Standart bir odanın radyant soğutulması durumunda havalandırmanın konfora etkisinin incelenmesi

Determining the effect of the ventilation system on thermal comfort in a standard room with radiant cooling system

  1. Tez No: 488179
  2. Yazar: ONUR ORUÇ
  3. Danışmanlar: PROF. DR. İSMAİL TEKE
  4. Tez Türü: Yüksek Lisans
  5. Konular: Enerji, Makine Mühendisliği, Mühendislik Bilimleri, Energy, Mechanical Engineering, Engineering Sciences
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2017
  8. Dil: Türkçe
  9. Üniversite: Yıldız Teknik Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Makine Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Isı Proses Bilim Dalı
  13. Sayfa Sayısı: 108

Özet

Isıl konfor basit olarak insan ile ortam arasındaki enerji dengesine dayanmaktadır. İnsan vücudu sıcak bir ortamda bulunduğu sırada ısı kaybetmek için terleme durumuna, soğuk ortamda bulunduğu sırada ise ısınmak için titreme durumuna geçer. Bu nedenle günlük hayatta ısıl konfor insanların yaşam kalitesini oldukça etkilemektedir. Isıl konfor hesaplama metodu Fanger'in 1970 yılında geliştirmiş olduğu PMV-PPD yöntemine dayanmaktadır. Radyant panel sistemleri kullanılarak yapılan ısıtma ve soğutma diğer konvensiyonel sistemler kullanılarak yapılan ısıtma ve soğutmaya göre daha iyi ısıl konfor değerleri sunmaktadır. Taze hava ihtiyacı sağlamak ve odadaki hava kalitesini artırmak için ise havalandırma sistemleri radyant panel sistemleriyle birlikte kullanılmaktadır. Bu çalışmada, tüm bu durumlar göz önüne alınarak radyant panel kullanılarak yapılan soğutma durumunda havalandırmanın ısıl konfora etkisinin incelenmesi amaçlanmıştır. Bu amaçla zemin alanı 24 m2 (6.00 m x 4.00 m) ve yüksekliği 3.00 m olan, iki yüzü dış duvar, iki yüzü iç duvar olarak kabul edilmiş standart bir oda modeli tasarlanmıştır. Tasarlanan bu model üzerinde pasif havalandırmasız sadece radyant panel sistemi kullanılarak soğutma ve farklı havalandırma durumlarıyla desteklenen radyant panel sistemli soğutma durumları ANSYS – Fluent yazılımı kullanılarak analiz edilmiştir. Isı perdeli havalandırma sistemi kullanılarak yapılan soğutma, pencereden gelen ısı geçişini engellemiş, paneller vasıtasıyla çekilmesi gereken ısı oranını azaltmıştır. Panellere tanımlanan ısı akısının -16 W/m2 olduğu ısı perdeli havalandırma durumu, tavandan havalandırmalı -14 W/m2 ısı akılı durum, havalandırmasız -18 W/m2 ısı akılı olan durum ve yine havalandırmasız -22 W/m2 ısı akılı olan durum ASHRAE 55 ve ISO 7730 standartlarına göre konforsuz bulunmuşlardır. En iyi ısıl konfora sahip durumlar, ısıl perdeli havalandırmalı soğutma durumunda panellere tanımlanan -18 W/m2 ısı akılı ve -20 W/m2 ısı akılı olan durumlardır.

Özet (Çeviri)

Basically, thermal comfort is based on energy balance between human body and an environment. Human body sweats when the environment is too hot. On the contrary case, human body shivers when the environment is too cold. For this reason, thermal comfort effects the quality of life in daily life. The calculation method of thermal comfort is based on PMV-PPD approach which was developed by Fanger in 1970. In heating and cooling conditions, radiant panel systems provide better thermal comfort than conventional systems. Ventilation systems are used with radiant panel systems to improve Indoor Air Quality and provide fresh air need. In this study, determining the effect of the ventilation system on thermal comfort with radiant cooling system is aimed. For this purpose, a standard room was designed whose floor area is 24 m2 and heigh 3.00 m. It has two interiors and two exterior walls. For this standard room, only radiant panel system without ventilation and radiant panel system which support by different ventilation types are analyzed with ANSYS - Fluent software. Ceiling ventilation which is located next to the window creates thermal protection curtain. Thus the ventilation system blocks the heat transfer from the window in to the room. Ceiling ventilation which is located next to the window with -16 W/m2 heat flux, mixing ventilation with -14 W/m2 heat flux, passive cooling with -18 W/m2 heat flux and -22 W/m2 heat flux were not found thermally comfortable according to the ASHRAE 55 and ISO 7730 standards. Ceiling ventilation which is located next to the window with 18 W/m2 heat flux and -20 W/m2 heat flux have the best thermal comfort values rather than others according to the ASHRAE 55 and ISO 7730 standards.

Benzer Tezler

  1. Investigation of thermal comfort performance of radiant heating systems: Comparisons of different heating surface configurations

    Radyant ısıtma sistemlerinin termal konfor performansının incelenmesi: Farklı ısıtma yüzey konfigürasyonlarının karşılaştırılması

    RUŞEN CAN ACET

    Yüksek Lisans

    İngilizce

    İngilizce

    2018

    Makine MühendisliğiÖzyeğin Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    PROF. DR. MUSTAFA PINAR MENGÜÇ

  2. Toprak kaynaklı ısı pompalı radyant ısıtma/soğutma sistemlerinde ısıl konforun deneysel incelenmesi

    Experimental investigation of thermal comfort in radiant heating-cooling systems coupled with ground source heat pump

    AHMET DOĞAN

    Doktora

    Türkçe

    Türkçe

    2023

    EnerjiYıldız Teknik Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    PROF. DR. HAKAN DEMİR

    DR. ÖĞR. ÜYESİ NURULLAH KAYACI

  3. COVİD-19 hastalarında toraks içi oluşumların morfometrik özelliklerinin mortalite üzerine etkisinin incelenmesi

    Investigation of morphometric properties of intrathoracic structures on mortality in COVID-19 patients

    ALİ YAVUZ UZUN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2022

    AnatomiRecep Tayyip Erdoğan Üniversitesi

    Anatomi Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ YILMAZ ÜÇÜNCÜ

    DR. ÖĞR. ÜYESİ NUR HÜRSOY

  4. Design and control of an autonomous blimp

    Otonom hava aracı (Zeplin) tasarımı ve kontrolü

    ERTUĞRUL BAYRAKTAR

    Yüksek Lisans

    İngilizce

    İngilizce

    2013

    Elektrik ve Elektronik Mühendisliğiİstanbul Teknik Üniversitesi

    Mekatronik Mühendisliği Ana Bilim Dalı

    YRD. DOÇ. DR. PINAR BOYRAZ