Pulslu ve pulssuz perfüzyonun oksijenatör fiberi üzerine etkilerinin araştırılması
Investigation of the effects of pulsatile and non-pulsatile perfusion on oxygenator fibers
- Tez No: 182297
- Danışmanlar: DOÇ.DR. HAKAN AYHAN
- Tez Türü: Yüksek Lisans
- Konular: Biyomühendislik, Bioengineering
- Anahtar Kelimeler: Pulslu akış, ekstrakorporal dolaşım, biyouyumluluk, Pulsatile flow, extracorporeal circulation, biocompability
- Yıl: 2006
- Dil: Türkçe
- Üniversite: Hacettepe Üniversitesi
- Enstitü: Fen Bilimleri Enstitüsü
- Ana Bilim Dalı: Biyomühendislik Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: 101
Özet
Açık kalp ameliyatlarında hastalar pulslu ve pulssuz olmak üzere iki şekildeperfüze edilebilmektedir. Pulslu akışın, pulssuz akışa göre sahip olduğu yüksekenerjinin hastaya ve oksijenatör fiberine farklı etkileri olabilmektedir. Özellikleperfüzyon tipinin oksijenatör fiberine üzerine etkileri tam olarak bilinmemektedir.Sunulan bu çalışmanın amacı pulslu ve pulssuz perfüzyonun oksijenatör fiberineüzerine etkilerinin araştırılmasıdır. Bu etkilerin araştırılması için pediatrik açık kalpameliyatı geçiren 32 hastadan 18'i uygun aortik çapraz kıskaç sürelerine göreseçilerek çalışmaya dahil edilmiştir. Çalışmaya dahil edilen 9 çocuk hastayapulslu, 9 çocuk hastaya pulssuz perfüzyon uygulanmış, kardiyopulmoner bypasöncesi, aorta çapraz kıskaç ile kapatıldığında ve açıldığında, yoğun bakım 1.saatte ve 24. saatte olmak üzere 5 ayrı zaman diliminde tam kan ve plazmaproteinleri ölçümlerinin karşılaştırılması için hasta kanları toplanmıştır. Açık kalpameliyatı sonlandığında ve hastanın yaşamsal belirtileri sabitlendiğinde, kullanılanvücut dışı dolaşım devresinde oksijenatör çıkartılmış, fiber bölgesinden 10 cm'likfiber parçaları alınarak serum fizyolojik çözeltisine konmuştur. Fiberlerinbulunduğu bu çözeltide tazelenen ve sonikasyon işlemine tabi tutulan yeniçözeltide tam kan ve mikro-protein ölçümleri yapılmıştır. Hasta sonuçlarına görepulslu perfüzyonun kan hücrelerine ve plazma proteinlerine olumsuz bir etkisigörülmemiştir. Fiber sonuçlarına bakıldığında sonike edilmiş fiberlerde pulssuzgrupta bir miktar daha fazla eritrosit, lökosit ve total protein yüzeye tutunmasıtespit edilmiştir. Pulslu perfüzyon daha iyi kan uyumluluğu sağlamış ve sahipolduğu yüksek enerjiyle daha iyi mikrodolaşım yaratmıştır.
Özet (Çeviri)
In cardiopulmoner operations patients can be perfused with a pulsatile ornonpulsatile pump mode. The extra energy maintained by the pulsatile perfusionmay have different effects on the patient and the oxygenator fiber rather thannonpulsatile perfusion. Especially the effect of pulsatile perfusion on the fibers isn?tclearly known. The purpose of this study is to investigate the effects of pulsatileand non-pulsatile blood flows on oxygenator fibers. 18 out of 32 patients that hadan pediatric open heart surgery was chosen according to their aortic clamp times.9 of 18 patients were perfused in a pulsatile mode, other 9 patients were perfusedin a nonpulsatile mode. The patient blood was collected before the open heartsurgery(T1), before aortic clamp (T2), after aortic clamp(T3), after 1st intensivecare hour(T4) and after the 1st intensive care day (T5) in order to compare theresults of whole blood and plasma proteins. At the end of the open heart operation10 cm of oxygenator fiber was removed from the fiber bundle and taken into 10ccNaCl solution after the patient had a stabile outcome. Whole blood and microprotein measurements were applied in both first fiber solution and sonicatedsolution. No harmful effect of pulsatile perfusion on blood cells and proteins wasobserved according to patient results. More blood cell aggregation and totalprotein adsorption was observed in nonpulsatile mode fibers. In this study pulsatileperfusion maintained better biocompability over nonpulsatile perfusion. The extraenergy in pulsatile perfusion caused better microcirculation.
Benzer Tezler
- Pulslu ve pulssuz akışın kaplamalı oksijenatörlerde biyouyumluluğa etkisinin sem (taramalı elektron mikroskop) ile incelenmesi
Investigation of the effects of pulsatile and non-pulsatile perfusion on oxygenator fibers with sem (scanning electron microscop)
ECE ÜRPERMEZ
Yüksek Lisans
Türkçe
2013
Bilim ve TeknolojiBaşkent ÜniversitesiBiyomedikal Mühendisliği Ana Bilim Dalı
DOÇ. DR. MUSTAFA KOCAKULAK
- Pulsatile akışın heparin kaplı oksijeneratör ile biyouyumluluğunun araştırılması
Investigation of the biocompatibility of the pulsatile blood flow with heparin coated oxigenator
TUNA GÜRAY
Yüksek Lisans
Türkçe
2013
BiyomühendislikBaşkent ÜniversitesiBiyomedikal Mühendisliği Ana Bilim Dalı
DOÇ. DR. MUSTAFA KOCAKULAK
- Açık kalp cerrahisinde pulslu perfüzyonun erken dönem etkileri
Short term effects of pulsatile perfusion in open heart surgery
MUSTAFA KOCAKULAK
Doktora
Türkçe
2001
BiyomühendislikHacettepe ÜniversitesiBiyomühendislik Ana Bilim Dalı
PROF. DR. ERHAN PİŞKİN
DOÇ. DR. SÜHA KÜÇÜKAKSU
- Pulslu akışta poliakrilonitril diyaliz zarlarındaki kütle aktarımına puls frekansı ve faz oranının etkisi
Başlık çevirisi yok
FATMA KORMALI BAYRAMOĞLU
Yüksek Lisans
Türkçe
1983
Kimya MühendisliğiHacettepe ÜniversitesiKimya Mühendisliği Ana Bilim Dalı
DOÇ.DR. AHMET ÖZDURAL
- Karbon keçe elektrodlarda sınırlayıcı akım tekniği ile kütle transferi
Mass transfer in carbon felt electrodes by limiting current technique
ERTUĞRUL ERKOÇ
Yüksek Lisans
Türkçe
1999
Kimya MühendisliğiAtatürk ÜniversitesiKimya Mühendisliği Ana Bilim Dalı
PROF. DR. SİNAN YAPICI