Geri Dön

Eser miktarda nikel tayini için yeni katı faz ekstraksiyon metodu

New solid phase extraction method for determination of trace nickel

  1. Tez No: 259172
  2. Yazar: HALİL YALÇIN
  3. Danışmanlar: PROF. DR. ALİ ÖLÇÜCÜ, YRD. DOÇ. DR. HARUN ÇİFTÇİ
  4. Tez Türü: Yüksek Lisans
  5. Konular: Kimya, Chemistry
  6. Anahtar Kelimeler: Katı faz ekstraksiyonu, Amberlite XAD?7, BPMBAD, Nikel, Zenginleştirme, FAAS, Solid phase extraction, Amberlite XAD?7, BPMBAD, Nickel, Preconcentration, FAAS
  7. Yıl: 2010
  8. Dil: Türkçe
  9. Üniversite: Fırat Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Kimya Ana Bilim Dalı
  12. Bilim Dalı: Analitik Kimya Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Ağır metal olan nikel birçok canlı organizma için toksik özelliklere sahiptir. Bu yüzden çevre örneklerinde eser düzeyde bulanan nikelin tayin edilebilmesi büyük önem taşımaktadır. Bu çalışmada, eser düzeydeki nikelin tayin edilebilmesi için yeni, hassas basit ve geçerli katı faz ekstraksiyon metodu geliştirilmiştir. Bu araştırmada, nikel iyonları, Amberlit XAD?7 içeren kolonda, N,N-Bis(Piridin-2-il-metilen)Benzen-1,4-Diamin (BPMBAD) ligandı ile şelat oluşturularak (Ni- PPANP) zenginleştirilmiş ve Alevli Atomik Absorpsiyon Spektrometresi (FAAS) ile tayin edilmiştir. Çalışmalarda, ortamın pH'ı, numune ve eluent akış hızı, reçine miktarı, ligand miktarı gibi deneysel parametreler optimize edilmiştir. Yöntemin geçerliliği üzerine ortam iyonlarının etkisi ayrıca belirlenmiştir. Ni-BPMBAD şelatlarının kantitatif sorpsiyonu için en uygun pH değerleri 6?8 arası bulunmuştur. Eluasyon işlemleri 6 mL, 2 mol L-1 HCl çözeltisi kullanarak yapılmıştır. Optimize edilen şartlarda 750 mL su örnekleri için zenginleştirme faktörü 125 olarak bulunmuştur. Yöntemin standart sapma ve gözlenebilme sınırı sırasıyla %2,8 ve 0.44 ?g L-1 olarak bulunmuştur. Geliştirilen yöntem bazı içme ve mineral sularında eser düzeydeki nikelin tayini için başarılı bir şekilde uygulanmış ve uygun geri kazanım sağlanmıştır. (100,0?103,5%).

Özet (Çeviri)

Nickel, as a heavy metal, is toxic for many living species. Thus, the determination of trace amounts of nickel in environmental samples is of great importance. In this study, a new, sensitive, simple and validated solid-phase extraction method is developed for the determination of nickel in level. In this research, nickel ions were preconcentrated as N,N-Bis(Piridin-2-il-metilen)Benzen-1,4-Diamin (BPMBAD) chelates (Ni-BPMBAD) from sample solutions using a column containing Amberlite XAD-7 and determined by flame atomic absorption spectrometry (FAAS). The optimum experimental parameters such as pH of the medium, sample flow rate, eluent and effect of matrix ions on the method efficiency were investigated. The optimum pH value for quantitative sorption of Ni-BPMBAD was found between 6.0 and 8.0. Elution process was performed by using 6 mL of 2 mol L-1 HCl. The preconcentration factor was found as 125, in optimized conditions. The relative standard deviation and detection limit were found to be 2.8% and 0.44 ?g L-1, respectively. The method was successfully applied to determine the trace amounts of nickel in tap water and mineral waters, and suitable recoveries were obtained (100.0?103.5%).

Benzer Tezler

  1. İletken polymerler kullanılarak nötral ve iyonik türlerin analizi için elektrokimyasal kontrollü katı faz mikroekstraksiyonu

    Electrochemical control of solid phase microextraction using conducting polymers for the analysis of neutral and ionic species

    UĞUR TAMER

    Doktora

    Türkçe

    Türkçe

    2003

    KimyaHacettepe Üniversitesi

    Kimya Ana Bilim Dalı

    PROF. DR. KADİR PEKMEZ

  2. Termomineral sularda ve meyve sularında kurşun, bakır ve nikel tayini için analitik yöntem geliştirilmesi

    Development of analytical method for determination of lead, copper and nickel in thermomineral waters and fruit juices

    HİLAL YILDIZ KARAKOÇ

    Yüksek Lisans

    Türkçe

    Türkçe

    2019

    Beslenme ve DiyetetikKırşehir Ahi Evran Üniversitesi

    Moleküler Tıp Ana Bilim Dalı

    PROF. DR. HARUN ÇİFTÇİ

    DR. ÖĞR. ÜYESİ ÇİĞDEM ER ÇALIŞKAN

  3. Seçilen ekstraktif çözgenin etilasetat-etilalkol azeotropik sistemi üzerine etkisi

    Başlık çevirisi yok

    NAŞİDE FİDİ

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    Kimya MühendisliğiEge Üniversitesi

    Kimya Mühendisliği Ana Bilim Dalı

    DOÇ. DR. ERDEN ALPAY

  4. Yahya Kemal'de bedii tefekkür unsurları: 1 Kendi Gök Kubbemiz'de duygu

    Başlık çevirisi yok

    MUSTAFA ÖZBALCI

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Türk Dili ve EdebiyatıGazi Üniversitesi

    Türk Dili ve Edebiyatı Ana Bilim Dalı

    DOÇ. DR. SADIK K. TURAL