Yoğunluk ayarlı radyoterapi uygulamalarında hasta planlarının kalite kontrollerinde iki farklı dozimetrik sistemin araştırılması

Investigation of the quality assurance of patient treatment plans via two different dosimetic systems at intensity modulated radiation therapy applications

  1. Tez No: 431781
  2. Yazar: SEDA ŞAHİN
  3. Danışmanlar: PROF. DR. HATİCE BİLGE BECERİR
  4. Tez Türü: Yüksek Lisans
  5. Konular: Fizik ve Fizik Mühendisliği, Onkoloji, Physics and Physics Engineering, Oncology
  6. Anahtar Kelimeler: Yoğunluk Ayarlı Radyasyon Tedavisi, 2D-Array seven29, MapCHECK 2, Gama Analizi, Intensity Modulated Radiation Therapy, 2D-Array seven29, MapCHECK 2, Gamma analysis
  7. Yıl: 2016
  8. Dil: Türkçe
  9. Üniversite: İstanbul Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Temel Onkoloji Ana Bilim Dalı
  12. Bilim Dalı: Sağlık Fiziği Bilim Dalı
  13. Sayfa Sayısı: 94

Özet

IMRT tekniği kullanılan tedavi planlarında, radyasyon yoğunluğu demet boyunca değiştiğinden; hedefe maksimum tedavi dozu uygulanırken, hedefin çevresindeki sağlıklı dokular ve kritik organlar mümkün olan en üst düzeyde korunur. Bu teknikte kısa mesafede doz değişiminin yüksek olması ve tedavilerin kompleks olması nedeniyle, planlar hastaya aktarılmadan önce kalite kontrol aşamasından geçmelidir. Bu çalışmada, Eclipse V10 Tedavi Planlama Sisteminde (TPS), 20 Larenks hastasının IMRT planlarının kalite kontrolleri iki farklı dozimetrik ölçüm sistemi kullanılarak değerlendirilmiştir. Ölçümler RW3 katı su fantomunda, tüm gantry, kolimatör ve masa açıları 00'de ve tüm alanlar birlikte (composite) olacak şekilde, 2D-Array seven29 ve MapCHECK 2 dozimetrik ölçüm sistemleri kullanılarak, Varian DHX lineer hızlandırıcısında yapılmıştır. 2D-Array seven29 ile alınan ölçümler PTW Verisoft 6.0.2 yazılımı aracılığıyla, MapCHECK 2 ile alınan ölçümler ise SNC Patient 6.0 yazılımı aracılığıyla gama analiz yöntemi kullanılarak değerlendirilmiştir. Ölçülen ve hesaplanan doz akı haritalarına ait gama analiz değerleri, %2DD–2mm DTA, %3DD–3mm DTA, %3DD–3,5mm DTA, %3DD–4mm DTA ve %4DD–3mm DTA kriterlerinde düşük dozun %5 ve %10'u baskılanarak analiz edilmiştir. Çalışmanın sonucunda, %2DD–2mm DTA kriterlerine göre iki ölçüm sisteminde de gama analiz değerlerinin %85 seviyesinde olduğu, diğer tüm kriterlerde bu değerin %95'in üzerinde olduğu, %2DD–2mm DTA değerlendirme kriteri haricindeki diğer gama analizi değerlendirmelerinde, iki ölçüm sistemi arasında anlamlı bir fark olmadığı görülmüştür.

