Lazerle biçimlendirilmiş (laser-structured) tabanı olan seramik braketlerin debonding özelliklerinin incelenmesi
The evaluation of the debonding properties of ceramic brackets with a laser-structured base
- Tez No: 478084
- Danışmanlar: DOÇ. DR. SELMA ELEKDAĞ TÜRK
- Tez Türü: Diş Hekimliği Uzmanlık
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Seramik Braket, Debonding, Adeziv Artık İndeksi, Ağrı, Dental bonding, Diş hekimliği, Lazerler, Ortodonti, Ortodontik braketler, Ceramic Bracket, Debonding, Adhesive Remnant Index, Pain, Dental bonding, Dentistry, Lasers, Orthodontics, Orthodontic brackets
- Yıl: 2017
- Dil: Türkçe
- Üniversite: Ondokuz Mayıs Üniversitesi
- Enstitü: Diş Hekimliği Fakültesi
- Ana Bilim Dalı: Ortodonti Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Amaç: Bu çalışmanın amacı lazerle biçimlendirilmiş (laser-structured) tabanı olan seramik braketlerin iki farklı söküm aletiyle“debond”işlemi sonrasında Adeziv Artık Skorunun (ARI) ve debonding sırasında oluşan ağrının incelenmesi ve karşılaştırılmasıdır. Materyal ve Metot: Yaşları 12 ile 24 arasında değişen (yaş ortalaması 18 yıl 3 ay) 25 kadın ve 7 erkek toplam 32 hasta çalışmaya dahil edildi. Hastaların ortalama tedavi süresi 10,9 ay idi. Çalışmamızda; 640 adet 0,022 inç MBT Discovery Pearl (Dentaurum, Ispringen, Almanya) seramik braket kullanıldı. Tedavi sonunda“debond”işlemi Sushi söküm pensi (American Orthodontics, Sheboygan, USA) ve Discovery Pearl söküm aleti (Dentaurum, Ispringen, Almanya) ile“split-mouth”dizayn ile gerçekleştirildi. Braketlerin söküm işlemi sırasında ARI skorları değerlendirildi. Söküm sırasında oluşan ağrı Vizüel Analog Skalası (VAS) ile değerlendirildi. ARI skoru ve VAS değerleri söküm aletlerine göre karşılaştırıldı. ARI skorlarının karşılaştırılmasında ki-kare (P<0,05) ve VAS değerlerinin karşılaştırılmasında ise Wilcoxon (P<0,05) testleri kullanıldı. Bulgular: ARI skoru; her iki söküm aletinde de benzer dağılım gösterdi. ARI skorları ve VAS değerleri, söküm aletine göre istatistiksel olarak önemli farklılık göstermedi. Sonuç: Discovery Pearl seramik braketlerin sökümü için kullanılan iki farklı söküm aleti artık adeziv miktarı ve ağrı değerinde fark meydana getirmedi.
Özet (Çeviri)
Aim: The aim of this study was to evaluate and compare the clinical success, i.e. Adhesive Remnant Index (ARI) and pain, of two ceramic bracket debonding instruments of ceramic brackets with a laser-structured base. Materials and Methods: Thirty-two patients (25 females and 7 males) aged between 12 and 24 years (mean age 18 years 3 months) were included in this study. The mean duration of treatment was 10.9 months. 640 Discovery Pearl ceramic brackets (Dentaurum, Ispringen, Germany; 0.022- inch MBT system) were used. At the end of the treatment, debonding was performed with a Sushi Debonding Plier (American Orthodontics, Sheboygan, USA) and a Discovery Pearl Debonding Instrument (Dentaurum, Ispringen, Germany) with a split-mouth design. The ARI scores of the patients who completed treatment were determined. Pain/discomfort was assessed with the Visual Analogue Scale (VAS) during the debonding procedure. The ARI scores and the VAS values were determined with respect to the debonding instrument type. The ARI data was examined with ki-kare test (P<0,05), whereas the VAS data was evaluated with the Wilcoxon test (P<0,05). Results: The ARI scores were similar for both debonding instruments. The ARI scores and VAS values did not show a statistically significant difference for both debonding instruments. Conclusion: This clinical trial showed that the two different debonding instruments did not produce any differences concerning the amount of adhesive remnant and pain.
Benzer Tezler
- Lazerle oluşturulan kalay plazma ortamlarından yayılan x-ışınları ve EUV-ışınlarının modellemesi
Modelling of x-rays and EUV-rays emitted from laser produced tin plasmas
BETÜL ATALAY
Doktora
Türkçe
2007
Fizik ve Fizik MühendisliğiÇanakkale Onsekiz Mart ÜniversitesiFizik Ana Bilim Dalı
PROF.DR. ARİF DEMİR
PROF.DR. RAMAZAN AYDIN
- Lazerle oluşturulan plazma ortamlarının hidrodinamik modellenmesi
Hydrodynamic modelling of laser produced plasma media
PINAR DEMİR
Yüksek Lisans
Türkçe
2006
Fizik ve Fizik MühendisliğiKocaeli ÜniversitesiFizik Ana Bilim Dalı
Y.DOÇ.DR. ELİF KAÇAR
- Lazerle delmede işleme parametrelerinin delik kalitesine olan etkisinin deneysel araştırılması
Investigation of the effect of processing parameters for hole quality in laser drilling
ŞENOL ERDOĞAN
Yüksek Lisans
Türkçe
2007
Makine MühendisliğiGazi ÜniversitesiMakine Mühendisliği Ana Bilim Dalı
PROF. DR. BEDRİ TUÇ
- Lazerle kesme işleminde kesme parametrelerinin kesme aralığı ve yüzey kalitesi üzerindeki etkilerinin incelenmesi
Investigation of the effect of cutting parameters on the kerf width and surface quality during the laser cutting process
UFUK ÖNER
Yüksek Lisans
Türkçe
2008
Makine MühendisliğiGazi ÜniversitesiMakine Mühendisliği Bölümü
DOÇ. DR. ÖMER KELEŞ
- Karbon-fiber takviyeli kompozitler ve polikarbonat malzemelerin lazerle delme parametrelerinin belirlenmesi
Carbon-fibre reinforced compozites and determination of laser parameters for holes on polycarbonate materials
LEVENT CANDAN
Yüksek Lisans
Türkçe
2008
Fizik ve Fizik MühendisliğiKocaeli ÜniversitesiFizik Bölümü
YRD. DOÇ. DR. TİMUR CANEL