Sıcaklık ve nem faktörlerinin anestezik gazlar üzerindeki etkileri

The effects of temperature and humidity on the anesthetic gases

  1. Tez No: 252716
  2. Yazar: FATİH MEHMET DOĞRUYOL
  3. Danışmanlar: PROF. DR. AYDIN AKAN
  4. Tez Türü: Yüksek Lisans
  5. Konular: Anestezi ve Reanimasyon, Biyomühendislik, Anesthesiology and Reanimation, Bioengineering
  6. Anahtar Kelimeler: Anestezi ve analjezi, Anestezi-genel, Anestezi-inhalasyon, Anestezi-kapalı devre, Anesthesia and analgesia, Anesthesia-general, Anesthesia-inhalation, Anesthesia-closed circuit
  7. Yıl: 2009
  8. Dil: Türkçe
  9. Üniversite: İstanbul Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Biyomedikal Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Sağlık sektöründeki kalite çalışmaları kapsamında, medikal cihazların uluslararası standartlara uygun olup olmadığının tespiti ve dolayısıyla kalibrasyon ölçümleri çok büyük önem arz etmektedir. Bu tezin amacı; sıcaklık ve nem faktörünün vaporizatörden verilen gaz miktarına etkisinin araştırılması ve operasyon sırasında hastaya verilecek gaz miktarının ayarlanmasında bu faktörlerin göz önünde bulundurulmasını sağlamaktır.Tezin ilk bölümünde anestezinin tanımı verilmiş ve anestezi türleri ele alınmıştır. Anestezinin tarihsel gelişimi incelenerek anestezik ajanların kullanım alanlarına göre sınıflandırılması yapılmıştır. Klinik uygulamalarda rutin tekniklerden birisi haline gelen düşük akımlı anestezinin pozitif ve negatif yönleri tartışılmıştır. Düşük akımlı anestezinin riskleri değerlendirilerek bu risklerin azaltılmasına yönelik teknik değerlendirmeler ele alınmıştır.Buharlaşmaya hazır haldeki özellikle formüle edilmiş uçucu ajanlar organik sıvılardır ve genel anestezinin başlaması ve sürdürülmesi için solunum yoluyla verilirler. Düşük akımlı anestezi uygulamalarında izofluran ve sevofluran en yaygın kullanılan ajanlardır. İzofluran ve sevofluran gazlarının özellikleri ele alınmış ve teknik açıdan karşılaştırmaları yapılmıştır. Tezin ilk bölümünün son kısmında anestezik gaz yoğunlaşmasında sıcaklık ve basıncın etkisi araştırılarak farklı sıcaklık ve basınç değerleri altında anestezik ajanların etki düzeyindeki değişim ortaya konulmuştur.Tezin ikinci ve üçüncü bölümlerinde anestezi uygulamalarında kullanılan cihazların kullanım alanları ve kullanım teknikleri ele alınmıştır. Bu çalışmada anestezi cihazının performansı değerlendirilmiş ve cihazın hastaya ayarlanan değeri verip vermediği ölçülmüştür. Daha sonra anestezi cihazının sıcaklık ve nem değerleri değiştirilerek, bu faktörlerin etkisinde nasıl bir değişime uğradığı incelenmiştir. Yapılan çalışmada izofluran ve sevofluran gazlarının sıcaklık-nem faktörüne göre etkilerinin değişimi ölçülmüştür. Elde edilen veriler istatistik hesaplama yapılarak değerlendirilmiş ve sıcaklık ve nem faktörlerinin anestezik gaz miktarında yarattığı değişikliğin analizi yapılmıştır.

