Biyolojik arıtılabilirlik bazlı atık su karakterizasyonu ve atık aktif çamur üzerinde ozonlamanın etkisi
Effect of ozonation on biodegradability oriented wastewater characterization and on surplus activated sludge
- Tez No: 223724
- Danışmanlar: PROF.DR. FATOŞ GERMİRLİ BABUNA
- Tez Türü: Doktora
- Konular: Biyoteknoloji, Çevre Mühendisliği, Biotechnology, Environmental Engineering
- Anahtar Kelimeler: Atık Aktif Çamur, Biyolojik Ayrışabilirliğin İyileştirilmesi, Çamur Dezentegrasyonu, Deri Endüstrisi Atıksuları, KOİ Fraksiyonasyonu, Ozonlama, Respirometrik Ölçümler, Surplus Activated Sludge, Biodegradability Improvement, Sludge Disintegration, Tannery Wastewater, COD Fractionation, Ozonation, Respirometric Measurements
- Yıl: 2006
- Dil: Türkçe
- Üniversite: İstanbul Teknik Üniversitesi
- Enstitü: Fen Bilimleri Enstitüsü
- Ana Bilim Dalı: Çevre Mühendisliği Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: 261
Özet
Bu çalışmanın birinci ayağında, biyolojik arıtma sırasında ozonla kimyasal oksidasyon işlemi için optimum ozonlama noktasının belirlenmesi araştırılmıştır. Deri endüstrisi atıksuyu numunelerinde yürütülen deneylerde; ön ozonlama prosesinde, ozonlama işleminin biyolojik açıdan daha kolay ayrışabilir niteliğe dönüştürülmesi istenen çözünmüş ve partiküler inert organik madde üzerinde herhangi bir etki yaratmadığı ve biyolojik arıtma ile rekabet edici şekilde çalıştığı saptanmıştır. Biyolojik ? kimyasal ? biyolojik şeklinde sıralanan biyolojik oksidasyon sırasında kimyasal oksidasyon işlemi uygulamasında, birinci biyolojik arıtma adımında biyolojik olarak ayrışabilir organik maddeler giderilmiş; ara ozonlama prosesi olarak uygulanan kimyasal arıtma fazında ise ? ikinci biyolojik arıtma adımı için ? kalıntı organik maddelerin biyolojik ayrışabilirliği iyileştirilmiştir. Son ozonlama prosesinde ? ozonlama işleminin daha konsantre çözünmüş inert KOİ bileşeni içeren atıksu üzerinde uygulanması gerekçesiyle ön / ara / son ozonlama prosesleri içerisinde ? en yüksek toplam inert KOİ giderimi / kullanılan ozon oranlarına erişilmiştir. Ara ve son ozonlama proseslerinin hangisinin en uygun çözüm olduğunun belirlenmesi aşamasında, aralarında teknik ve ekonomik etmenlerin de yer aldığı çok sayıda faktör göz önünde bulundurulmalıdır. Çalışmanın ikinci ayağında ise, literatürde tanımlanan değerlere oranla çok daha düşük spesifik ozon dozları (4~11 mg O3/g AKM) uygulanarak ozonlama işleminin ve ozon besleme süresinin çamurun dezentegrasyonu, katı madde türleri, bileşenleri, çökelebilirliği, filtre edilebilirliği, solubilizasyon karakteristikleri ve biyolojik olarak ayrışabilirliği üzerindeki etkileri incelenmiştir. Aerobik biyodegradasyon deneylerinde, ozonlama işleminin biyolojik degradasyon ile rekabet edici şekilde çalışmadığı ve organik maddenin dekompozisyonu sırasında birinci adımda gözlemlenen solubilizasyon mekanizmasının baskın tutularak atık aktif çamurun biyolojik ayrışabilirliğinin iyileştirildiği; dolayısıyla da kısmi oksidasyona dayalı ozonlama işleminin ardışık biyolojik degradasyon adımı için bir ön-oksidasyon basamağı olarak işletilebileceği saptanmıştır.
