Geri Dön

Geniş madde kaybı olam posterior dişlerde uygulanan onley restorasyonlarının kırılma direncinin in vitro olarak incelenmesi

Fracture resistance of extensive onlay restorations: An in vitro study

  1. Tez No: 164047
  2. Yazar: NİHAN ÖZLEM HIZIR
  3. Danışmanlar: PROF.DR. DENİZ GEMALMAZ
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2005
  8. Dil: Türkçe
  9. Üniversite: Marmara Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

1. ÖZET Bu çalışmanın amacı; geniş madde kaybı olan, iki farklı preparasyon dizaynı ile hazırlanan ve rezin ve rezin modifiye cam iyonomer siman ile yapıştırılan, maksiller premolar dişlere uygulanan porselen ve seromer (IPS Empress II, SR Adoro) onley restorasyonlarının kırılma direncini incelemektir. Çalışma için 54 adet maksiller premolar 9 gruba ayrıldı. Bir grup kontrol amacı ile ayrılarak deney gruplarındaki dişlere gütaperka ve rezin bazlı bir kanal patı ile kanal tedavisi uygulandı. Dişler akrilik rezin kalıplara mine-sement sınırının 2 mm aşağısında yerleştirildi. Diş preparasyonları paralelometre rehberliğinde yapıldı ve kanal ağızları cam iyonomer ile kapatıldı, tik dört deney grubunda preparasyonlar, mine-sement sınırının 1 mm yukarısında düz bitim sınırı ile bitirilirken 5-8. gruplarda ise 3 mm koronal diş dokusu bırakılarak, bukkolingual olarak 3 mm genişliğinde MOD kaviteler hazırlandı. Her iki preparasyon gruplarında da örnekler iki alt gruba ayrılarak porselen ve seromer onleyler hazırlandı. 1., 2., 5. ve 6. gruplar, Variolink II-High viscosity (Vivadent, Schaan, Liechteinstein) rezin siman ile; 3., 4., 7. ve 8. gruplardaki örnekler ise Fuji Plus Capsule (GC, Tokyo, Japan) rezin modifiye cam iyonomer siman ile simante edildi. Örnekler 5-55 C°'de 15 sn süre ile 3000 ısısal çevirim işlemine tabi tutuldu, 0,5 mm/dak hızla kırılana kadar yüklendi. İstatistiksel analiz için tek yönlü varyans analizi ve Tukey karşılaştırma testi kullanıldı. 1. preparasyon dizaynı 2.'den daha dayanıklı bulunurken yapıştırıcı ajana bağlı fark belirlenmedi. Kontrol grubuna nazaran porselen ve seromer onleylerin kırılma direnci anlamlı derecede yüksek bulundu. Seromer onleylerde daha çok katastrofik kırık (%58,33), tam seramik onleylerde üstyapı kırıkları (%50) ve vertikal yönlü kırıklar (%33,33) gözlendi.

Özet (Çeviri)

2. SUMMARY FRACTURE RESISTANCE OF EXTENSIVE ONLAY RESTORATIONS: AN IN VITRO STUDY The aim of this study was to compare the fracture resistance of extensively damaged maxillary premolars with two different preparation designs, using two different restorative materials (IPS Empress II, SR Adoro), luted with resin and resin modified glass ionomer luting cements. 54 maxillary premolar teeth, were divided into 9 groups. One group of teeth was saved as control and endodontic treatment were performed with gutta percha and resin sealer. The teeth were fixed in autopolymerizing resin blocks 2 mm below the CEJ and prepared using a surveyor. Canal orifices were capped with glass ionomer cement. Groups 1-4 were prepared with butt joint design 1 mm above the CEJ, groups 5-8 were prepared with 3 mm coronal tooth structure and an MOD cavity that has 3 mm width. All samples were divided into two subgroups, porcelain and ceromer onlays were fabricated. The restorations in groups 1-2, 5-6 were cemented with Variolink II-High viscosity (Vivadent, Schaan, Liechtenstein), in groups 3-4, 7-8 Fuji Plus Capsule (GC, Tokyo, Japan) was used for cementation. Teeth were thermocycled between 5-55 C°x3000 cycles and were loaded with a crosshead speed of 0,5 mm/min until fracture. Statistical analyses were performed using the Variance Analysis and the Tukey's Multiple-Range Test. First preparation design was more fracture resistant than second, and cement didn't exhibit a significant difference. Porcelain and ceromer onlays' fracture strength were significantly higher than control group. Ceromer onlays showed catastrophic failures (%58,33) while porcelain onlays showed veneered porcelain fractures (%50) and vertical fractures (%33,33).

Benzer Tezler

  1. Atherosklerotik kalp hastalıklarında risk faktörleri

    Risk factors in the coronary artery disease

    MURAT SUHER

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1987

    Gazi Üniversitesi

    İç Hastalıkları Ana Bilim Dalı

    Yükleniyor...

  2. Nükleer rezonasta moleküler yapıların incelenmesi (yapısal faz geçiş kuramları üzerine bir inceleme)

    Başlık çevirisi yok

    ABDURRAHMAN ANDİÇ

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Uludağ Üniversitesi

    Fizik Ana Bilim Dalı

    Yükleniyor...

  3. Eksternal etmoidektomiler

    Başlık çevirisi yok

    ERCÜMENT AKMAN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1987

    Gazi Üniversitesi

    Kulak Burun Boğaz Ana Bilim Dalı

    Yükleniyor...

  4. Pre-eklampsi ve eklampsi vakalarında immünoglobülin düzeylerinin değerlendirilmesi (Klinik ve immünobiolojik araştırma)

    Examination des valeurs d'immunoglobulines en cas de la toxemie gravidique

    M. MURAT SEMİZ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1987

    Gazi Üniversitesi

    Kadın Hastalıkları ve Doğum Ana Bilim Dalı

    Yükleniyor...

  5. Samsun ve çevresinde tarla sarmaşığı (conuolvulus arvensis L.)'na karşı biyolojik savaşa esas olacak fauna tespiti

    Investigations on the insect fauna of the field binweed (Conuolvulus arvensis L.) related to its biological control in Samsun Province

    YASEMİN UFUK GERMAN

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Bitki Koruma Ana Bilim Dalı

    Yükleniyor...