15-kanallı transmıt-receive diz sargısı ve 3 tesla MR cihazı ile elde olunan MR görüntülerinin diz patolojilerini göstermedeki etkinliği
The diagnostic performance of 3T MR images obtained with 15 channel transmit-receive knee coil in order to evaluate the articular cartilage of the knee joint
- Tez No: 366149
- Danışmanlar: PROF. DR. MEHMET ALİ YİNANÇ
- Tez Türü: Tıpta Uzmanlık
- Konular: Radyoloji ve Nükleer Tıp, Radiology and Nuclear Medicine
- Anahtar Kelimeler: 3.0 T- 1.5 T MR, Kartilajı Görüntüleme, 3.0 T Komposizyonel MR, T1 mapping, Diz, Diz eklemi, Kıkırdak, Kıkırdak hastalıkları, Manyetik rezonans görüntüleme, Radyografi, 1.5 T MR-3.0 T MR Compare, Cartilage Imaging, 3.0 T Compositional MR, T1 mapping, Knee, Knee joint, Cartilage, Cartilage diseases, Magnetic resonance imaging, Radiography
- Yıl: 2014
- Dil: Türkçe
- Üniversite: Ufuk Üniversitesi
- Enstitü: Tıp Fakültesi
- Ana Bilim Dalı: Radyoloji Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Amaç: Bu çalışmanın amacı, 3 T MR'da 15 kanallı verici-alıcı (transmitreceive) diz koyili ve morfolojik - kompozisyonel görüntüleme sekansları ile elde edilen imajların, diz eklemi kartilaj defektlerini göstermedeki tanısal performansını, rutin 1.5 T protokoller ile karşılaştırmak ve üstünlüğünü saptamaktır. Gereç ve Yöntem: Altı aydan kısa bir zaman aralığında aynı dize yönelik olarak 1.5 T ve 3.0 T MR incelemesi yapılan, artroskopi sonuçları olan 9 hasta retrospektif olarak belirlendi. MR inceleme protokolleri 3.0 T'da 3D PDW-SPACE, 3D STIR-SPACE; 1.5 T'da 2D T1W TSE, 3D PDW, 2D Dual TSE, 2D PDW TSE, 2D T2W TSE sekanslarından oluşmaktaydı. İki radyolog tarafından tüm kartilaj defektlerinin diz eklemindeki anatomik lokalizasyonu ve grade'lemesi ICRS 'Cartilage Injury Evaluation Package'e göre; sinovyal kavitedeki efüzyon ve eklem yüzlerindeki ödem Whole-Organ MRI Score (WORMS)'a göre yapıldı. Kartilaj defektlerinin maksimum boyutları ve derinliği sagittal imajlardan ölçüldü. Çalışmada gözlemciler içi ve gözlemciler arası uyum Cohen'in kappa katsayısı ve sınıf içi korelasyon katsayısı hesaplanarak incelenmiştir. Analizler SPSS (Statistical Package for Social Sciences) v21 programında yapılmış olup p<0.05 istatistiksel olarak anlamlı kabul edilmiştir. Bulgular: Çalışma grubu toplamda 12 kartilaj defektinin izlendiği 9 hastadan (2 kadın, 7 erkek; ortalama yaş 39,6 yıl) oluşmaktaydı. Kartilaj defektlerinin grade'lenmesinde, 3.0 T MR protokolü standart referans ile daha yüksek uyum düzeyine sahipti (3.0 T p<0.001; 1.5 T p= 0.126); gözlemci içi uyum 3.0 T'da daha yüksekken (3.0 T = 1.00; 1.5 T = 0.86), gözlemciler arasındaki uyum her iki protokolde de aynı düzeydeydi. Eklem yüzlerindeki defektlerin belirlenmesi açısından 1.5-T ve 3.0-T MR protokollerinde gözlemci içi (sırasıyla kappa = 0.81 / 1.00; sırasıyla p = 0.001 / 0.001) ve gözlemciler arasında (sırasıyla kappa = 1.00 / 0.64; sırasıyla p = 0.001 / 0.018) anlamlı uyumluluk bulundu. Standart referans ile 1.5-T MR ve 3.0-T MR protokolleri konsensus verileri arasında anlamlı uyumluluk izlenmedi (sırasıyla kappa = 0.00 / 0.33; sırasıyla p = 1.00 / 0.121). Kartilaj 59 defektlerinin koronal ve sagittal imajlarda lokalizasyonunun belirlenmesinde 3.0 T MR artroskopi ile daha yüksek uyum düzeyi gösterdi; ancak gözlemci içi ve gözlemciler arası uyum düzeyi her iki protokolde de benzerdi. Sonuç: Rutin 1.5 T MR protokolü ile karşılaştırıldığında, 3.0 T MR morfolojik ve kompozisyonel değerlendirme protokolü diz eklemi kartilaj lezyonlarının değerlendirilmesinde tanısal performansı artırmaktadır.
