the present study a relation between wind velocity, temperature, air pollution components (TSP, Smoke, SO2) and mutagenicity was established. The response of the tester strains TA98 and TA100 to air extracts were different. The response of the DNA-repair strains CM611, CM571, 7 Oh, and 7 Of were again different within themselves. The mutagenic activity of air extracts in Ankara's air can be characterized as light to moderate if compared IVto the corresponding levels of other polluted cities of the world. Higher values of mutagenicity were found during winter months. The main source of direct-acting mutagens seem to be the residental heating and traffic exhaust. Key Words : Air pollution, Mutagens, Ames test, DNA repair test, Salmonella typhimurium, Bacillus thyningiensis, Escherichiae coli.

Benzer Tezler

  1. Polivinil klorür (PVC) geri dönüşüm tesisinin yangın güvenliği ve fine kinney analiz metodu ile yangın riskinin değerlendirilmesi

    Fire safety of polyvinyl chloride (PVC) recycling facility and assessment of fire risk using fine kinney analysis method

    ALİ ZEYNELGİL

    Yüksek Lisans

    Türkçe

    Türkçe

    2024

    KimyaSakarya Üniversitesi

    Yangın ve Yangın Güvenliği Anabilim Dalı

    PROF. DR. MUSTAFA ŞAHİN DÜNDAR

  2. Life cycle assessment of building materials in hotel refurbishment projects: A case study in Ankara

    Ankara'daki bir çalışma baz alınarak yenileme projelerindeki bina malzemelerinin hayat döngülerinin değerlendirilmesi

    AYŞEM BERRİN ÇAKMAKLI

    Doktora

    İngilizce

    İngilizce

    2007

    EnerjiOrta Doğu Teknik Üniversitesi

    Mimarlık Ana Bilim Dalı

    DOÇ. DR. SOOFİA TAHİRA ELİAS ÖZKAN

  3. Türkiye'nin endüstri ve ısınma kaynaklı emisyon envanterinin grid sistemine aktarılması ve EMEP ile EDGAR verileriyle mukayesesi

    Transferring the industrial and heating source emissions inventory of Turkey to grid system and comparison with EMEP and EDGAR data

    ZEYNEP AKGÜL

    Yüksek Lisans

    Türkçe

    Türkçe

    2018

    Çevre Mühendisliğiİstanbul Teknik Üniversitesi

    Çevre Mühendisliği Ana Bilim Dalı

    PROF. DR. KADİR ALP

  4. Tarım ve hayvancılık kaynaklı metan emisyonlarının TROPOMI metan ölçümleri ile incelenmesi

    Assessment of methane emissions from agriculture and livestock with TROPOMI methane observations

    EDA CEYLAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2019

    Çevre Mühendisliğiİstanbul Teknik Üniversitesi

    Çevre Mühendisliği Ana Bilim Dalı

    DOÇ. DR. BURÇAK KAYNAK TEZEL

  5. Enerji etkin bina tasarımında ısıtma enerjisi harcamalarını azaltmaya yönelik bir iyileştirme çalışması

    A study to reduce heating energy consumption in energy efficient building design

    AYÇA GAZİOĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    2012

    Enerjiİstanbul Teknik Üniversitesi

    Mimarlık Ana Bilim Dalı

    DR. ŞULE FİLİZ AKŞİT

    YRD. DOÇ. DR. GÜLTEN MANİOĞLU