Özet (Çeviri)

Intensity Modulated Radiation Therapy (IMRT) is an advanced technique that provides protecting surrounding healthy tissues while giving the highest possible treatment dose to the tumor region since the intensity of the radiation differs through the bunch. Because of the complexity of treatment planning and high divergence of the absorbed dose in the treatment area, it is an obligation to make quality assurance tests of the treatment plans before the first practice. In this study, 20 IMRT treatment plans of larynx patients prepared on Eclipse Treatment Planning System (Version 10.0) and evaluated via two different dosimetric systems. The measurements were taken as a composite field on RW3 solid water phantom by setting all gantry, collimator and table angles to zero at Varian DHX linear accelerator. 2-D Array seven29 and MapCHECK 2 dosimetric measurement systems were used in this evaluation via PTW Verisoft 6.0.2 and SNC Patient 6.0 software, respectively. Gamma analysis of the calculated and measured dose maps were investigated for supressed low dose regions of 5% and 10% at the following criterias: 2DD%‒2mm DTA, 3DD%‒3mm DTA, 3DD%‒3,5mm DTA, 3DD%‒4mm DTA and 4DD%‒3mm DTA. As a result of the gamma analysis, we found that all treatment plans had the necessary 95% agreement for calculated and measured dose fluence maps on both measurement tools, except for 2DD%‒2mm DTA which was 85%. Thus, it can be said that there is no significant difference was observed between these two dose measurement systems for larger criterias than 2DD%‒2mm DTA due to our study.

Benzer Tezler

  1. Akciğer tümörlerinde yoğunluk ayarlı ark radyoterapi tekniği kullanılarak iki farklı optimizasyon algoritmasının doz dağılımına etkisinin incelenmesi

    Investigation of two different doses distribution optimization algorithm in lung tumors using with intensity modulated arc radiotherapy technique

    GÖRKEM ÇEVİKBAŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    2016

    Onkolojiİstanbul Üniversitesi

    Temel Onkoloji Ana Bilim Dalı

    PROF. DR. HATİCE BİLGE BECERİR

  2. Düşük risk prostat kanserinde yoğunluk ayarlı fraksiyone radyoterapi ile stereotaktik vücut radyoterapisinin dozimetrik karşılaştırılması

    Dosimetric comparison of intensity-modulated fractional radiotherapy and stereotactic body radiotherapy in low-risk prostate cancer

    ONUR SANCAR

    Yüksek Lisans

    Türkçe

    Türkçe

    2023

    Radyasyon OnkolojisiKaradeniz Teknik Üniversitesi

    Sağlık Fiziği Ana Bilim Dalı

    DOÇ. DR. EMEL HACIİSLAMOĞLU

  3. Baş-boyun kanserli hastaların adaptif radyoterapisinde cone beam CT (CBCT) üzerinden yapılan planların dozimetrik değerlendirilmesi

    Dosimetric evaluation of treatment plans made with images gained from cone beam CT in patients with head and neck cancer undergoing adaptive radiotherapy

    YILDIRAY ÖZGÜVEN

    Doktora

    Türkçe

    Türkçe

    2024

    Radyasyon OnkolojisiTrakya Üniversitesi

    Sağlık Fiziği Ana Bilim Dalı

    PROF. DR. HASAN MURAT ÇALOĞLU

  4. Yoğunluk ayarlı radyoterapi tekniği kullanılarak tedavi edilen baş-boyun kanserli hastaların tedavi planlarının dozimetrik olarak incelenmesi

    Dosimetric investigation of treatment plans of head and neck cancer patients who were treated by using intensity modulated radiation therapy technique

    ŞİLEM YÜCE

    Yüksek Lisans

    Türkçe

    Türkçe

    2012

    Fizik ve Fizik MühendisliğiUludağ Üniversitesi

    Radyasyon Onkolojisi Ana Bilim Dalı

    PROF. DR. GÖKAY KAYNAK

  5. Yoğunluk ayarlı radyoterapi uygulamaları için kullanılan doz ölçüm doğrulama sistemlerinin karşılaştırılması

    Comparison of dose verification systems used for IMRT QA

    EZGİ IŞIKTAŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    2011

    Fizik ve Fizik MühendisliğiDokuz Eylül Üniversitesi

    Medikal Fizik Ana Bilim Dalı

    PROF. DR. FADİME AKMAN

    ÖĞR. GÖR. ZAFER KARAGÜLER