Özet (Çeviri)

Within the framework of quality management endeavors in medical services, calibration gained great importance through appropriacy of medical devices. The aim (goal, objective)of this study is to investigate the effects of temperature and humidity factors to the amount of gas output from the vaporizer and to enhance the consideration of these factors while adjusting he amount of gas to be given to the patient during (through) the operation (surgery).The definition and types of anesthesia are studied in the first section of the thesis. Historical development of anesthesia is studied with classification of anesthetic agents according to their field of use. Advantages and disadvantages of Low Flow Anesthesia, which became a routine technique in clinical applications, are discussed. The risks of Low Flow Anesthesia and technical precautions in order to reduce the rate of these risks are considered.Volatile agents ready to evaporate, especially formulated volatile agents, are organic liquids and they are applied to the patient through the respiratory system during induction and maintenance of general anesthesia. Isoflurane and sevoflurane are the most commonly used agents in Low Flow Anesthesia applications. The properties of isoflurane and sevoflurane gases are studied with their technical comparisons. In the final part of the first section of this study the effects of temperature and pressure to the anesthetic gas concentration and the rate of change in anesthetic depth under different values of temperature and pressure are introduced.In the second and third sections of the thesis, the application areas and application techniques of machines (devices) used in anesthesia are introduced. In this study, the performance of the anesthesia machine is evaluated with whether it supplied the dialed amount of anesthetic to the patient. Then, through changing the temperature and humidity values (rates) of anesthetic device, the results of changes in these factors are observed. The changes in the effects of isoflurane and sevoflurane gases according to the temperature-humidity factors are measured. The data gathered are evaluated with statistical study and therefore the effect of temperature and humidity in the amount of anesthetic gas is analyzed.

Benzer Tezler

  1. Yanık yaralarının tedavisinde değişik epidermal büyüme faktörü (EGF) formülasyonlarının etkisinin incelenmesi

    Investigation of the effects of different epidermal growth factor (EGF) formulations on the treatment of burn wounds

    NAZLI CEREN İŞBAŞAR

    Yüksek Lisans

    Türkçe

    Türkçe

    2003

    Eczacılık ve FarmakolojiGazi Üniversitesi

    Farmasötik Teknoloji Ana Bilim Dalı

    Y.DOÇ.DR. ZELİHAGÜL DEĞİM

  2. Karaciğer canlı donörlerinde istenmeyen perioperatif hipotermi insidansı ve etkileyen etmenlerin incelenmesi

    Incidence of inadvertent perioperative hypothermia in liver living donors and investigation of affecting factors

    SULTAN AYDINAY

    Yüksek Lisans

    Türkçe

    Türkçe

    2023

    HemşirelikEge Üniversitesi

    Hemşirelik Esasları Ana Bilim Dalı

    PROF. DR. LEYLA KHORSHTD

  3. V-kayış kasnak mekanizmalarında çevresel faktörlerden ısı ve nem faktörlerinin kaymaya etkisinin deneysel incelenmesi

    Experimental analysis of temperature and relative hummadity out of external parameters affecting the construction of V-belt pulley mechanism

    ABDULKADİR CENGİZ

    Yüksek Lisans

    Türkçe

    Türkçe

    2002

    Makine MühendisliğiKocaeli Üniversitesi

    Makine Eğitimi Ana Bilim Dalı

    YRD. DOÇ. DR. MEHMET UÇAR

  4. Hurma zeytininin pomolojik özellikleri ve hurmalaşmaya etki eden faktörler üzerinde araştırmalar

    Başlık çevirisi yok

    HASAN HAKAN PAMUK

    Yüksek Lisans

    Türkçe

    Türkçe

    1993

    ZiraatEge Üniversitesi

    Bahçe Bitkileri Ana Bilim Dalı

    PROF. DR. KADİR MENDİKİOĞLU

  5. Simmental ve esmer sığır ırklarında sıcaklık stresinin bazı üreme ve süt verimi özellikleri üzerindeki etkileri

    The effect of heat stress on some reproductive and milk production traits in simmental and brown swiss cattle breeds

    ADİL AKIN AYDIN

    Doktora

    Türkçe

    Türkçe

    2024

    ZiraatAnkara Üniversitesi

    Zootekni Ana Bilim Dalı

    PROF. DR. GÜRSEL DELLAL