Özet (Çeviri)
In the first part of this study, the optimal location of ozonation within biological treatment for tannery wastewater samples is evaluated. Pre-ozonation, undesirably competing with biotreatment for the removal of degradable organics, is only effective on biodegradable part of the COD; leaving all the inert COD as it is. In a combined treatment scheme of biological treatment + ozonation + biological treatment, easily biodegradable COD can be removed by the first biological treatment; then the following ozonation serves as an in-mid process to ease the further biological treatment by either chemically converting the inert COD to biodegradable forms and / or increasing the rates of biodegradation of organics. Among all the runs, the application of post-ozonation gives the highest inert COD removal / utilized ozone ratios; since the ozone is applied to the outlet of biological treatment that mainly contains recalcitrant COD fractions. The choice between in-mid ozonation or post-ozonation alternatives should be carried out considering technical and economical factors. In the second part of this study, the effects of both ozonation and ozone feeding time on disintegration properties, solid matter species, components, settleability and filterability features, solubilization characteristics and biodegradability properties of the sludge are investigated via employing low specific ozone doses ranging from 4 to 11 mg O3/g SS. The partial oxidation by integrated ozonation is operated as a pre-oxidation step for the subsequent biological degradation, as the organic matter decomposition is dominated by solubilization due to disintegration of suspended solids and a more biodegradable sludge composition is obtained by means of ozonation.
Benzer Tezler
- Modelling the fate of particular components in aerobic sludge stabilization for alkaloid wastewater using membrane bioreactor
Alkaloid atık suyunun membran biyoreaktör ile arıtılmasıyla oluşan atık çamurun aerobik çamur stabilizasyonunda partiküler bileşenlerin modellenmesi
GİZEM YÜKSEL EKER
Yüksek Lisans
İngilizce
2015
Çevre Mühendisliğiİstanbul Teknik ÜniversitesiÇevre Mühendisliği Ana Bilim Dalı
PROF. DR. EMİNE ÇOKGÖR
- Boya atık sularının arıtılabilirliği
The Treatability of paint industry wastewaters
SERDAR GÖKŞEN
Yüksek Lisans
Türkçe
2003
Çevre Mühendisliğiİstanbul Teknik ÜniversitesiÇevre Mühendisliği Ana Bilim Dalı
PROF. DR. FATOŞ GERMİRLİ BABUNA
- Investigation of cod behavior by modelling of activated sludge system with a membrane module (MASM)
Modifiye edilmiş KOI davranışlarının membran modülü kullanılan aktif çamur sistemlerinde incelenmesi
AYŞE BEGÜM YÜCEL
Yüksek Lisans
İngilizce
2020
Çevre Mühendisliğiİstanbul Teknik ÜniversitesiÇevre Mühendisliği Ana Bilim Dalı
PROF. DR. SEVAL SÖZEN
- Treatment of municipal wastewater and organic waste by a pilot scale high rate activated sludge system
Evsel atık su ve organik atıkların pilot ölçekli yüksek hızlı aktif çamur prosesi ile arıtımı
DİLARA SANCAR
Yüksek Lisans
İngilizce
2017
Çevre Mühendisliğiİstanbul Teknik ÜniversitesiÇevre Mühendisliği Ana Bilim Dalı
PROF. DR. İZZET ÖZTÜRK
- Biogas recovery during anaerobic treatment of lignocellulose-rich pollutants with high sulphate content: an investigation via innovative applications
Yüksek sülfat içerikli lignoselüloz bakımından zengin kirleticilerin havasız arıtımı sırasında biyogaz geri kazanımı: yenilikçi uygulamalarla bir araştırma
EDA YARSUR
Yüksek Lisans
İngilizce
2021
Çevre Mühendisliğiİstanbul Teknik ÜniversitesiÇevre Mühendisliği Ana Bilim Dalı
PROF. DR. ÇİĞDEM GÖMEÇ