RF coil system design for MRI applications in inhomogeneous main magnetic field

Homojen olmayan ana manyetik alanda manyetik rezonans görüntüleme için RF sargısı sistemi tasarımı

  1. Tez No: 201769
  2. Yazar: AYHAN OZAN YILMAZ
  3. Danışmanlar: PROF. DR. MURAT EYÜBOĞLU
  4. Tez Türü: Yüksek Lisans
  5. Konular: Biyomühendislik, Elektrik ve Elektronik Mühendisliği, Radyoloji ve Nükleer Tıp, Bioengineering, Electrical and Electronics Engineering, Radiology and Nuclear Medicine
  6. Anahtar Kelimeler: Manyetik Rezonans G¨or¨unt¨uleme, Rf Sargısı Tasarımı, Homojen Olmayan Ana Manyetik Alan, RF Alanı, Akı Fonksiyonları, Taban Fonsiyonları, Momentler Y¨ontemi, Y¨uzey Akım Yo˘gunlu˘gu, Magnetic Resonance Imaging, Rf Coil Design, Inhomogeneous Main Magnetic Field, Rf Field, Stream Functions, Basis Functions, Method of Moments, Surface Current Density
  7. Yıl: 2007
  8. Dil: İngilizce
  9. Üniversite: Orta Doğu Teknik Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Elektrik ve Elektronik Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 146

Özet

Bu ¸calı¸smada, homojen olmayan ana manyetik alanlarda kullanılmak ¨uzere RF sargısı geometrileri tasarlanmı¸stır. ˙Istenen RF manyetik alan karakterini olu¸sturabilecek akım yo˘gunlu˘gu da˘gılımı, ¨onceden tanımlanmı¸s k¨ubik, silindirik ve d¨uzlemsel y¨uzeylerde Momentler Y¨ontemi kullanılarak elde edilmi¸s, elde edilen akım yo˘gunlu˘gu da˘gılımlarının yarattı˘gı manyetik alanın istenen alana yakla¸stırılması i¸cin Tikhonov, CGLS, TSVD ve Rutisbauer d¨uzenlile¸stirme y¨ontemleri uygulanmı¸s, her bir y¨uzey se¸cimi ve d¨uzenlile¸stirme y¨ontemi i¸cin hesaplanan akım yo˘gunlu˘gunu olu¸sturabilecek iletken ¸sekilleri Akı Fonksiyonları kullanılarak belirlenmi¸stir. Elde edilen akım yo˘gunlu˘gu da˘gılımlarının olu¸sturdu˘gu manyetik alanlar hesaplanmı¸s, hesaplanan alanlar ile olu¸sturulmak istenen alanlar arasındaki hata y¨uzdeleri hesaplanmı¸stır. Hata y¨uzdeleri ve iletken ¸sekillerinin hayata ge¸cirilebilme kolaylı˘gı g¨oz ¨on¨unde bulundurularak; silindirik, k¨ubik ve d¨uzlemsel y¨uzeyler ¨uzerine yerle¸stirilmek ¨uzere optimum iletken ¸sekilleri belirlenmi¸s, bu ¸sekilleri elde etmek i¸cin kullanılması gereken d¨uzenlile¸stirme y¨ontem ve parametreleri belirlenmi¸stir. vi Elde edilen sonu¸clardan d¨uzlemsel y¨uzey i¸cin hesaplanan iletken ¸sekli ger¸cekle¸stirilmi¸s, teorik olarak hesaplanan manyetik alan ile LakeShore 3 Kanallı Gaussmetre kullanılarak ¨ol¸c¨ulen manyetik alan arasında 11 ortalama hata y¨uzdesi elde edilmi¸stir. Ger¸cekle¸stirilen RF sargısının ind¨uktans de˘gerleri ¨ol¸c¨ulm¨u¸s, ayarlama ve e¸sleme kapasit¨or de˘gerleri hesaplanmı¸s, Electronic Workbench 5.1 kullanılarak elde edilen sistem test edilmi¸stir. Test edilen sistemin kalite fakt¨or de˘geri 162.5 olarak belirlenmi¸stir. Bu de˘ger 6.387 MHz'te (ODTU MRG sistemi ¸calı¸sma frekansı) 39.2 KHz'lik bir bant geni¸sli˘gine kar¸sılık gelmektedir. Bu ¸calı¸smada ¨onerilen teknikler kullanılarak homojen olmayan bir ana manyetik alanda kullanılabilecek RF sargıları, ¨onceden tanımlanmı¸s y¨uzeyler ¨uzerinde tasarlanıp ger¸cekle¸stirilebilir. Ayrıca geli¸stirilen sargı sayesinde kalıcı mıknatıs ile yaratılan manyetik alanlar kullanılarak elde uygulanabilecek ta¸sınabilir bir manyetik rezonans g¨or¨unt¨uleme cihazı tasarlanabilir.

