Kendinden klempli foley sondanın üriner sistem enfeksiyonuna ve hemşire iş yüküne etkisi

The effect of self-clampping foley catheter on the urinary tract infection and work load of nurse

  1. Tez No: 466536
  2. Yazar: DEMET BÜYÜK AKBAŞ
  3. Danışmanlar: YRD. DOÇ. BİLGİ GÜLSEVEN KARABACAK
  4. Tez Türü: Yüksek Lisans
  5. Konular: Hemşirelik, Nursing
  6. Anahtar Kelimeler: Foley Kateter, Klemp, Üriner Sistem Enfeksiyonu, Hemşire, İş Yükü, Hemşireler, Hemşirelik, Hemşirelik araştırmaları, Hemşirelik hizmetleri, Kateterizasyon, Üreter hastalıkları, Üriner sistem, Üriner sistem enfeksiyonları, Foley Catheter, Clamp, Urinary Tract Infection, Nurse, Workload, Nurses, Nursing, Nursing research, Nursing services, Catheterization, Ureteral diseases, Urinary tract, Urinary tract infections
  7. Yıl: 2017
  8. Dil: Türkçe
  9. Üniversite: Marmara Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Hemşirelik Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Amaç: Araştırmacı tarafından tasarlanan kendinden klempli foley sondanın üriner sistem enfeksiyonu ve hemşire iş yüküne etkisini değerlendirmektir. Gereç ve Yöntem: Araştırma randomize kontrollü olarak planlandı ve gerçekleştirildi. Çalışmanın evrenini Ocak–Temmuz 2015 tarihleri arasında İstanbul'da bir devlet hastanesinde Dahili ve Cerrahi birimlerde yatan, araştırmaya dahil edilme kriterlerini karşılayan hastalar ile bu kliniklerde çalışan hemşireler oluşturdu. Örneklem grubunu ise kendinden klempli foley sonda takılan 50 hasta (deney) ve foley sonda takılan 50 hasta (kontrol) olmak üzere toplam 100 hasta ve 67 hemşire oluşturdu. Verilerin toplanmasında 'Hasta Tanılama Formu' ve idrar kültürü sonuçlarından yararlanıldı. Veriler değerlendirilirken tanımlayıcı istatistiksel yöntemler (Frekans, Yüzde, Ortalama) ile verilerin karşılaştırılmasında Ki-Kare ve Mann- Whitney U testleri kullanıldı. Bulgular: Deney ve kontrol grupları arasında tanıtıcı özellikler ve mikroorganizma üreme sonuçları açısından anlamlı fark bulunmadı (p>0,05). Mikroorganizma üreme oranı foley sonda kullanılan hastalarda %30 (n=15) iken kendinden klempli foley sonda kullanılan hastalarda %16 (n=8) bulundu. Sondanın hastada kalış gününe göre bakıldığında, 11-30 günlük zaman diliminde kendinden klempli foley sonda kullanılan hastalarda üreme sayısı daha azdı. Hemşirelerin %89,5'i kendinden klempli foley sondanın iş yükünü azalttığını ve %97'si kullanımını önerdiğini belirtti. Sonuçlar: Kendinden klempli foley sondanın 11-30 gün arası kullanımda üriner sistem enfeksiyonunu ve hemşirenin iş yükünü azaltacağı sonucuna varıldı.

Özet (Çeviri)

Purpose: It was aimed to evaluate the effects of the self-clamping foley catheters designed by the researcher on the urinary tract infection risk and the work load of the nurse. Material and Method: The research was planned and carried out as randomized controlled. The population was formed by the inpatients of the Internal Medicine and Surgery clinics of a public hospital in İstanbul between January and July of 2015 meeting the criteria to participate in the research and the nurses of the same clinics. Sample group was constituted by a total of 100 patients; 50 patients using self-clamping foley catheters (experimental group) and 50 using regular foley catheter (control group); and 67 nurses. Patient Diagnosis Form and ürine culture test results were utilized in the collection of data. Descriptive statistical methods (frequency, percentage, mean) were used in the evaluation and Chi-Square and Mann-Whitey U tests were applied in the comparison of the data. Findings: There were no significant differences in terms of indicative features and microorganism reproduction outcomes between experimental and control groups (p>0.05). While the microorganism reproduction rate was 30% (n=15) in patients with foley catheter, it was 16% (n=8) in those with self-clamping foley catheter. According to the duration of the foley catheter in the patient, the reproduction number was lower in patients using self-clamping foley catheter for 11/30-day period. 89.5% of the nurses stated that the self-clamping foley catheter reduced their workload and 97% stated that they suggest it to be used. Result: In 11-30 days period, it is concluded that using self-clamping foley catheter reduces the patients üriner infection risk and nurses workload .

Benzer Tezler

  1. Kendinden ayarlamaları pid kontrolörünün mikrokontrolör tabanlı gerçeklenmesi

    Implementation of an auto-tuning pid controller based on a microcontroller

    TANER ARSAN

  2. Kendinden ayarlamalı denetleyici tasarımı

    Başlık çevirisi yok

    SEÇKİN ARI

    Yüksek Lisans

    Türkçe

    Türkçe

    1996

    Elektrik ve Elektronik MühendisliğiUludağ Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    YRD. DOÇ. DR. MURAT TÜRE

  3. Kendinden ayarlamalı PID kontrolun saccharomyces cerevisiae üretilen bir biyoreaktöre uygulanması ve optimum kontrol parametrelerinin bulunması

    Application of self-tuning PID control to a bioreactor in which saccharomyces cerevisiae is produced and determination of optimal control parameters

    ARZU KAHVECİOĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    1999

    Kimya MühendisliğiAnkara Üniversitesi

    Kimya Mühendisliği Ana Bilim Dalı

    PROF. DR. MUSTAFA ALPBAZ

  4. Kendinden uyartımlı asenkron jeneratörün geçici ve sürekli durum davranışının modellenmesi

    Modelling of steady and transient state behaviour of self-excited asynchronous generator

    SENCER ÜNAL

    Yüksek Lisans

    Türkçe

    Türkçe

    2002

    Elektrik ve Elektronik MühendisliğiFırat Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    DOÇ.DR. YAKUP DEMİR

  5. Kendinden ayarlamalı sayısal PID tasarımı

    Self tuning PID design

    İRFAN YAZICI

    Yüksek Lisans

    Türkçe

    Türkçe

    2002

    Elektrik ve Elektronik MühendisliğiSakarya Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    YRD. DOÇ. DR. AYHAN ÖZDEMİR