Elektron demet tedavilerinde doku heterojenitelerinin ve yüzey düzensizliklerinin doz dağılımına etkisi

Effect of tissue heterogeneities and surface irregularities on dose distrubition in electron beam therapy

  1. Tez No: 210550
  2. Yazar: SÜREYYA YILDIZ
  3. Danışmanlar: PROF.DR. DOĞAN BOR
  4. Tez Türü: Yüksek Lisans
  5. Konular: Fizik ve Fizik Mühendisliği, Onkoloji, Physics and Physics Engineering, Oncology
  6. Anahtar Kelimeler: Elektron, Electron
  7. Yıl: 2007
  8. Dil: Türkçe
  9. Üniversite: Ankara Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Fizik Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmada Onko Ankara Onkoloji merkezinde bulunan Siemens Primus Mid Energy M5006 lineer hızlandırıcı cihazının 5, 7, 8, 10, 12 ve 14 MeV enerjili elektron demetleri kullanılarak, elektron demetlerinin dokuda soğurulmasında doku heterojenitesinin etkisi ve elektron demetlerinin değişen gantri açılarında %DD eğrileri incelendi. Daha sonra elde edilen sonuçlar yardımıyla göğüs duvarı ve baş-boyun boost ışınlaması tedavi planlamaları yapıldı. Yapılan tedavi planlamaları için TPS ortamında doz-hacim histogramları elde edildi. Belli bölgelerin aldığı dozların planlama sistemiyle uyumu, randofantom ve TLD-100 ile yapılan ölçümlerle sağlandı. Sonuç olarak E = 5 ve 7 MeV enerjili elektron demetleri ile yapılan göğüs duvarı ışınlaması ve E = 10 MeV enerjili elektron demetleri ile yapılan baş-boyun boost ışınlaması için elde edilen TPS doz değerleri ile rando fantom ışınlaması sonucu elde edilen ortalama TLD doz değerleri kıyaslandığında aradaki farkın % ± 3 sınırları içerisinde olduğu gözlendi.

Özet (Çeviri)

In this study, Siemens Primus Mid Energy M5006 linear accelarator at ONKO Ankara Onkoloji Center using 5, 7, 8, 10, 12 ve 14 MeV energy electron beams and were utilized. All measurements were obtained with phantom equalence of human. Effect of tissue heterogeneities and surface irregularities on dose distrubition and increasing value of gantry % PDD slope was investigated in electron beam therapy. Head and neck boost and chest-wall irradiated were planned by the results. DVHs (Dose volume histogrames) were obtained in TPS ( Treatment Planning Systems) for these planning. The dose and planning system harmony in the specified area was obtained by TLD-100 measurements. In conclusion, the difference between TPS dose values that were obtained for head and neck boost planning with 5 and 7 MeV electron beams and chest-wall irradiated planning with 10 MeV electron beams and TLD-100 measurements values were within ±3%.

Benzer Tezler

  1. Plazma arkı eldesi ve yüzey bölgesi modifikasyonunda kullanılabilirliği

    Başlık çevirisi yok

    ÖZKAN ÖZİPEKLİLER

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Uludağ Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  2. Pik demiri ve karbon çeliğinin sulu çözeltiler içindeki korozyon hızının tayini

    Determination of the rate of corrosion of the cast iran and carbon steel in the aqueous solutions

    EMİNE NAZAN ÜNAL

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Gazi Üniversitesi

    Kimya Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  3. Çok ince yapı teorisi

    Theory of hyperfine structure

    ŞEMSETTİN ALTINDAL

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Gazi Üniversitesi

    Yükleniyor...