Normal doğumda kontinue epidural analjezi: Lidocaine-bupivacaine kıyaslanması
Başlık çevirisi mevcut değil.
- Tez No: 20304
- Danışmanlar: DR. NEBAHAT SİVRİKAYA
- Tez Türü: Tıpta Uzmanlık
- Konular: Anestezi ve Reanimasyon, Anesthesiology and Reanimation
- Anahtar Kelimeler: Analjezi-epidural, Bupivakain, Doğum, Lidokaine, Analgesia-epidural, Bupivacaine, Delivery, Lidocaine
- Yıl: 1991
- Dil: Türkçe
- Üniversite: Sağlık Bakanlığı
- Enstitü: İstanbul Şişli Hamidiye Etfal Eğitim ve Araştırma Hastanesi
- Ana Bilim Dalı: Belirtilmemiş.
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
ÖZET Tümü multipar 28 olguda yaptığımız bu çalışmada ASA I grubunda yer alan terminde gebelerde serviks 4-5 cm dilate olduğunda tekniğine uygun olarak L3,4 aralığından epidural blok yaptık, kateter yerleştirdik. Kateter aracılığıyla birinci gruba (n=14) % 1 lidocaine, ikinci gruba (n=14) % 0.375 bupivacaine analjezi amacıyla verildi. Kullanılan solüsyonların volümü her iki grupta benzerdi (p>0.5). Gruplar arasında analjezi yeterliliği ve sefalad yayılım arasında fark yoktu (p>0.5). Ek dozlar da volüm olarak biribirileriyle benzerlik göstermekteydi (p>0.5). Analjezi süreleri lidocaine grubunda ilk doz ve ek dozlar arasında ileri derecede anlamlı farklar göstermekteydi (p<0.01). Bupivacaine grubunda ise ek doz etki süreleri çalışmaya alınmadı. Her iki grubun ilk dozları arasında da ileri derecede anlamlı etki süresi etki başlama zamanı farklılıkları ortaya çıktı (p<0.01). Kardiyovasküler sistem etkilerini değerlendirmek amacıyla ölçtüğümüz ortalama arter basınçları ve kalp atım hızları her iki grupta; blok anında, analjezi başlama zamanında, tüm doğum eylemi boyunca ve doğum sonrasında farklılık arz etmedi (0. Kp<0.5). Motor blok, Bromage skalasına göre yapılan değerlendirmede her iki grupta istatistiksel olarak anlamsızdı (0.1< p<0.5).Fetal kalp hızı, tüm doğum eylemleri boyunca normal sınırlarda seyretti. Doğumdan sonra birinci ve beşinci dakika Apgar skorları, grup I'de anlamsız (0.1<p<0.5) bulunurken grup Il'de anlamlı (p<0.01) olarak ölçüldü. İki grup arasında Apgar değerleri istatistiksel olarak anlamsızdı (0.1<p<0.5).
Özet (Çeviri)
- 35 - SUMMARY 28 multiparous parturients were included in this study Epidural catheter was utilized using the L3, 4 level. By using the catether 1% lidocaine was given to group I and 0.375% bupivacaine to group II. The volumes used were similar in both groups (p>0.5). The quality of analgesia and cefalad distriution were also similar (p>0.5). Top up doses were not significant (p>0.5). The duration of analgesia in the lidocaine group was significant for the initial and the repeated doses (p<0.01). The duration of the top up doses in the bupivacaine group was not included in the study. The duration between the groups for the initial doses were significant (p<0.01). The cardiovascular effects were evaluated by calculating the mean arterial pressures, heart rate at the time of the block onset of analgesia, duration of labor and after birth. All the parameters were non significant (0.1<p<0.5). The motor block, evaluated according to the Bromage scale, was nonsignificant between the groups (0.1<p<0.5). The fetal heart rate was within normal limits all through labor. The Apgar scorage was non significant for group I in the first and fifth minutes (0.1<p<0.5). The scores were significant in group II (p<0.01). The scores were nonsignificant between the two groups (0.1<p<0.5).
Benzer Tezler
- Devamlı epidural teknik ile uygulanan % 0.25`lik Bupivakain`in doğum analjezisindeki değerinin incelenmesi
Başlık çevirisi yok
GÜLÇİN OLCAY
Tıpta Uzmanlık
Türkçe
1988
Anestezi ve ReanimasyonAnadolu ÜniversitesiAnesteziyoloji ve Reanimasyon Ana Bilim Dalı
- Ankara ilindeki üç ilköğretim okulu öğrencilerinin epilepsiye yaklaşımı ve hastalık hakkındaki bilgi düzeyleri
Knowledge of epilepsy and attitudes towards the condition among three elementary schools students in Ankara
İKBAL OK BOZKAYA
Tıpta Uzmanlık
Türkçe
2006
Çocuk Sağlığı ve HastalıklarıGazi ÜniversitesiÇocuk Ruh Sağlığı ve Hastalıkları Ana Bilim Dalı
PROF. DR. AYŞE SERDAROĞLU
- Normal doğumda ve sezaryen doğumda anne memnuniyetinin değerlendirilmesi
Assessment of mother satisfaction at vaginal and cesarean birth
ŞADİYE BOZKURT
- Normal doğumda nefes egzersizlerinin doğum travayına etkisi
The effect of breathing exercises to labor duration throughout vaginal delivery
HİLAL YÜKSEL
Tıpta Uzmanlık
Türkçe
2016
Aile HekimliğiAtatürk ÜniversitesiAile Hekimliği Ana Bilim Dalı
DOÇ. DR. YASEMİN ÇAYIR