6 ve 18 MV enerjili fotonların sudaki derin dozlarının penelope MC programı ile hesabı ve ölçümü

Depth dose of 6 and 18 MV photons in water measurement and calculation by the penelope MC code

  1. Tez No: 324810
  2. Yazar: BURCU KARAYUNUS
  3. Danışmanlar: PROF. DR. NAZMİ TURAN OKUMUŞOĞLU
  4. Tez Türü: Yüksek Lisans
  5. Konular: Fizik ve Fizik Mühendisliği, Physics and Physics Engineering
  6. Anahtar Kelimeler: Su için 6 ve 18 MV foton yüzde derin doz değerleri, PENELOPE Monte Carlo Simülasyonu, derin doz, Derin doz Fonksiyonu, 6 and 18 MV photon water percent depth dose values, PENELOPE Monte Carlo Simulation, depth dose, depth dose function
  7. Yıl: 2013
  8. Dil: Türkçe
  9. Üniversite: Recep Tayyip Erdoğan Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Fizik Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 144

Özet

Bu çalışmada 6 ve 18 MV enerjilerde yayınlanan fotonların su ile etkileşiminde en güncel fizik modellerini kullanan PENELOPE Monte Carlo kodu 2011 kullanılmış; derin doz ve enerji dağılımı, açısal dağılım, etkileşme tesir kesitleri, kütle soğurma katsayıları, ortalama serbest yol, menzil, durdurma gücü değerleri gibi birçok fiziksel parametre hesaplanmıştır. PENELOPE derin doz değerlerinden, deneysel yüzde derin doz değerleri (YDD) ile karşılaştırmak üzere YDD değerleri elde edilmiştir. Çalışmada ayrıca yüzde derin doz değerleri Ondokuz Mayıs Üniversitesi (OMÜ) Tıp Fakültesi Uygulama ve Araştırma Hastanesi Radyasyon Onkolojisi Anabilim Dalında bulunan Varian marka Clinac DHX lineer hızlandırıcısından deneysel olarak elde edilmiştir. Bu amaçla Ondokuz Mayıs Üniversitesi (OMÜ) Tıp Fakültesi Uygulama ve Araştırma Hastanesi Radyasyon Onkolojisi Anabilim Dalında çalışılmıştır.Deneysel çalışmada, 6 ve 18 MV enerjilerde yayınlanan fotonların hızlandırcı kafasından 100 cm aşağıya yerleştirilen su fantomu ile etkileşmeleri incelenmiş, YDD değerleri, derinliğin (z) fonksiyonu olarak ölçülmüş, bu değerlerin ortalama ve standart sapmaları hesaplanmış sonuçların bir standart sapma içinde sabit olduğu saptanmıştır. Deneysel sonuçların BJR 25 (The British Journal of Radiology (1996)) değerleri ile uyumlu olduğu görülmüştür.Tezde 6 ve 18 MV enerjili fotonların deneysel sonuçları için en uyumlu fit eğrileri elde edilmiştir. Elde edilen MC hesap sonuçları ile deneysel sonuçlar arasında, deneysel sistemin geometrisindeki farklılıklardan kaynaklanan, farklar bulunmuştur. Hızlandırıcı kafasından gelen ve su fantomundan kaynaklanan Bremsstrahlung katkıları eklendiğinden farkların ortadan kaybolduğu dolayısı ile MC hesaplarının sistem geometrisi tanımlandığında deneyselle çok iyi uyuşan sonuçlar vereceği açıkça görülmüştür.

Özet (Çeviri)

In this study, we used PENELOPE Monte Carlo Code version 2011 which uses most update physical models for the interaction of 6 and 18 MV photons with water and calculated the depth dose, percent depth dose values and physical parameters such as energy distribution, angular distribution, interaction cross-sections, mass absorption coefficients, mean free path and range, stopping power. .YDD (percentage depth dose) values were obtained from PENELOPE depth dose values to compare with the experimental values of percentage depth dose(YDD). In the study, also, percentage depth dose values obtained experimentallyI For this, Varian Clinac DHX linear accelarator of Ondokuz Mayıs University, Faculty of Medicine, Depatment of Radiation Oncology was used.In the experimental work interactions of 6 and 18 MV photons with water phantom placed 100 cm from the accelerator head were examined and PDD values were measured as a function of depth (z). and avarage PDD values together with standart deviations (SD) were calculated. The results are in agreement with in one. The experimental results are also in good agreement with that of BJR 25 (The British Journal of Radiology (1996)):Best fit curves for 6 and 18 MV experimental results were obtained. The differences are found in the results because of the differences in the geometry of the experimental system. The differences mostly dissappered when we included the bremsstrahlung contribution coming from the head and water phantom.

Benzer Tezler

  1. Radyoterapide kullanılan lineer hızlandırıcıda elektron sanal kaynak mesafelerinin ve foton kaynak mesafelerinin tespiti

    In the unit used in radiotherapy of linear accelerator, the electron virtual source distance and photons range for sources determination

    FATİH ÇAĞLAR KAHRAMAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2010

    Fizik ve Fizik MühendisliğiGazi Üniversitesi

    Fizik Ana Bilim Dalı

    DOÇ. DR. EYYUP TEL

  2. Bazı element ve bileşiklerde 6 MV ve 18 MV Bremsstrahlung radyasyonu için ve bazı su fantomlarında tek enerjili X-ışınları için foton etkileşim parametrelerinin incelenmesi

    Investigation of photon interaction parameters in some elements and compounds for Bremsstrahlung radiation of 6 MV and 18 MV and for monoenergetic X-ray beams in some water phantoms

    ALPDOĞAN ÇELİK

    Yüksek Lisans

    Türkçe

    Türkçe

    2012

    Fizik ve Fizik MühendisliğiAtatürk Üniversitesi

    Fizik Ana Bilim Dalı

    YRD. DOÇ. DR. MURAT KURUDİREK

  3. Kanserli dokulardaki bazı iz element derişimlerinin radyoterapide alınan doz üzerindeki etkisinin deneysel olarak ölçülmesi ve gate/GEANT4 programı ile modellenerek incelenmesi

    Experimental measurement of the effect on the radiation dose in radiotherapy of some trace element concentrations in cancerous tissues and modelling using gate/GEANT4 simulation code

    TURAN ŞAHMARAN

    Doktora

    Türkçe

    Türkçe

    2021

    Fizik ve Fizik MühendisliğiAnkara Üniversitesi

    Fizik Ana Bilim Dalı

    PROF. DR. AYŞE KAŞKAŞ

  4. Yüksek enerjili x-ışınları üreten lineer hızlandırıcı (Linak) ünitesinde radyasyon doz ölçümleri

    The radiation dose measurements on linear accelarator (Linac) unit, produces high energy x-rays

    AYSUN İNAL

    Doktora

    Türkçe

    Türkçe

    2011

    Fizik ve Fizik MühendisliğiSüleyman Demirel Üniversitesi

    Fizik Ana Bilim Dalı

    PROF. DR. İSKENDER AKKURT

  5. Sıvıların radyasyon dozuna duyarlılıkları

    Susceptibility of liquids to radiation dose

    DUYGU ECE ÇELİK

    Yüksek Lisans

    Türkçe

    Türkçe

    2014

    Radyoloji ve Nükleer TıpGaziosmanpaşa Üniversitesi

    Fizik Ana Bilim Dalı

    DOÇ. DR. İBRAHİM YİĞİTOĞLU