Baş boyun kanserlerinde uygulanan volumetrik ark tedavisi (vmat) planlarının nitelik güvenirliğinde farklı sistemlerin karşılastırılması
Comparison of different systems for quality assurance applied volumetric arc therapy (VMAT) plans in head and neck cancer
- Tez No: 452241
- Danışmanlar: PROF. DR. FADİME AKMAN, YRD. DOÇ. DR. KADİR AKGÜNGÖR
- Tez Türü: Yüksek Lisans
- Konular: Onkoloji, Oncology
- Anahtar Kelimeler: baş boyun kanseri, VMAT, nitelik güvenirliği sistemleri, gama analizi, head and neck cancer, VMAT, quality assurance systems, gamma analysis
- Yıl: 2016
- Dil: Türkçe
- Üniversite: Dokuz Eylül Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Medikal Fizik Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: 51
Özet
Amaç: Hacim Ayarlı Ark Terapi (Volume Modulated Arc Therapy (VMAT)) nitelik güvenirliğinde kullanılan farklı doz doğrulama sistemlerini güvenilirlik ve uygulanabilirlik açısından birbirleriyle, dozimetrik açıdan tedavi planlama sistemi (TPS) ile karşılaştırıldı. Gereç ve Yöntem: Çalışmada, Dokuz Eylül Üniversitesi Hastanesi Radyasyon Onkolojisi Bölümünde yerel ileri evre baş boyun kanseri (BBK) tanısıyla Eclipse Tedavi Planlama Sisteminde VMAT plan yapılmış ve uygulanmış 31 hasta verisi arşivden seçildi. Uygulanmış VMAT planlarının doğruluğunu kontrol etmek için ArcCHECK, EPID ve EPIQA nitelik güvenirliği (QA) sistemleri kullanıldı. Her bir hasta için QA planları tüm nitelik güvenirlik sistemleri için Eclips TPS'nde alanların gantri, kolimatör ve masa açıları uygun pozisyona getirilerek oluşturuldu. Kullanılan QA sistemleri için yapılan planlar TrueBeam cihazı ile ışınlandı. Işınlama ile doz akı haritaları elde edildi. Ölçümler ve hesaplamalar doz farkı %3, doz mesafe uyumu 3mm kriterlerine göre gama indeksiyle değerlendirilerek karşılaştırıldı. İstatistik analizler SPSS Versiyon 24 programında Korelasyon analizi ve Sample Paired T-testi kullanılarak yapıldı. Bulgular: Ölçümlerde ArcCheck, EPID ve EPIQA'nın gama analizi yöntemiyle elde edilen sonuçların TPS ile arasındaki uyum ortalaması sırasıyla %98,41 (94,9-100) (±1,700), %99,70 (98,6-100) (±0,329), %96,78 (86,7-99,32) (±2,893) olarak hesaplandı. Gama analizi sonucuna göre ArcCheck ve EPIQA ile yapılan ölçümlerden iki tanesi % 95 kabul sınırını geçememiştir fakat ArcCheck ile elde edilen sonuçlar bu değere çok yakın bulunmuştur. Bunun yanında EPID ile yapılan ölçümlerin tamamı % 95 kabul sınırını üzerindedir. Korelasyon analizi ile elde edilen r değerleri ArcCheck ile EPID'nın karşılaştırılmasında 0,506, EPID ile EPIQA' nın karşılaştırılmasında 0,132, ArcCheck ile EPIQA' nın karşılaştırılmasında 0,203 bulunmuştur. Sonuç: Lokal ileri evre baş boyun kanserlerinde VMAT planların nitelik güvenirliği sistemlerinin ölçüm sonuçları Sample Paired T testi ve korelasyon testi ile karşılaştırıldığında ArcCheck ve EPID cihazları birbirinin yerine kullanılabilinir.
