Nazofarenks kanser hastaları üzerinde yapılan vmat ve rapidarc planlarının dozimetrik parametrelerinin karşılaştırılması

Dosimetric comparison of vmat and rapidarc for nasopharyngeal carcinoma

  1. Tez No: 487125
  2. Yazar: ÖZCAN ÖZDEN
  3. Danışmanlar: DOÇ. DR. CANDAN DEMİRÖZ ABAKAY
  4. Tez Türü: Yüksek Lisans
  5. Konular: Fizik ve Fizik Mühendisliği, Physics and Physics Engineering
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2017
  8. Dil: Türkçe
  9. Üniversite: Uludağ Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Radyasyon Onkolojisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 96

Özet

Bu çalışmada amacı, nazofarenks kanserleri için farklı iki Volumetrik Ayarlı Ark Terapi (VMAT) tekniğini karşılaştırarak hedef hacim, konformite numarası (CI), homojenite numarası (HI), riskli organlar ve Monitor değeri (MU) açısından değerlendirmektir. 20 adet geç evre nazofarenks kanserli hastaya ait Bilgisayarlı Tomografi görüntüleri üzerinde hedef hacim ve kritik organların yerleri konturlanmıştır. Tedavi planları Elekta Synergy lineer akseleratörünü kullanan Monaco TPS'inde ve Varian Trilogy lineer akseleratörünü kullanan Eclipse TPS'inde çift ark (karşılıklı çakışık) olacak şekilde, arklara sırasıyla 30-330 derece kolimatör açısı ayarlanarak tedavi planları hazırlanmıştır. Hedef hacim eşzamanlı entegre boost (SIB) tekniği ile 33 fraksyondan (fx) dan hesaplanmış ve bulunan sonuçlar karşılaştırılmıştır. Bu çalışmada, Elekta için yapılan volumetrik ayarlı ark terapi tekniği“Elekta VMAT”ve Varian için yapılan ise“RapidArc”olarak adlandırılmıştır. Yapılan tüm tedavi planları klinik açıdan kabul edilebilir durumda olsa da hedef hacmin istenilen dozu alması açısından Elekta VMAT, RapidArc tekniği üzerinde başarı göstermiştir. Her iki TPS'de de yapılan planlarda riskli organ dozları kabul edilebilecek sınırda olması rağmen Elekta VMAT tekniğinde beyin sapı, medulla spinalis gibi çok riskli organların dozlarını kanserin tekrarlaması veya ikincil kanserlerden dolayı hastanın tekrar ışın alması durumuna karşı istenilen değerlerden biraz daha düşük tutmayı başarmıştır. Ayrıca CI ve HI değerleri açısından Elekta VMAT üstünlük göstermiştir. Fakat hastanın lens, optik sinir dozlarında ve MU değerinde RapidArc tekniği daha başarılı sonuçlar vermiştir. Sonuç olarak her iki teknikte de yapılan tedavi planları arasında istatistiksel olarak anlamlı farklılıklar olsa da değerler kabul edilebilecek sınırlardadır. Hastanın durumuna göre iki teknikten birisi seçilebilir.

Özet (Çeviri)

The aim of this study is to evaluate target volume, conformity index (CI), homogeneity index (HI), risky organs and monitor unit (MU) by comparing two different Volumetric Modulated Arc Therapy (VMAT) techniques for nasopharyngeal cancers. Computer tomography images of 20 patients with advanced stage nasopharyngeal carcinoma were contoured on target volumes and locations of critical organs. Treatment plans were prepared for Elekta Synergy lineer accelerator which using Monaco TPS and Varian Trilogy lineer accelerator which using Eclipse TPS and treatment plans were prepared double arc (mutually overlapping) and collimator angles for each arc is 30-330 degrees. The target volume was calculated from 33 fractions (fx) by the simultaneous integrated boost (SIB) technique and the results were compared. In this study, volumetric arc therapy technique for Elekta was named“Elekta VMAT”and for Varian it was named“RapidArc”. Although both tecniques are clinically acceptable, Elekta VMAT has succeeded in RapidArc technique in terms of wanted target dose. Elekta VMAT technique has kept the doses a little lower on critical organs such as brain stem, medulla spinalis than the wanted values for recurrence of the cancer or re-irradiation of the patient due to secondary cancers, although the risky organ doses can be accepted in both TPS plans. In addition, Elekta VMAT was superior in terms of CI and HI values. However, with the patient's lens, optic nerve doses and monıtor unit, the RapidArc technique yielded more successful results. As a result, although there are statistically significant differences between the treatment plans made in both techniques, the values are the acceptable limits. Depending on the condition of the patient one of the two techniques can be selected.

Benzer Tezler

  1. Nazofarenks karsinomlarında P53 ekspresyonu

    Başlık çevirisi yok

    FULYA YAMAN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1997

    Radyoloji ve Nükleer Tıpİstanbul Üniversitesi

    Radyasyon Onkolojisi Ana Bilim Dalı

  2. Baş-boyun kanserli hastalarda tedavi öncesi ve sonrası serum immünoglobülin-A,M ve G değerleri

    Başlık çevirisi yok

    YAVUZ UYAR

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1984

    Kulak Burun ve BoğazAnkara Üniversitesi

    Kulak Burun Boğaz Ana Bilim Dalı

    PROF.DR. NİMETULLAH ESMER

  3. Nazofarinks kanserli hastalarda tedavi sonuçlarımızın değerlendirilmesi ,eski ve yeni evre şemasının karşılaştırılması

    Results of patients with Nasopharyngeal carcinoma treated in Hacettepe University

    HAMED FARAJOLLAHİ FAR

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2012

    OnkolojiHacettepe Üniversitesi

    Radyasyon Onkolojisi Ana Bilim Dalı

    PROF. DR. MUSTAFA CENGİZ

  4. Kolorektal karsinoma'lı hastalarda real-tıme polimeraz zincir reaksiyonu (real-time PCR) yöntemi ile human papillomavirus Tip 16 pozitifliğinin gösterilmesi

    Başlık çevirisi yok

    AYÇA ÖZER DURMUŞLU

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2014

    MikrobiyolojiGazi Üniversitesi

    Tıbbi Mikrobiyoloji Ana Bilim Dalı

    DOÇ. DR. GÜLENDAM BOZDAYI

  5. 2007-2010 yılları arasında kliniğimizde tedavi edilen baş ve boyun kanserli hastaların retrospektif değerlendirilmesi

    Retrospective evaluation of patients with head and neck cancer treated in our clinic between 2007 and 2010

    EBRU ATASEVER AKKAŞ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2011

    OnkolojiCumhuriyet Üniversitesi

    Radyasyon Onkolojisi Ana Bilim Dalı

    YRD. DOÇ. DR. BİRSEN YÜCEL