Özet (Çeviri)

In this study, RF coil geometries are designed for MRI applications using in-homogeneous main magnetic fields. The current density distributions that can produce the desired RF magnetic field characteristics are obtained on prede-fined cubic, cylindrical and planar surfaces and Tikhonov, CGLS, TSVD and Rutisbauer regularization methods are applied to match the desired and gen-erated magnetic fields. The conductor paths, which can produce the current density distribution calculated for each surface selection and regularization technique, are determined using stream functions. The magnetic fields gen-erated by the current distributions are calculated and the error percentages between the desired and generated magnetic fields are found. Optimum con-ductor paths that are going to be produced on cubic, cylindrical and planar surfaces and the required regularization method are determined on the basis of error percentages and realizability of the conductor paths. The optimum conductor path calculated for the planar coil is realized and in the measurement done by LakeShore 3-Channel Gaussmeter, an average error percentage of 11 is obtained between the theoretical and measured mag-netic field. The inductance values of the realized RF coil are measured; the tuning and matching capacitance values are calculated and the frequency char-acteristics of the system is tested using Electronic Workbench 5.1. The quality factor value of the tested system is found to be 162.5, which corresponds to a bandwidth of 39.2 KHz at 6.387 MHz (operating frequency of METU MRI system). The techniques suggested in this study can be used in order to design and realize RF coils on predefined arbitrary surfaces for inhomogeneous main mag-netic fields. In addition, a hand held MRI device can be manufactured which uses a low cost permanent magnet to provide a magnetic field and generates the required RF field with the designed RF coil using the techniques suggested in this study.

Benzer Tezler

  1. Thin film based semi-active RF marker design for interventional MRI devices

    Girişimsel radyolojide kullanılan cihazlar için ince film tabanlı yarı aktif RF işaretleyici tasarımı

    ENGİN BAYSOY

    Doktora

    İngilizce

    İngilizce

    2018

    BiyomühendislikBoğaziçi Üniversitesi

    Biyomedikal Mühendisliği Ana Bilim Dalı

    DOÇ. DR. ÖZGÜR KOCATÜRK

  2. Design and optimization of a sub-1dB noise figure low noise amplifier for magnetic resonance applications using CMOS technology

    CMOS teknolojisi kullanılarak manyetik rezonans uygulamaları için 1db altında gürültü rakamına sahip düşük gürültülü amplifikatör tasarımı ve optimizasyonu

    AYŞE RANA BAL

    Yüksek Lisans

    İngilizce

    İngilizce

    2024

    Elektrik ve Elektronik Mühendisliğiİhsan Doğramacı Bilkent Üniversitesi

    Elektrik ve Elektronik Mühendisliği Ana Bilim Dalı

    PROF. DR. ABDULLAH ATALAR

  3. A gate modulated digitally controlled modified class-e amplifier for on-coil application in MRI

    MRG'de bobin üzeri uygulama için kapı kiplemeli sayısal kontrollü değiştirilmiş sınıf-e güç yükselteci

    BISMILLAH NASIR ASHFAQ

    Yüksek Lisans

    İngilizce

    İngilizce

    2018

    Elektrik ve Elektronik Mühendisliğiİhsan Doğramacı Bilkent Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    PROF. DR. ERGİN ATALAR

  4. Highly efficient 300 W modified class-E RF amplifiers for 64 MHz transmit array system

    64 MHz verici dizisi sistemi için yüksek verimli 300 W değiştirilmiş class-E RF yükselteci

    FATIMA TU ZAHRA

    Yüksek Lisans

    İngilizce

    İngilizce

    2017

    Elektrik ve Elektronik Mühendisliğiİhsan Doğramacı Bilkent Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    PROF. DR. ERGİN ATALAR

  5. Design and applications of a Z-gradient array in magnetic resonance imaging

    Z-gradyan dizisinin tasarımı ve manyetik rezonans görüntülemedeki uygulamaları

    NİYAZİ KORAY ERTAN

    Doktora

    İngilizce

    İngilizce

    2019

    Elektrik ve Elektronik Mühendisliğiİhsan Doğramacı Bilkent Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    PROF. DR. ERGİN ATALAR