Geri Dön

Elektron ışın dozimetrisinde Monte Carlo simülasyon yöntemi kullanılarak elde edilen doz dağılımlarının gerçek dozimetri sonuçları ile karşılaştırılması

Comparision of electron beam dosimetry dose distributions obtained using Monte Carlo simulation methods with actual dosimetry

  1. Tez No: 281947
  2. Yazar: SEZEN KOÇOĞLU
  3. Danışmanlar: PROF. DR. FADİME AKMAN, ÖĞR. GÖR. ZAFER KARAGÜLER
  4. Tez Türü: Yüksek Lisans
  5. Konular: Onkoloji, Oncology
  6. Anahtar Kelimeler: Elektron ışın dozimetrisi, Monte Carlo Simülasyonu, Voxel Monte Carlo (VMC++), Benzetim, Doz-cevap ilişkisi-radyasyon, Monte Carlo benzetimi, Radyasyon, Radyasyon dozajı, Radyometri, Electron beam dosimetry, Monte Carlo Simulation, Voxel Monte Carlo (VMC++), Simulation, Dose-response relationship-radiation, Radiation, Radiation dosage, Radiometry
  7. Yıl: 2011
  8. Dil: Türkçe
  9. Üniversite: Dokuz Eylül Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Medikal Fizik Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmada amaç, elektronlar için Voxel Monte Carlo (VMC++) algoritması kullanarak hesap yapabilen Oncentra® Tedavi Planlama bilgisayarında 12 ve 18 MeV elektron enerjilerinde ve farklı boyutlardaki alanlarda, referans koşullarda yapılan hesaplamalar ile elde edilen sonuçları gerçek dozimetri sonuçları ile karşılaştırmaktır.Çalışmada, standart 15x15 cm2 elektron aplikatörüne göre hazırlanan 12x12 cm2, 12x10 cm2, 12x8 cm2, 12x6 cm2, 10x10 cm2 ve R=10 cm'lik alanlar kullanılmıştır. Bu alanlar Nucletron marka Oncentra® MasterPlan tedavi planlama sisteminde (TPS) tanımlanarak referans koşullar oluşturulmuş ve VMC++ algoritması ile hesap yaptırılmıştır. TPS'de hesaplatılan dozlar cm2 başına 50.000 ve 100.000 elektron öykü sayısına göre belirlenmiştir. Çalışmanın ikinci aşamasında aynı alanlar ve referans koşullarında gerçek dozimetri yapılarak elde edilen sonuçlar TPS sonuçları ile karşılaştırılmıştır. Bu karşılaştırmada ± %2'ye varan farklar elde edilmiştir. Bu farklar 12 MeV elektron enerjisi için en yüksek -%2,30, en düşük %0,13 ve 18 MeV için en yüksek %1,36, en düşük -%0,07 olarak bulunmuştur.Elde edilen sonuçların, literatürle uyumlu ve ±%3 klinik kabul sınırları içerisinde olduğu bulunmuştur. Büyük farklılıkların daha çok küçük alanlarda olduğu görülmüştür.

Özet (Çeviri)

Aim of this study is comparing calculated dosimetric results from using Voxel Monte Carlo (VMC++) algorithm in Oncentra® treatment planning for 12 and 18 MeV electron energies and different fields under reference conditions, with actual dosimetry results.In the study, 12x12 cm2, 12x10 cm2, 12x8 cm2, 12x6 cm2, 10x10 cm2 and R=10 cm fields in accordance with standard 15x15 cm2 electron applicator were used. The reference conditions were defined for these fields in Oncentra® MasterPlan (brand of Nucletron) treatment planning system (TPS) and performed calculations with VMC++ algorithm. The calculated doses in the TPS were determined as 50.000 and 100.000 number of electrons history per cm2. In the second phase of the study, performed actual dosimetry results were compared with dosimetric results from TPS under reference conditions of the same fields. The differences of up to ±2% was obtained in this comparison. The highest and lowest levels of these differences were -2,30% and 0,13% for 12 MeV electron energy; 1,36% and -0,07% for 18 MeV electron energy; respectively.Our results in this study were found within the limits of ± 3% of clinical acceptance and accordance with literature. Big differences were observed in very small fields.

Benzer Tezler

  1. Fantom malzemelerinin doku denkliğinin deneysel ve teorik olarak incelenmesi

    Experimental and theoretical investigation of tissue equivalency for phantom materials

    İREM ERK

    Yüksek Lisans

    Türkçe

    Türkçe

    2016

    Radyoloji ve Nükleer Tıpİstanbul Teknik Üniversitesi

    Nükleer Araştırmalar Ana Bilim Dalı

    PROF. DR. NESRİN ALTINSOY

  2. Akciğer kanserinin cyberknife ile stereotaktik radyoterapisinde ray-trace ve monte carlo hesaplama algoritmalarıyla elde edilen doz dağılımlarının karşılaştırılması

    Comparison of dose distributions to obtained by ray-trace and monte carlo calculation algorithms for with cyberknife stereotactic radiotherapy of lung cancer

    İSMAİL FARUK DURMUŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    2013

    Fizik ve Fizik Mühendisliğiİstanbul Üniversitesi

    Onkoloji Ana Bilim Dalı

    PROF. DR. GÖNÜL KEMİKLER

  3. Plazma arkı eldesi ve yüzey bölgesi modifikasyonunda kullanılabilirliği

    Başlık çevirisi yok

    ÖZKAN ÖZİPEKLİLER

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Makine MühendisliğiUludağ Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    DOÇ. DR. HALİM DEMİRCİ

  4. Kurbağa gastrik mukozasında K-H ATPaz enziminin kinetik özellikleri ve oluşturulan ülser modelinde enzim aktivitesi

    Başlık çevirisi yok

    SEYHAN TÜKEL

    Doktora

    Türkçe

    Türkçe

    1987

    BiyokimyaÇukurova Üniversitesi

    Biyokimya Ana Bilim Dalı

    DOÇ. DR. TURGAY İSBİR

  5. Pik demiri ve karbon çeliğinin sulu çözeltiler içindeki korozyon hızının tayini

    Determination of the rate of corrosion of the cast iran and carbon steel in the aqueous solutions

    EMİNE NAZAN ÜNAL

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Kimya MühendisliğiGazi Üniversitesi

    Kimya Mühendisliği Ana Bilim Dalı

    DOÇ. DR. HAYRİ YALÇIN