Geri Dön

Atık sulardan fenol ve türevlerinin biyolojik yöntemlerle gideriminin incelenmesi

The investigation of removal of phenol and derivatives from wastewater by biological methods

  1. Tez No: 177066
  2. Yazar: İLKNUR GÜLER
  3. Danışmanlar: PROF. DR. HANİFE BÜYÜKGÜNGÖR
  4. Tez Türü: Yüksek Lisans
  5. Konular: Biyoteknoloji, Çevre Mühendisliği, Biotechnology, Environmental Engineering
  6. Anahtar Kelimeler: Biyosorpsiyon, fenol, 2-klorofenol, 4-klorofenol, Aspergillus niger, Biosorption, phenol, 2-Chlorophenol, 4-Chlorophenol, Aspergillus niger
  7. Yıl: 2008
  8. Dil: Türkçe
  9. Üniversite: Ondokuz Mayıs Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Çevre Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 154

Özet

Alıcı ortam için 1 µg/l gibi düşük konsantrasyonda bile oldukça toksik bir madde olan fenol ve türevlerinin, endüstriyel atıksulardan ileri bir arıtım yöntemi olan biyosorpsiyon yöntemiyle giderimi üzerine farklı parametrelerin etkilerini incelemek amacıyla ayrıntılı bir çalışma yürütülmüştür. Demir-çelik endüstrileri, petrol, pestisit, boya, çözücü, ve diğer kimyasal proses endüstrilerinin en önemli hammaddelerinden olan fenol ve türevlerinin Aspergillus niger ile biyosorpsiyonu incelenmiştir.Bu çalışmanın amacı, sucul ortamlardan fenol, 2-klorofenol (2-KF) ve 4-klorofenolü (4-KF) gidermek için biyolojik materyal olarak canlı A. niger'in kullanım potansiyelini belirlemektir. Fenol, 2-KF ve 4-KF' ün biyosorpsiyonu üzerine biyokütle konsantrasyonu, başlangıç pH'ı, başlangıç fenol ve klorofenol konsantrasyonu, sıcaklık ve temas süresi gibi deneysel parametrelerin etkileri araştırılmıştır.Arıtım sonucunda fenol ve 2-KF 48 saat içinde dengeye ulaşırken 4-KF 96 saatlik biyosorpsiyon işleminden sonra dengeye ulaşmıştır. Denge sonunda her üç bileşik için de düşük kirletici konsantrasyonlarında % 90'nın üzerinde giderim verimine ulaşılmıştır. Fenol, 2-KF ve 4-KF biyosorpsiyonu için Langmuir ve Freundlich izoterm modelleri analiz edilmiştir ve Langmuir izoterm modelinin biyosorpsiyonu en iyi tanımlayan model olduğu bulunmuştur.Çalışma sonucunda elde edilen verilere göre başlangıç pH'sı, A. niger konsantrasyonu, başlangıç fenol ve klorofenol konsantrasyonu ve sıcaklık giderim verimi için çok önemli parametrelerdir. Kesikli sistem çalışmalarının sonucunda doğal pH da, 10 g/l mikroorganizma konsantrasyonunda, fenol için 28ºC, 2-klorofenol ve 4-klorofenol için ise 45ºC sıcaklıkta en yüksek biyosorpsiyon hızları elde edilmiştir.Sürekli sistemde yapılan kolon çalışmaları sonucunda sistemin kısa sürede doygunluğa ulaştığı ve fenol giderim veriminin kesikli sistemde yapılan çalışmalara kıyasla çok düşük olduğu görülmüştür.

