Geri Dön

Konformal ve yoğunluk ayarlı radyoterapi teknikleri ile yapılan meme ışınlamalarında fetüs dozunun araştırılması

Made with conformal and intensity modulated radiotherapy techniques in breast irradiation investigation of the dose to the fetus

  1. Tez No: 391081
  2. Yazar: AKIN ÖĞRETİCİ
  3. Danışmanlar: PROF. DR. HATİCE BİLGE
  4. Tez Türü: Yüksek Lisans
  5. Konular: Fizik ve Fizik Mühendisliği, Onkoloji, Physics and Physics Engineering, Oncology
  6. Anahtar Kelimeler: Meme kanseri, Hamilelik, Fetüs, Alan dışı doz, TLD, Kurşun önlük, Gebelik, Kurşun, Meme neoplazmları, Neoplazmlar, Radyasyon, Radyasyon dozajı, Radyoterapi, Radyoterapi-bilgisayar yardımlı, Breast cancer, Pregnancy, Fetus, Peripheral Dose, TLD, Lead vest, Lead, Breast neoplasms, Neoplasms, Radiation, Radiation dosage, Radiotherapy, Radiotherapy-computer assisted
  7. Yıl: 2015
  8. Dil: Türkçe
  9. Üniversite: İstanbul Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Temel Onkoloji Ana Bilim Dalı
  12. Bilim Dalı: Sağlık Fiziği Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Meme kanserindeki artış ve görüldüğü yaş ortalamasının azalması, hastaların radyoterapi aldığı sırada hamile olma olasılığını oldukça yükseltmiştir. Hücrelerinin bölünme hızı ve farklılaşma özelliklerine bağlı olarak, embriyo ve fetüs radyasyona fazlasıyla duyarlı dokulara sahiptir. Özellikle vücut gelişimlerinin büyük oranda tamamlandığı hamilelik süreci boyunca maruz kaldıkları radyasyon, fetüsün organ gelişimine ve hayatı boyunca karşılaşabileceği kanser riskine önemli miktarda etki etmektedir. Çalışma meme kanseri nedeniyle radyoterapi alan gerçek hastayı taklit eden bir fantom üzerinde gerçekleştirilmiştir. Fantom, Varian Clinac 600 DBX doğrusal hızlandırıcı ile standart planlara uygun olarak konformal ve IMRT yöntemiyle ışınlanmıştır. Işınlanan fantomun fetüsün bulunduğu kabul edilen rahim bölgesinden Termoluminesans dozimetreler yardımıyla ölçümler alınmıştır. Alınan ölçümler hem Tedavi Planlama Sistemi (Eclipse), hem de kendi aralarında karşılaştırılmıştır. Tedavi yöntemlerinin karşılaştırılmasının yanı sıra, tedavilerde kurşun önlük kullanımı ve hasta boyunun 5 santimetre daha kısa olmasının, fetüsün alacağı dozda yaratacağı farklılıklar da incelenmiştir. Ölçümlere göre fetüsün IMRT yönteminde, konformal ışınlama sonucunda maruz kalınandan yaklaşık 5 kat daha fazla radyasyon dozu aldığı tespit edilmiştir. Bu ölçümler Tedavi Planlama Sisteminde hesaplanamamıştır. Ayrıca kurşun önlük kullanımının konformal ışınlamalarda fetüs dozunu biraz arttırırken, IMRT yöntemi için biraz azalttığı görülmüştür. Fetüs ile ışınlama arasındaki mesafe kısaldıkça fetüsün maruz kalacağı dozun arttığı teorisi de pratik olarak kanıtlanmıştır.

Özet (Çeviri)

The possibility of a patient being pregnant during breast radiotherapy has significantly boosted, due to increase of breast cancer cases and decrease of the mean age of subjects. Fetus has several radio-sensitive tissues according to their cell mitotic rate and differentiation properties. Therefore the fetal radiation exposure, especially in pregnancy period when body development is mostly brought to completion, can highly alter the organogenesis and cancer risk throughout its life. This research has been done with a phantom that simulates a real radiotherapy patient with breast cancer. Phantom has been treated with Varian Clinac 600 DBX linear accelerator according to standart planning of conformal and IMRT methods. Treated phantom had thermoluminesence dosimeters in the region, where uterus was assumed to be and as such measurements were taken. The measurements have been compared among themselves and with Treatment Planning System (Eclipse) data. Besides the comparison of treatment methods, fetal dose differences have been investigated in application of lead vests during treatment and also when patient height was lower than normal by 5 centimeters. Measurement data shows clearly that fetus is absorbing 5 times more radiation dose in IMRT method, than it is exposed to in conformal therapy. It is also evident that Treatment Planning System is not able to calculate such data. In addition to these, application of lead vest proved to be useful in lessening the fetal dose for IMRT method, while increasing the dose slightly in conformal treatment. Theoretical assumption of increasing fetal dose with less fetus - radiation treatment field distance has also been verified practically.

Benzer Tezler

  1. Geniş alan göğüs duvarı ışınlamalarında hedef ve riskli organ hacimlerinin aldığı dozun farklı ışınlama teknikleri açısından karşılaştırılması

    Comparison of doses received by the target volume and the organs at risk in wide area chest wall irradiation in terms of different irradiation tecniques

    HASAN KADİRCAN ALKAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2016

    OnkolojiHarran Üniversitesi

    Sağlık Fiziği Ana Bilim Dalı

    PROF. DR. AHMET BOZKURT

  2. Hidrofoillerde derinlik ve kat-kat etkisinin incelenmesi

    An Investigation of depth and cascade effect on hydrofoils

    AYDIN ŞALCI

    Doktora

    Türkçe

    Türkçe

    1984

    Gemi Mühendisliğiİstanbul Teknik Üniversitesi

    PROF. DR. KEMAL KAFALI

  3. Kompakt riemann yüzeylerinde riemann-roch teoremi ve bazı sonuçları

    Başlık çevirisi yok

    NACİ ALKIŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    MatematikAnadolu Üniversitesi

    Matematik Ana Bilim Dalı

    YRD. DOÇ. DR. COŞKUN TAYFUR

  4. Toplu konutlarda kullanıcı-konut kullanıcı-çevre ilişkileri ve sorunları

    Başlık çevirisi yok

    RECEP DÜZENLİ

    Yüksek Lisans

    Türkçe

    Türkçe

    1988

    MimarlıkKaradeniz Teknik Üniversitesi

    Mimarlık Ana Bilim Dalı

    DOÇ. DR. SALİHA AYDEMİR