Kendinden klempli foley sondanın üriner sistem enfeksiyonuna ve hemşire iş yüküne etkisi
The effect of self-clampping foley catheter on the urinary tract infection and work load of nurse
- Tez No: 466536
- Danışmanlar: YRD. DOÇ. BİLGİ GÜLSEVEN KARABACAK
- Tez Türü: Yüksek Lisans
- Konular: Hemşirelik, Nursing
- Anahtar Kelimeler: Foley Kateter, Klemp, Üriner Sistem Enfeksiyonu, Hemşire, İş Yükü, Foley Catheter, Clamp, Urinary Tract Infection, Nurse, Workload
- Yıl: 2017
- Dil: Türkçe
- Üniversite: Marmara Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Hemşirelik Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: 90
Özet
Amaç: Araştırmacı tarafından tasarlanan kendinden klempli foley sondanın üriner sistem enfeksiyonu ve hemşire iş yüküne etkisini değerlendirmektir. Gereç ve Yöntem: Araştırma randomize kontrollü olarak planlandı ve gerçekleştirildi. Çalışmanın evrenini Ocak–Temmuz 2015 tarihleri arasında İstanbul'da bir devlet hastanesinde Dahili ve Cerrahi birimlerde yatan, araştırmaya dahil edilme kriterlerini karşılayan hastalar ile bu kliniklerde çalışan hemşireler oluşturdu. Örneklem grubunu ise kendinden klempli foley sonda takılan 50 hasta (deney) ve foley sonda takılan 50 hasta (kontrol) olmak üzere toplam 100 hasta ve 67 hemşire oluşturdu. Verilerin toplanmasında 'Hasta Tanılama Formu' ve idrar kültürü sonuçlarından yararlanıldı. Veriler değerlendirilirken tanımlayıcı istatistiksel yöntemler (Frekans, Yüzde, Ortalama) ile verilerin karşılaştırılmasında Ki-Kare ve Mann- Whitney U testleri kullanıldı. Bulgular: Deney ve kontrol grupları arasında tanıtıcı özellikler ve mikroorganizma üreme sonuçları açısından anlamlı fark bulunmadı (p>0,05). Mikroorganizma üreme oranı foley sonda kullanılan hastalarda %30 (n=15) iken kendinden klempli foley sonda kullanılan hastalarda %16 (n=8) bulundu. Sondanın hastada kalış gününe göre bakıldığında, 11-30 günlük zaman diliminde kendinden klempli foley sonda kullanılan hastalarda üreme sayısı daha azdı. Hemşirelerin %89,5'i kendinden klempli foley sondanın iş yükünü azalttığını ve %97'si kullanımını önerdiğini belirtti. Sonuçlar: Kendinden klempli foley sondanın 11-30 gün arası kullanımda üriner sistem enfeksiyonunu ve hemşirenin iş yükünü azaltacağı sonucuna varıldı.
Özet (Çeviri)
Purpose: It was aimed to evaluate the effects of the self-clamping foley catheters designed by the researcher on the urinary tract infection risk and the work load of the nurse. Material and Method: The research was planned and carried out as randomized controlled. The population was formed by the inpatients of the Internal Medicine and Surgery clinics of a public hospital in İstanbul between January and July of 2015 meeting the criteria to participate in the research and the nurses of the same clinics. Sample group was constituted by a total of 100 patients; 50 patients using self-clamping foley catheters (experimental group) and 50 using regular foley catheter (control group); and 67 nurses. Patient Diagnosis Form and ürine culture test results were utilized in the collection of data. Descriptive statistical methods (frequency, percentage, mean) were used in the evaluation and Chi-Square and Mann-Whitey U tests were applied in the comparison of the data. Findings: There were no significant differences in terms of indicative features and microorganism reproduction outcomes between experimental and control groups (p>0.05). While the microorganism reproduction rate was 30% (n=15) in patients with foley catheter, it was 16% (n=8) in those with self-clamping foley catheter. According to the duration of the foley catheter in the patient, the reproduction number was lower in patients using self-clamping foley catheter for 11/30-day period. 89.5% of the nurses stated that the self-clamping foley catheter reduced their workload and 97% stated that they suggest it to be used. Result: In 11-30 days period, it is concluded that using self-clamping foley catheter reduces the patients üriner infection risk and nurses workload .
Benzer Tezler
- Self-tuning PID control with experimental applications
Kendinden-ayarlamali PID kontrol ve deneysel uygulamalari
SALİH SERHAN YURDAKUL
Yüksek Lisans
İngilizce
2009
Elektrik ve Elektronik MühendisliğiÇukurova ÜniversitesiElektrik ve Elektronik Mühendisliği Bölümü
DOÇ. DR. İLYAS EKER
- Yarı kesikli polimer reaktörlerinin modele dayalı kontrolü
Model based control of semi batch polymerization reactors
ÖZLEM GEZMİŞ
Yüksek Lisans
Türkçe
2009
Makine MühendisliğiGazi ÜniversitesiKimya Mühendisliği Bölümü
PROF. DR. SEBAHAT ERDOĞAN
- Kendinden uyartımlı asenkron jeneratörün kondansatör anahtarlamalı gerilim regülasyonu
Voltage regulation of self-excited induction generator by using switching capacitor
ERSİN SELÇUK
Yüksek Lisans
Türkçe
2019
Elektrik ve Elektronik MühendisliğiKonya Teknik ÜniversitesiElektrik-Elektronik Mühendisliği Ana Bilim Dalı
DOÇ. DR. HAYRİ ARABACI
- A computational insight on self-etching and bistyrenic monomers
Kendinden asitli ve stirenik bifonksiyonel monomerlere hesapsal yaklaşım
GÜL BESTE ÖZAYDIN
Yüksek Lisans
Türkçe
2019
KimyaBoğaziçi ÜniversitesiKimya Ana Bilim Dalı
PROF. DUYGU AVCI SEMİZ
PROF. VİKTORYA AVİYENTE
- Constant voltage, constant frequency operation of a self-excited induction generator
Kendinden uyartımlı asenkron generatörün sabit gerilim, sabit frekans altında çalışması
AHMET ÇALIŞKAN
Yüksek Lisans
İngilizce
2005
Elektrik ve Elektronik MühendisliğiOrta Doğu Teknik ÜniversitesiElektrik ve Elektronik Mühendisliği Bölümü
PROF.DR. YILDIRIM ÜÇTUĞ