Özet (Çeviri)

A detailed study was conducted to investigate the effects of the parameters on the removal of phenol and its derivatives, which are very toxic to the receiving environment even in low quantities as 1 µg/l from industrial wastewater via biosorption method which are sophisticated treatment methods. Biosorption of phenol and its derivatives- one of the most important raw materials for the industries such as iron and steel, petroleum, pesticide, paint, solvent and other chemicals process- via A. niger was investigated.The aim of this study is to determine the usage potential of the live A. niger as biological material for the removal of phenol (Ph), 2-chlorophenol (2-CP) and 4-chlorophenol (4-CP) from aquatic mediums. The effects of experimental parameters such as biomass concentration, the initial pH, initial phenol and chlorophenol concentration, temperature and contact time on the biosorption of Ph, 2-CP and 4-CP were investigated.After the treatment process, it is found out that Ph and 2-CP reached equilibrium in 48 hour, where as 4- CP reached equilibrium following a 96 hour biosorption time. At the end of the equilibrium, a 90 % removal efficiency was obtained for each of the three compounds at the low contaminant concentrations. Langmuir and Freundlich isotherm models were analyzed for biosorption of Ph, 2-CP and 4-CP and it was found that Langmuir isotherm model was the best model for the biosorption.The data obtained in this study show clearly that the initial pH, A. niger concentration, the initial phenol and chlorophenol concentration and temperature are very important parameters for the removal efficiency. As a result of a batch system study, it is found out maximum biosorption rate for 2-CP at 450C and for 4-CP at 280C at for phenol at 10 g/l microorganism concentration at natural pH were obtained.After column studies which made in the continuous system, it was found that system reached saturation at short time and phenol removal efficiency very low became than made at a batch system.

Benzer Tezler

  1. Grafting of poly(acrylamide) onto crosslinked poly(HEMA-co-MMA) resin for removal of phenol and bisphenol A

    Poli(akrilamid)'in çapraz bağlı poli(HEMA-co-MMA) reçineye aşılanması ve fenol ile bisfenol A 'nın giderilmesinde kullanılması

    HANDAN USTA

    Yüksek Lisans

    İngilizce

    İngilizce

    2016

    Polimer Bilim ve Teknolojisiİstanbul Teknik Üniversitesi

    Polimer Bilim ve Teknolojisi Ana Bilim Dalı

    PROF. DR. BAHİRE FİLİZ ŞENKAL

  2. Cu-Ti-sütunlu zeolit kullanarak atıksulardan fenol gideriminin araştırılması

    Investigation of phenol removal from wastewater using Cu-Ti-pilc zeolite

    BURAK İLERİ

    Yüksek Lisans

    Türkçe

    Türkçe

    2020

    Çevre MühendisliğiSakarya Üniversitesi

    Çevre Mühendisliği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ BEYTULLAH EREN

    PROF. DR. ABDİL ÖZDEMİR

  3. Atık sularda fenolik kirliliklerin giderilmesi için kitosan kaplı manyetik nano boyutlu katı ekstraktant hazırlanması ve karakterizasyonu

    Preparation and characterization of chitosan coated magnetic solid extractant of nanosize for the removal of phenolic pollution i̇n wastewater

    ERDAL ERTAŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    2015

    KimyaDicle Üniversitesi

    Kimya Ana Bilim Dalı

    DOÇ. DR. BİLSEN TURAL

  4. Cibacron blue F3GA takılı magnetik phema ile atık sularda bulunan fenol ve nitrofenol türevlerinin uzaklaştırılması

    Removal of phenols and nitrophenols from aquatic system using cibacron blue F3GA attached mphema

    KÜBRA ÖZDİLEK

    Yüksek Lisans

    Türkçe

    Türkçe

    2009

    KimyaAfyon Kocatepe Üniversitesi

    Kimya Ana Bilim Dalı

    YRD. DOÇ. DR. MUSTAFA UÇAR

  5. Atık sulardan fenolik bileşiklerin uzaklaştırılması için yeni nesil destek malzemeleri

    Novel materials for removal of phenolic compounds from waste water

    TUĞBA DOĞAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2014

    KimyaHacettepe Üniversitesi

    Kimya Ana Bilim Dalı

    PROF. DR. SERAP ŞENEL