Dental implant içine yerleştirilen farklı konsantrasyonlarda klorheksidin ve polimer oranına sahip jellerin implant içi bakteriyel üreme üzerine kısa ve uzun dönem etkilerinin in vitro olarak incelenmesi

In vitro examination of short and long term effects of gels with varying clorhexidine to polymer concentration ratios installed into dental implants on bacterial growth within the implant

  1. Tez No: 383171
  2. Yazar: SEÇİL ÇOPUROĞLU
  3. Danışmanlar: DOÇ. DR. ALPER AKTAŞ
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2015
  8. Dil: Türkçe
  9. Üniversite: Hacettepe Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Ağız, Diş, Çene Hastalıkları ve Cerrahisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 171

Özet

Bu çalışmada farklı konsantrasyonlarda klorheksidin glukonat ve kitosan içeriğine sahip jellerin, dental implantlarda mikrosızıntı ve bakteriyel üreme üzerine etkisinin değerlendirilmesi amaçlanmıştır. Her biri beşer adet implanttan oluşan beş grup planlanmıştır. Çalışma grupları; %1.5 kitosan - %1 klorheksidin glukonat, %1.5 kitosan - %2 klorheksidin glukonat, %2 kitosan-%1 klorheksidin glukonat, %2 kitosan - %2 klorheksidin glukonat şeklindedir. İlgili gruptaki jel, implantın içine uygulanarak iyileşme başlığı kapatılmış; kontrol grubunda ise implantın içine steril besiyeri uygulanmıştır. Tüm implantlar Staphylococcus Aureus içeren besiyerinde inkübe edilmiştir. 1 hafta sonra implantların içinden kağıt koni ile örnek alınarak besiyerine ekim yapılmış; sonuçlar bakteriyel üreme var ya da yok şeklinde değerlendirilmiştir. Aynı işlemler 4, 8, 12. haftalarda tekrarlanmıştır. Bakteriyel kültür sonucunda 1. ve 4. haftalarda, tüm jellerin kontrol grubuna göre belirgin antibakteriyel etki gösterdiği görülmüştür. 8. haftada % 1 klorheksidin glukonat - %1,5 kitosan içeren jelin etkinliğinin azaldığı görülürken diğer jellerin etkinliğinin 12 hafta boyunca değişmediği izlenmiştir. Zamandan bağımsız olarak bakıldığında ise % 2 klorheksidin glukonat içeren jellerin %1 klorheksidin glukonat içeren jellerden daha yüksek antibakteriyel etki gösterdiği görülmüştür. Çalışmamızın sonucunda, özellikle %2 klorheksidin glukonat içeriğine sahip jeller ile, peri-implant kemik kaybının en hızlı olduğu erken dönemde, bakteriyel mikrosızıntının önlenebileceği in vitro olarak gösterilmiştir.

Özet (Çeviri)

In this study, effects of gels with varying chlorhexidine gluconate to chitosan ratios on microleakage at dental implants and bacterial growth are evaluated. Five groups were planned and each group consisted of five implants. Four different formulations were prepared for test groups. Chlorhexidine gluconate and chitosan concentrations of the formulations were; 1.5% chitosan - 1% chlorhexidine gluconate, 1.5% chitosan-2% chlorhexidine gluconate, 2% chitosan - 1% chlorhexidine gluconate and 2% chitosan- 2% chlorhexidine gluconate. Each of the gels was installed in five implants. Sterile medium was installed in implants for the control group. All implants were embedded in medium containing Staphylococcus Aureus and incubated for one week. Samples were collected from the internal part of the implants by using a paper point at the end of one week and the paper points were cultivated. Bacterial growth was evaluated according to the presence of bacterial colonies. All procedure was repeated for 4, 8, 12 weeks. According to the bacterial cultivation results, all formulations prevented bacterial growth in the internal cavity of implants along 1 and 4 weeks. Antibacterial effect of formulation containing 1% chlorhexidine gluconate-1, 5% chitosan diminished after 4 weeks while other formulations protected their antibacterial effect for 12 weeks. Gels containing 2% chlorhexidine gluconate showed stronger antibacterial activity than gels containing 1% chlorhexidine gluconate. At the end of this in vitro study, it was shown that a bacteria free environment can be obtained in the internal cavity of the implants by using gels containing 2 % chlorhexidine gluconate for early period of healing when rapid peri-implant bone resorption occurs.

Benzer Tezler

  1. Dental implantların 2 farklı teknik olan piezocerrahi osteotomi ve novel osseodensifikasyon yöntemiyle yerleştirildikten sonra implantların osseointegrasyonu üzerine etkilerinin değerlendirilmesi: Tavşan tibiasında deneysel çalışma

    Evaluation of the effects of dental implants on the osseointegration of implants after placing with 2 different technique of piezosurgery osteotomy and novel osseodensification method: Experimental study in rabbit tibia

    MURAT ARSLAN

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2019

    Diş HekimliğiSivas Cumhuriyet Üniversitesi

    Ağız Diş ve Çene Cerrahisi Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ TURGAY PEYAMİ HOCAOĞLU

  2. İmplant yuvası açılmasında oluşan ısının ın-vıtro değerlendirilmesi

    The in ? vitro evaluation of heat production during implant preparation

    AHMET FERHAT MISIR

    Doktora

    Türkçe

    Türkçe

    2008

    Diş HekimliğiOndokuz Mayıs Üniversitesi

    Ağız, Diş, Çene Hastalıkları ve Cerrahisi Ana Bilim Dalı

    DOÇ. DR. MAHMUT SÜMER

  3. İmplant uygulamasının çene kemiğinde sebep olduğu mekanik ve ısıl değişimlerin incelenmesi

    Investigation of mecanical and thermal variation caused in the jawbone of implantology

    BUKET TURGUT

    Yüksek Lisans

    Türkçe

    Türkçe

    2016

    Makine MühendisliğiErciyes Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    PROF. NECDET ALTUNTOP

  4. Dental implantların tekrar kullanılabilirliğinin deneysel olarak araştırılması

    Experımental research about reusabılıty of dental ımplants

    MURAT ULU

    Doktora

    Türkçe

    Türkçe

    2011

    Diş HekimliğiErciyes Üniversitesi

    Ağız, Diş, Çene Hastalıkları ve Cerrahisi Ana Bilim Dalı

    YRD. DOÇ. DR. ERDEM KILIÇ

  5. Sabit protezlere uygulanan statik yüklerin dental implantlarda oluşturduğu deformasyon değerlerinin in vitro koşullarda incelenmesi

    In Vitro evaluation of the deformation values of dental implants supporting fixed bridges under static loading conditions

    MURAT CAVİT ÇEHRELİ

    Doktora

    Türkçe

    Türkçe

    2000

    Diş HekimliğiHacettepe Üniversitesi

    Protez Ana Bilim Dalı

    DOÇ. DR. HALDUN İPLİKÇİOĞLU