Geri Dön

İntravenöz uygulamalarda üç yollu musluk ile iğnesiz enjeksiyon valfi kullanımının enfeksiyon gelişimine etkisinin karşılaştırılması

Comparing the effects of three-way stopcock usage and needle-free injection valve usage on infection development in intravenous practices

  1. Tez No: 293595
  2. Yazar: IŞIL KÜÇÜKER
  3. Danışmanlar: YRD. DOÇ. DR. BİLGİ GÜLSEVEN KARABACAK
  4. Tez Türü: Yüksek Lisans
  5. Konular: Hemşirelik, Nursing
  6. Anahtar Kelimeler: Üç yollu musluk, iğnesiz enjeksiyon valfi, kateter ilişkili enfeksiyon, three-way stopcock, needle-free injection valve, catheter related infection
  7. Yıl: 2011
  8. Dil: Türkçe
  9. Üniversite: Marmara Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Hemşirelik Esasları Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 90

Özet

Araştırma; intravenöz uygulamalarda üç yollu musluk ile iğnesiz enjeksiyon valfi kullanımının enfeksiyon gelişimine etkisinin karşılaştırılması amacıyla tanımlayıcı ve randomize kontrollü olarak planlandı ve gerçekleştirildi. Araştırmanın evrenini Eylül 2010- Şubat 2011 tarihleri arasında özel bir hastanede Genel Servis 1-2-3-4'te yatarak tedavi gören ve periferik intravenöz kateter takılan hastalar oluşturdu. Örneklem grubunu ise bu hastalar arasından intravenöz uygulamalarda iğnesiz enjeksiyon valfi kullanılan 30 hasta (deney); üç yollu musluk kullanılan 30 hasta (kontrol) olmak üzere toplam 60 hasta oluşturdu. Deney ve kontrol grubundaki hastaların periferik venöz kateterleri takıldıktan 72 saat sonra çıkartılarak kateter ucu kültürü alındı. Araştırma verilerinin toplanmasında `Hasta Tanılama Formu' ve kültür sonuçlarından yararlanıldı. Veri analizinde istatistiksel analizler için SPSS (Statistical Package for Social Sciences) for Windows 17.0 programı kullanıldı. Çalışma verileri değerlendirilirken tanımlayıcı istatistiksel yöntemler (Frekans, Yüzde, Ortalama, Standart sapma) kullanıldı. Verilerin karşılaştırılmasında ise Pearson Ki-Kare ( ve t testleri kullanıldı. Araştırmanın sonucunda, iğnesiz enjeksiyon valfi ve üç yollu musluk kullanılan hastalar arasında yaş, cinsiyet, kronik hastalık durumu, kronik hastalığın çeşidi ve yatış süresi açısından anlamlı fark bulunmadı. Üç yollu musluk kullanılan hastalarda üreme görülme oranı %6.7 (n=2) iken; iğnesiz enjeksiyon valfi kullanılan hastalarda üreme görülmedi.Sonuç olarak, asepsi ilkelerine uymak koşuluyla iğnesiz enjeksiyon valflerinin enfeksiyon açısından güvenilir araçlar olduğu sonucuna varıldı.

Özet (Çeviri)

The research has been planned and realized as descriptive and randomized controlled for the purpose of comparing the effects of three-way stopcock usage and needle-free injection valve usage on infection development. The universe of the research consisted of the inpatients that were treated in a private hospital?s General Service 1-2-3-4 between September 2010 and February 2011 and had peripheral intravenous catheters. The sample group consisted of 30 patients on whom needle-free injection valve was used for intravenous practices (experiment group) and 30 patients on whom three way stopcock was used (control group), in total 60 patients among all the patients that formed the research universe. 72 hours after the peripheral venous catheters of the patients in the experiment and control groups were placed, they were taken out and culture from tip of the catheter was obtained. ?Patient Diagnosis Form? and culture results were utilized in collecting research data. SPSS (Statistical Package for Social Sciences) for Windows 17.0 program was used for statistical analyses in data analysis. Descriptive statistical methods (Frequency, Percentage, Average, Standard deviation) were used in evaluating the research data. Pearson Chi-Square ( and t tests were used in comparison of the data. As the result of the research, no significant difference was found between patients on whom needle-free injection valve was used and patients on whom three-way stopcock was used in terms of age, gender, chronic disease, chronic disease type and the length of stay in the hospital. Among the patients on whom three-way stopcock was used the reproduction percentage was 6.7% (n=2) whereas there was no reproduction among patients on whom needle-free injection valve was used.As a result, it was concluded that, providing that asepsis principles are followed, needle-free injection valves are reliable tools in terms of infection.

Benzer Tezler

  1. Üç yollu musluk ve split septumlu enjeksiyon valfi kullanımının periferik venöz kateter enfeksiyonu ve kolonizasyonuna etkileri

    The effects of three-way stopcock and split septum injection valve usage on catheter infection and colonization

    HİLAL TÜRKBEN POLAT

    Doktora

    Türkçe

    Türkçe

    2016

    Hemşirelikİnönü Üniversitesi

    Hemşirelik Ana Bilim Dalı

    PROF. DR. BEHİCE ERCİ

  2. Geriatrik hastalarda subkutan infüzyonla yapılan hidrasyonun etkinliğinin incelenmesi

    Study on examining the efficacy of subcutaneous hydration administration in geriatric patients

    GAYE ÖZ ESMERAY

    Doktora

    Türkçe

    Türkçe

    2017

    GeriatriHaliç Üniversitesi

    Hemşirelik Ana Bilim Dalı

    DOÇ. DR. LEMAN ŞENTURAN

    DOÇ. DR. ALPER DÖVENTAŞ

  3. Subtoksik dozlarda uygulanan İvermektin ve Karprofen'in farmakokinetiği / toksikokinetiği üzerine damar içi yağ emülsiyonunun etkilerinin araştırılması

    Investigation of the effects of intravenous lipid emulsion on the pharmacokinetics / toxicokinetics of Ivermectin and Carprofen administered at subtoxic doses

    BÜŞRA ASLAN AKYOL

    Doktora

    Türkçe

    Türkçe

    2023

    Veteriner HekimliğiBalıkesir Üniversitesi

    Farmakoloji ve Toksikoloji (Veterinerlik) Ana Bilim Dalı

    PROF. DR. CENGİZ GÖKBULUT

  4. Kafa travmalarında kraniyal bilgisayarlı beyin tomografisinde mezensefalon çevresi sisternaların büyüklüğüne göre mannitol tedavisinde farklı doz uygulamaları

    The treatment of head traumas with different mannitol doses according to the size of perimesencephalic cisterns in computed tomography

    YÜCEL DÜZENLİ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2009

    NöroşirürjiDicle Üniversitesi

    Beyin ve Sinir Cerrahisi Ana Bilim Dalı

    PROF. DR. ADNAN CEVİZ

  5. Development and functionalization of novel polymeric materials from poly(oxazoline)s for potential bioapplications

    Potansiyel biyouygulamalar için poli(oksazolin)lerden yeni polimerik materyallerin geliştirilmesi ve fonksiyonlandırılması

    UMUT UĞUR ÖZKÖSE

    Doktora

    İngilizce

    İngilizce

    2020

    Kimyaİstanbul Teknik Üniversitesi

    Kimya Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ ONUR ALPTÜRK

    DR. ÖZGÜR YILMAZ