Dört farklı dalga formunu destekleyen bir elektroakupunktur stimülatör tasarımı ve gerçekleştirilmesi

The design and performance of an electroacupuncture stimulator supporting four different waveforms

  1. Tez No: 183131
  2. Yazar: LOKMAN HİKMET TEKİN
  3. Danışmanlar: Y.DOÇ.DR. SALİH GÜNEŞ
  4. Tez Türü: Yüksek Lisans
  5. Konular: Elektrik ve Elektronik Mühendisliği, Fiziksel Tıp ve Rehabilitasyon, Fizyoloji, Electrical and Electronics Engineering, Physical Medicine and Rehabilitation, Physiology
  6. Anahtar Kelimeler: Akupunktur, Elektroakupunktur, elektroterapi, uyartım, Stimülatör, fonksiyon jeneratörü, frekans, gerilim, mikrodenetleyici, zamanlayıcı, Stimulator, function generator, frequency, voltage, microcontroller, timer
  7. Yıl: 2006
  8. Dil: Türkçe
  9. Üniversite: Selçuk Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Elektrik-Elektronik Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 130

Özet

ÖZETYüksek Lisans TeziDÖRT FARKLI DALGA FORMUNU DESTEKLEYENB R ELEKTROAKUPUNKTUR ST MÜLATÖRTASARIMI VE GERÇEKLEŞT R LMESLokman Hikmet TEK NSelçuk ÜniversitesiFen Bilimleri EnstitüsüElektrik-Elektronik Mühendisliği Anabilim DalıDanışman: Yrd. Doç. Dr. Salih GÜNEŞ2006, 68 sayfaJüri : Yrd. Doç. Dr. Salih GÜNEŞYrd. Doç. Dr. Ercan YALDIZYrd. Doç. Dr. Nihat YILMAZBu çalışmada, düşük frekanslarda değişik dalga şekillerinin insan vücudundakietkilerinin incelenmesine yönelik tıbbi araştırmalarda kullanılmak üzere birElektroakupunktur Stimülatör cihazı tasarlanmış ve gerçekleştirilmiştir. GerçekleştirilenElektroakupunktur Stimülatör cihazı, istenilen 1-260 Hz, 0-4000 mV aralığındaki frekans vegerilim değerlerindeki sinüs, kare, üçgen, testeredişi sinyallerinden herhangi birisini 100dakikaya kadar ayarlanan süre boyunca sürekli olarak verebilme özelliğine sahiptir. Cihaz,mikrodenetleyici ve buna bağlı olarak çalışan giriş-çıkış ünitesi, dijital analog konvertör(DAC) ünitesi, LCD ekran ünitesi, zamanlayıcı (timer) ve yükselteç (amplifikatör) ünitesiolmak üzere 6 bileşenden meydana gelmektedir.Yine bu proje kapsamında, cihaz tarafından üretilen sinyallerin değişik gerilim vefrekans değerlerindeki osiloskop görüntüleri ve etalon cihazla gerçekleştirilen ölçüm sonuçlarıverilerek, piyasada benzer amaçla kullanılan 6 farklı cihaz ile avantaj ve dezavantajlarınailişkin karşılaştırması yapılmıştır. Üretilen sinyaller son derece kararlı ve düzgün olup tümgerilim değerlerindeki frekans hassasiyeti % 0.1- 4 aralığında değişim göstermektedir.

Özet (Çeviri)

ABSTRACTMaster ThesisTHE DESIGN AND PERFORMANCE OFAN ELECTROACUPUNCTURE STIMULATORSUPPORTING FOUR DIFFERENT WAVEFORMSLokman Hikmet TEK NSelcuk UniversityGraduate School of Natural and Applied SciencesDepartment of Electrical-Electronics EngineeringSupervisior: Asst. Prof. Dr. Salih GÜNEŞ2006, 68 pages: Asst. Prof. Dr. Salih GÜNEŞJuryAsst. Prof. Dr. Ercan YALDIZAsst. Prof. Dr. Nihat YILMAZIn this study, an Electroacupuncture stimulation device has been designed andperformed to be used in the medical researches related to examination of the effects of variouswaveforms with low frequency on human body. This designed Electroacupuncture Stimulatordevice is able to provide continous sinus, square, triangle and sawtooth signals in the range of1-260 Hz frequency and 0-4000 mV voltage for a period of adjustable time up to 100 minutes.The device consists of 6 components including a microcontroller, an input-output unit,a digital analog convertor (DAC), a liquid crystal display (LCD) unit, a timer unit andan amplifier unit.Also in the study, a comparison of designed device and 6 other devices, those areused in the market for the same objective, has been performed based on the advantages anddisadvantages by providing the osciloscope outputs and measurement results, those areperformed by reference device, of the signals of designed device at various voltage andfrequency values. The generated signals are consistent and the frequency precise ranges0.1-4.0 % at all voltage values.Acupuncture, Electroacupuncture, electrotherapy, stimulation,

Benzer Tezler

  1. A study of D26-D3 strings and anyon states

    D26-D3 sicimler üzerine bir çalışma ve anyon durumları

    BİLGE KAĞAN BÖREKÇİ

    Yüksek Lisans

    İngilizce

    İngilizce

    2021

    Fizik ve Fizik Mühendisliğiİstanbul Teknik Üniversitesi

    Fizik Mühendisliği Ana Bilim Dalı

    DOÇ. DR. MEHMET ÖZKAN

  2. Yeni Cami'nin akustik açıdan performans değerlendirmesi

    Evaluation of the acoustical performance of the New Mosque

    EVREN YILDIRIM

    Yüksek Lisans

    Türkçe

    Türkçe

    2003

    Mimarlıkİstanbul Teknik Üniversitesi

    Mimarlık Ana Bilim Dalı

    PROF. DR. SEVTAP YILMAZ DEMİRKALE

  3. Taşınabilir torasik biyoempedans monitör tasarımı

    Portable thoracic bioimpedance monitor design

    OYA KÖKSAL

    Yüksek Lisans

    Türkçe

    Türkçe

    2020

    Mühendislik BilimleriBaşkent Üniversitesi

    Biyomedikal Mühendisliği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ ORHAN ERDEM HABERAL

  4. Dalga formlu parmak frezelerin işleme performanslarının araştırılması

    Investigation of machining performances of the wave form end mills

    KUTAY AYDIN

    Doktora

    Türkçe

    Türkçe

    2021

    Makine MühendisliğiGazi Üniversitesi

    İmalat Mühendisliği Ana Bilim Dalı

    PROF. DR. ULVİ ŞEKER

    PROF. DR. ARİF GÖK

  5. Beşinci nesil dalga formu adaylarında zeki optimizasyon teknikleriyle tepe gücü/ortalama güç oranının düşürülmesi

    Peak-to-average power ratio reduction using intelligent optimization techniques in the fifth generation waveform candidates

    ŞAKİR ŞİMŞİR

    Doktora

    Türkçe

    Türkçe

    2021

    Elektrik ve Elektronik MühendisliğiErciyes Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    PROF. DR. NECMİ TAŞPINAR