Geri Dön

Spinal enstrumantasyon yapılan hastalarda titanyum kaplı implantların titanyum salınımının değerlendirilmesi

Evaluation of titanium release from titanium alloy implants in patients underwent spinal instrumentation surgery

  1. Tez No: 493363
  2. Yazar: ARMAĞAN CAN ULUSALOĞLU
  3. Danışmanlar: DOÇ. DR. TEOMAN ATICI
  4. Tez Türü: Tıpta Uzmanlık
  5. Konular: Ortopedi ve Travmatoloji, Orthopedics and Traumatology
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2018
  8. Dil: Türkçe
  9. Üniversite: Uludağ Üniversitesi
  10. Enstitü: Tıp Fakültesi
  11. Ana Bilim Dalı: Ortopedi ve Travmatoloji Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 43

Özet

Posterior enstrumantasyon uygulaması Harrington implantlarla başlayıp günümüzde modern implant malzemeleri olan pedikül vidası,kanca (hook), rod ve ara bağlantı kullanılarak devam etmektedir. 20. yüzyılın başında spinal füzyonu oluşmasını sağlamak amacıyla otogreft kemik dokulardan yararlanılsa da, 1990 ve sonrasında pedikül vidası ve kanca kullanımı ile daha az morbidite oluşması sağlanmıştır. Çalışmamızda spinal füzyon sağlanmış hastalarda titanyum kaplı implantların kandaki titanyum değerleri ölçülerek spinal füzyon ve titanyum değeri arasında bir korelasyon sağlanması amaçlanmıştır. Uludağ Üniversitesi Sağlık Uygulama ve Araştırma Hastanesi'nde Ocak 2013 ve Haziran 2016 tarihleri arasında, 5 seviye ve altı radyolojik spinal füzyon sağlanmış, spinal enstrumantasyon uygulanan hastalar çalışmaya dahil edilmiştir. Spinal stenoz, spondilolistezis ve vertebra fraktürü olan hastalar değerlendirildi. Daha önceden implant cerrahisi geçirmemiş kişiler seçilerek kontrol grubu oluşturuldu. 39 (%78) hasta (Grup I) ve 11 (%22) (Grup II) kontrol grubu toplamda 50 kişilik kesitsel bir grup oluşturuldu. Grup I'de hastaların 21'i (%42) erkek, 18'i (%36) bayandı. Grup II'de ise 7 (%14) kişi erkek, 4 (%8) kişi ise bayandı. Grup I'de ortalama yaş 53.8 , Grup II'de ortalama yaş ise 59.2 olarak saptandı. Her iki grup yaş ortalaması karşılaştırıldığında anlamlı fark tespit edilmedi (p=0.089). Titanyum değerleri Grup I ve Grup II'de sırasıyla ortalama 0,0480,009 (0,023-0,067) µg/L ve 0,0200,000 (0,000-0,020) µg/L idi. Grup I'de titanium salınım değeri Grup II ile karşılaştırıldığında anlamlı fark tespit edildi (p

Özet (Çeviri)

Evaluation of the titanium release of the titanium coated implants with the patients who were operated spinal instrumentation. The posterior instrumentation, which strated formerly with Harrington implants, continues today with the use of pedicule screw rod and interconnect joint. At the beginning of the 20th Century, even though autogreft bone tissues were utilized in order to provide the formation of spinal fusion; in 1990's and after then; with the use of pedicul screw and hook; less morbidity cases were ensured. In our study; the titanium values of the patients, who were supplied spinal fusion, were measured and it was targeted to provide a correlation between the spinal fusion and the titanium value. At the Uludağ University College of Medicine, patients had been examined spinal instrumentation for the spinal fusion less than five levels between January 2013 and January 2016 were involved in this study. The patients were diagnosed with spinal stenosis, spondylolisthesis and vertebrae fracture were evaluated. A control group was created by choosing people who had not undergone implant surgery previously. A study group of totally 50 people, that including 39 (78%) patients (Group I) and 11 (22%) people (Group II) formed as the study group and control group consecutively.In Group I 21 (42%) men and 18 (36%) women of the patients who were involved. In Group II 7 (14%) men and 4 (8%) women were chosen. In Group I the average age was 53.8 and in Group II average age was 59.2. When the average ages of two groups were compared; no significantly difference was detected (p=0.089). Titanium values were 0.0480.009 (0.023-0.067) μg/L and 0.0200.000 (0.000-0.020) μg/L respectively in Group I and Group II. The value of titanium release in Group I was significantly different from Group II (p

Benzer Tezler

  1. Dinamik ve rijit posterior lomber spinal enstrümantasyon cerrahisinde interbody füzyon kombinasyonu yapılan ve yapılmayan olgularının radyolojik ve klinik sonuçlarının karşılaştırılması

    Comparison of radiological and clinical results of cases with and without interbody fusion combination in dynamic and rigid posterior lombar spinal instrumentation surgery

    EMİR DARCAN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2021

    NöroşirürjiSağlık Bilimleri Üniversitesi

    Beyin ve Sinir Cerrahisi Ana Bilim Dalı

    PROF. DR. ALİ ENDER OFLUOĞLU

  2. Dejeneratif lomber dar kanalda yapılan dinamik ve rijit enstrümantasyonun klinik-radyolojik sonuçlarının karşılaştırılması

    Başlık çevirisi yok

    EYÜP VAROL

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2019

    NöroşirürjiSağlık Bilimleri Üniversitesi

    Beyin ve Sinir Cerrahisi Ana Bilim Dalı

    DOÇ. DR. MEHMET REŞİD ÖNEN

  3. Konjenital skolyozda posterior enstrumantasyonun yeri ve önemi

    The role and importance of posterior instrumentation in congenital scoliosis

    TOLGA EGE

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2008

    Ortopedi ve TravmatolojiGATA

    Ortopedi ve Travmatoloji Ana Bilim Dalı

    PROF. DR. ALİ ŞEHİRLİOĞLU

  4. Scheuermann kifozunda posterior enstrümantasyon ve füzyon sonrası proksimal ve distal bileşke kifozunun değerlendirilmesi

    Evaluation of the proximal and distal junctional kiphosis after posterior instrumentation and fusion in scheuermann kiphosis

    MURAT BAKIR

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2021

    Ortopedi ve TravmatolojiSağlık Bilimleri Üniversitesi

    Ortopedi ve Travmatoloji Ana Bilim Dalı

    DOÇ. DR. HAKAN SERHAT YANIK

  5. Torakolomber vertebra kırıklarının posterior spinal enstrumantasyon sistemleri ile tedavisi (Klinik çalışma)

    The Treatment of thoracolumbar spine fractures with posterior spinal instrumentations (Clinical study)

    DİNÇAY ULUÇ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1998

    Ortopedi ve TravmatolojiDicle Üniversitesi

    Ortopedi ve Travmatoloji Ana Bilim Dalı

    DOÇ. DR. SERDAR NECMİOĞLU