Özet (Çeviri)
Purpose: The purpose of this study is to compare the diagnostic performance of morphological and compositional 3T MR imaging with standart 1.5 T MR protocol for evaluating the articular cartilage of the knee joint. Material and methods: Nine patients were identified retrospectively as having 1.5 T and 3.0 T MR studies of the same knee within an average of 6 mounths and also had been undergone knee arthroscopy at the time of study. MR imaging protocols consisted of 2D T1 Mapping, 3D PDW-SPACE, 3D STIR-SPACE at 3.0 T, and 2D T1W TSE, 3D PDW, 2D Dual TSE, 2D PDW TSE, 2D T2W TSE at 1.5 T. All cartilage defects were localised and graded by using ICRS 'Cartilage Injury Evaluation Package'; the effusion of synovial cavity and bone marrow edema of articular surfaces were graded by using Whole-Organ MRI Score (WORMS) by two radiologists. The maximum size and depth of cartilage defects were measured on sagittal images. Intraobserver and interobserver variability of each protocol, also the variability between reference standart and consensus was determined by intraclass correlation coefficient (ICC) and kappa statistics. Results: Nine patients (2 women, 7 men; mean age 39.6 years) ,with 12 cartilage defects totally, were included in the study. In order to grade cartilage defects, 3.0 T had better agreement with arthroscopy as a standart of reference (3.0-T p<0.001; 1.5-T p= 0.126). Intraobserver agreement was higher at 3.0 T (3.0-T = 1.00; 1.5-T = 0.86), but not interobserver agreement for grading cartilage defects. For depicting cartilage defects on articular surfaces, there was statistically significant intraobserver (1.5-T and 3.0-T respectively 0.81/ 1.00; 1.5-T and 3.0-T respectively p = 0.001 / 0.001) and interobserver (1.5-T and 3.0-T respectively = 1.00 / 0.64; p = 0.001 / 0.01) agreement with both 1.5-T and 3.0-T MR protocols. There was not statistically significant agreement between standart reference and consensus with both protocols (1.5-T and 3.0-T respectively kappa = 0.00 / 0.33; p = 1.00 / 0.121). 61 For localising defects on coronal and sagittal images 3.0 T had better agreement with standart reference (1.5-T and 3.0-T respectively, coronal plane = 0.47 versus 0.67; sagittal plane = 0.49 versus 0.61), intra and interobserver agreements were similar. Conclusion: Compared to routine 1.5 T MR protocol, 3.0 T morphological and compositional MR protocol has improved diagnostic performance for evaluating the articular cartilage defects of the knee.
Benzer Tezler
- 4x1 MIMOompact half duplex RF T / R module with high resolution in 130 nm SiGe BiCMOS for 5G applications
5G uygulamaları için 130 nm SiGe BiCMOS'da yüksek çözünürlüklü 4x1 MIMO kompakt yarım dubleks RF T / R modülü
ABDURRAHMAN BURAK
Doktora
İngilizce
2021
Elektrik ve Elektronik MühendisliğiSabancı ÜniversitesiElektronik Mühendisliği Ana Bilim Dalı
PROF. DR. YAŞAR GÜRBÜZ
- FPGA tabanlı şifreli kablosuz haberleşme sistemi
FPGA based encrypted wireless communication system
ILGAZ AZ
Yüksek Lisans
Türkçe
2014
Elektrik ve Elektronik Mühendisliğiİstanbul Teknik ÜniversitesiAna Bilim Dalı (disiplinlerarası)
DOÇ. DR. GÖKHAN İNALHAN
- Bilişsel radyo ağları için uzaysal modülasyonlu spektrum paylaşım protokolleri
Spatially modulated spectrum sharing protocols for cognitive radio networks
SEDA ÜSTÜNBAŞ
Yüksek Lisans
Türkçe
2017
Elektrik ve Elektronik Mühendisliğiİstanbul Teknik ÜniversitesiElektronik ve Haberleşme Mühendisliği Ana Bilim Dalı
PROF. DR. HASAN ÜMİT AYGÖLÜ
- GNSS sistemleri için küçük boyutlu yama anteni ve kompakt anten dizisi tasarımı
Design of a compact patch antenna and antenna array for GNSS systems
MUHAMMED YUSUF ŞAHİN
Yüksek Lisans
Türkçe
2025
Elektrik ve Elektronik Mühendisliğiİstanbul Teknik ÜniversitesiElektronik ve Haberleşme Mühendisliği Ana Bilim Dalı
PROF. DR. MESUT KARTAL
- ISDN uçbirimi veri kapısı arabirimi yazılımı
ISDN terminal equitment data port interface module software
DEĞER ÇINAR
Yüksek Lisans
Türkçe
1990
Bilgisayar Mühendisliği Bilimleri-Bilgisayar ve Kontrolİstanbul Teknik ÜniversitesiPROF.DR. A. EMRE HARMANCI