Geri Dön

Klima santrallerinde kullanılan V profil delikli difüzörlü hücrenin akış performansının sayısal ve deneysel olarak incelenmesi

Numerical and experi̇mental investigation of flow performance of unit with V profile perforated diffuser used in air handling units

  1. Tez No: 424347
  2. Yazar: EKREM TAÇGÜN
  3. Danışmanlar: PROF. DR. SUAT CANBAZOĞLU
  4. Tez Türü: Yüksek Lisans
  5. Konular: Mühendislik Bilimleri, Engineering Sciences
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2016
  8. Dil: Türkçe
  9. Üniversite: İnönü Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Makine Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Termodinamik Bilim Dalı
  13. Sayfa Sayısı: 93

Özet

Klima santralleri enerjiyi çok fazla harcayan iklimlendirme sistemleridir. Günümüzde enerji verimliliğinin son derece önemli olduğundan klima sanrtalleri için optimizasyon çalışmaları yapmak kaçınılmaz bir durumdur. Tükenmekte olan enerji kaynakları ve çevre kirliliğinden dolayı enerjiyi verimli kullanmak çok büyük bir önem arz etmektedir. Bu çalışmada bazı klima santrali üreticileri tarafından kullanılmakta olan V profil delikli difüzör (yayıcı) santral elemanının, akış analizi ve basınç düşümü optimizasyonu yapılmıştır. Santral hücresindeki difüzörün, hem sayısal hem de deneysel olarak basınç düşümleri hesaplanmış ve karşılaştırmaları yapılmıştır. Ayrıca model bir difüzör tasarlanmış, uygun geometrik ve akış parametreleriyle optimizasyonu yapılmıştır. Çalışmanın sonucunda optimum difüzör ve akış özelliğiyle ne kadarlık bir enerji kazancı sağlanacağı hesaplanmıştır. Böylelikle amaçlanan enerji verimliliği gerçekleştirilmiştir. Difüzörün kendisinin kullanılması santral boyutunu kısaltacağından dolayı ilk yatırım maliyeti ekonomiktir. Bunun olmasının yanı sıra, optimum difüzör kullanarak, basınç düşümleri azaltılmıştır ve işletme maliyeti için de ekonomiklik sağlanmıştır. Bu tezde, sayısal çalışmalar için uygulamada sıklıkla kullanılan Hesaplamalı Akışkanlar Dinamiği (HAD) yazılımı olan ANSYS-Fluent 14.5 paket programı kullanılmıştır. Sayısal akış analizlerinde Standart k-ε türbülans modeli seçilmiştir. Seçilen türbülans modeli deneysel olarak doğrulanmıştır. Optimizasyon yöntemi için de Taguchi Optimizasyon Yöntemi kullanılmıştır. Bu yöntem ile yapılması gereken çok sayıda analiz sayısı azaltılmıştır. Bu çalışmada, tasarlanan V profil delikli difüzörün belirli akış hızlarında enerji kazancı sağladığı görülmüştür. Klima santrali üreticileri için tasarlanan bu difüzörün, enerji verimliliği sağlayarak, faydalı olacağı anlaşılmıştır. ANAHTAR KELİMELER: Eneji verimliliği, delikli difüzör, HAD, Taguchi optimizasyon Yöntemi

Özet (Çeviri)

Air Handling Units (AHU) are an air conditioner systems that consume energy too much. Making optimisation working for AHU is essential situation because energy efficiency is quite important todays. Using energy efficiently is very significant due to consumption energy resource and environmental pollution. In this study, the flow analysis and pressure dropped optimisation in perforated diffuser AHU element using by some AHU manufacturer were carried out. Cabin of the unit and diffuser were computed pressure drop with numerical and experimental and they were compared. Moreover a pattern diffuser was designed and it was made optimisation with proper geometric and flow parameter. Conclusion of studying, how much energy gain was computed with optimum diffuser and flow properties. In this way objective energy gain was achieved. For using diffuser itself shorten unit lenght initial investment cost is economic. Besides pressure dropped were reduced with using optimum diffuser and economic was provided for operating costs. In this thesis, for numerical studying, ANSYS-Fluent 14.5 packaged software what frequently used in practice as a software of the Computational Fluid Dynamics (CFD) was used. k-ε turbulence model was choosen for numerical flow analysis. Turbulent model was validated experimentally. Also for optimisation method, Taguchi Optimisation method was used. With this method, a lot of essential analysis were reduced. In this study, designed perforated diffuser was observed providing energy gain at certain flow velocity. This diffuser what designed for AHU manufacturer will be usefull how it provides energy efficiency KEYWORDS: Energy Efficiency, perforated diffuser, CFD, Taguchi Optimisation Method,

Benzer Tezler

  1. Merkezi klima santrallerindeki boş hücreler için tasarlanan bazı difüzörlerin akışa etkisi

    Investigation of the effect of on the flow the some diffuser types in empty cells

    AHMET VAKKAS VAKKASOĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    2019

    Makine MühendisliğiKahramanmaraş Sütçü İmam Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    PROF. DR. AHMET KAYA

  2. Klima santrallerinde kullanılan delikli difüzörlü boş hücredeki hava akışının akış ve akustik açıdan incelenmesi

    Investigation of airflow in empty chambers with perforated diffuser designed for air handling units in terms of flow and acoustic

    AHMET ERDOĞAN

    Doktora

    Türkçe

    Türkçe

    2017

    Makine Mühendisliğiİnönü Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    DOÇ. DR. İSHAK GÖKHAN AKSOY

  3. Klima santrallerinde kullanılan filtrelerin akış ve basınç düşümüne olan etkilerinin incelenmesi

    Investigation of the effects of filters used in air conditioning units on flow and pressure drop

    TUNCAY TEKBIYIK

    Yüksek Lisans

    Türkçe

    Türkçe

    2022

    Makine MühendisliğiKahramanmaraş Sütçü İmam Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    PROF. DR. AHMET KAYA

  4. Merkezi klima santrallerindeki boş hücreler için tasarlanan kesik piramit tip difüzörlerin akış dağılımına etkisinin sayısal olarak incelenmesi

    Numerical investigation of the effect of fitted pyramid type diffusers designed for empty cells in central air handling units on flow distribution

    EBRU BİLİCİ

    Yüksek Lisans

    Türkçe

    Türkçe

    2022

    Makine MühendisliğiKahramanmaraş Sütçü İmam Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    PROF. DR. AHMET KAYA

  5. Yüksek katlı binalarda klime tesisatında ısı geri kazanım sistemlerinin araştırılması

    Heat recovery by climate systems on the skycrapers

    MUHSİN FATİH KAHRAMAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2003

    Makine MühendisliğiYıldız Teknik Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    DOÇ. DR. ZEYNEP DÜRİYE BİLGE