Özet (Çeviri)
Purpose: To compare various dose verification systems used in Volumetric Modulated Arc Therapy (VMAT) in terms of their reliability and applicability with treatment planning system (TPS) on dosimetric aspects. Material and Methods: In this study, the accuracy of VMAT plans, which were prepared by using Eclipse (Varian Medical Systems) TPS, were compared with different (various) dose verification systems for a total of thirty one locally advanced head and neck cancer patiens before their treatment. The VMAT plans were checked with ArcCheck (Sun Nuclear) diode detectors, EPID (Varian Medical Systems) and EPIQA quality assurance (QA) systems using gamma analysis method. The QA plans for each patient were created by placing the gantry, collimator and table angles in the appropriate positions in the Eclips TPS for all QA systems. The plans for each QA systems were irradiated with TrueBeam. Dose maps were obtained with irradiation. Dose difference was 3%, whereas distance to agreement was 3 mm selected for comparison QA systems. Statistical analyzes were performed using SPSS Version 24 program Correlation analysis and Sample Paired T-test. Results: The average results of ArcCheck, EPID and EPIQA using gamma analysis method compared with TPS was observed as %98,41 (94,9-100) (±1,700), %99,70 (98,6-100) (±0,329), %96,78 (86,7-99,32) (±2,893) , respectively. According to gamma analysis results, two of the measurements made with ArcCheck and EPIQA did not pass acceptance limit (%95), but ArcCheck's measurement results too close to acceptance limit (%95). Besides this, all of the measurements made with EPID are above the 95% acceptance limit. The r values obtained by Correlation analysis were 0,506 for compared ArcCheck and EPID, 0,132 for compared EPID and EPIQA, 0,203 for compared ArcCheck and EPIQA. Conclusion: ArcCheck and EPID devices can be used interchangeably when comparing the measurement results of the qualitative reliability systems of the VMAT plans in the local advanced head and neck cancer with the Sample Paired T test and the Correlation test.
Benzer Tezler
- Baş-boyun kanserlerinde yoğunluk ayarlı radyoterapi (YART)ve hacimsel ayarlı ark terapi (VMAT) tekniklerinin hastayaözel tedavi kalite güvencelerinin karşılaştırılması
Comparison of intensity modulated radiationtherapy and volumetric modulated arc therapy methods of quality assuarence in head and neck cancers
ABDURRAHMAN İSMAİL KORKMAZ
Yüksek Lisans
Türkçe
2015
Radyasyon OnkolojisiUludağ ÜniversitesiRadyasyon Onkolojisi Ana Bilim Dalı
DOÇ. DR. CANDAN DEMİRÖZ ABAKAY
- Baş boyun kanserlerinde uygulanan radyoterapinin koku fonksiyonu üzerine etkilerinin deneysel olarak araştırılması
Experimental research of the effects of radiotherapy on olfaction in head and neck cancers
SAFİYE SENGÜL ÇİVİCİ
Tıpta Uzmanlık
Türkçe
2007
Kulak Burun ve BoğazOndokuz Mayıs ÜniversitesiKulak Burun Boğaz Hastalıkları Ana Bilim Dalı
PROF.DR. RECEP ÜNAL
- Radyasyon uygulanan dişlerde farklı restoratif materyallerle yapılan restorasyonların mikrosızıntı yönünden incelenmesi
The mıcroleakage evaluatıon of restoratıons whıch done wıth dıfferent restoratıve materıals over the radıatıon applıed teeth
ABDÜL SEMİH ÖZSEVİK
Doktora
Türkçe
2011
Diş HekimliğiOndokuz Mayıs ÜniversitesiDiş Hastalıkları ve Tedavisi Ana Bilim Dalı
DOÇ. ERTAN ERTAŞ
- Radyoterapi görmüş ratlarda pentoksifilinin HIF-1α gen ekspresyonu ve serum HIF-1α düzeyleri üzerine etkisinin araştırılması
Investigation of the effect of pentoxifylline on HIF-1ALPHA gene expression and serum HIF-1α levels in irradiated rats
MERVE DEMİR GÜLEÇ
Doktora
Türkçe
2022
Diş Hekimliğiİstanbul ÜniversitesiAğız Diş ve Çene Cerrahisi Ana Bilim Dalı
DOÇ. DR. KIVANÇ BEKTAŞ KAYHAN
- Baş-boyun radyoterapisi uygulanan hastalarda glutamin kullanımının yaşam kalitesi üzerine etkisi
The effect of glutamin supplements on quality of life in head and neck cancer patients who received radiotherapy
AHMET ÇİNKAYA
Tıpta Uzmanlık
Türkçe
2010
Radyoloji ve Nükleer Tıpİstanbul ÜniversitesiRadyasyon Onkolojisi Ana Bilim Dalı
PROF. DR. SEDAT TURKAN