Geri Dön

Primer kullanılan ve kullanılmayan farklı kompozit materyalleri ile yapıştırılan ortodontik braketlerin dayanımlarının in vitro olarak incelenmesi

Investigation of the in vitro shear bond strength of orthodontic brackets bonded with composites with or without the use of a primer

  1. Tez No: 499239
  2. Yazar: GÜL AYDIN ŞANLITÜRK
  3. Danışmanlar: YRD. DOÇ. AYŞE BURCU ALTAN, PROF. DR. ALİ İHYA KARAMAN
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Dental bonding, Dental materyaller, Dental çimentolar, Kompozit reçineler, Ortodonti, Ortodontik braketler, Yapışma performansı, Dental bonding, Dental materials, Dental cements, Composite resins, Orthodontics, Orthodontic brackets, Adhesion performance
  7. Yıl: 2018
  8. Dil: Türkçe
  9. Üniversite: Kocaeli Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Ortodonti Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmanın amacı, primer kullanılan ve kullanılmayan yapıştırma sistemleri ile mine yüzeyine yapıştırılan braketlerin mukavemetlerini karşılaştırmaktır. Bu amaçla elde edilen 100 adet premolar diş, dört gruba ayrılmıştır. Bir gruba konvansiyonel bir braket yapıştırma kompoziti olan Transbond XT kompozit (Transbond XT Adhesive, 3M Unitek, Calif) primeri ile beraber kullanılmış (Transbond XT Primer, 3M Unitek , Calif), ikinci grupta aynı yapıştırma prosedürü primer basamağı çıkartıılarak uygulanmış, diğer iki grupta ise üretici firma talimatları doğrultusunda primer kullanılmadan uygulanmaları tavsiye edilen GC Ortho Connect (GC Orthodontics, Japonya) ve Biofix (Biodinamica, Ibipora, Brezilya) kompozitler kullanılarak metal ortodontik braketler mine yüzeyine yapıştırılmıştır. Braket yapıştırılmış dişler termal siklüs ile yaşlandırıldıktan sonra örneklere sıyırma testi uygulanmış ve bağlanma dayanımları ölçülmüştür. Daha sonra kopmanın meydana geldiği bölgelerin belirlenmesi için stereo mikroskop ile ARI skorlaması yapılmıştır. Primer kullanımı, Transbond XT gruplarının mukavemetleri ve ARI skorları arasında anlamlı farklılık yaratmamıştır. GC Ortho Connect'in mukavemeti primer kullanılan Transbond XT grubu ile benzer bulunmuş, Biofix'in mukavemeti ise primer kullanılan Transbond XT ve GC Ortho Connect gruplarından düşük bulunmuştur. GC Ortho Connect grubunun ARI skorları diğer gruplardan anlamlı olarak farklı bulunmuş, kopmanın bu grupta genelde adezivin kendi yapısı içerisinde gerçekleştiği, diğer gruplarda ise mine-adeziv arayüzünde meydana geldiği görülmüştür. Braket yapıştırma işlemleri esnasında primer uygulama basamağı çıkartıldığında da yeterli mukavemet elde edilebilmektedir. Ancak, primer kullanımı braketlerin söküm aşamasında minede oluşabilecek hasarlara karşı koruyucu olabilir.

Özet (Çeviri)

The purpose of this study is to compare the shear bond strength of adhesive systems with or without the use of primer in bonding orthodontic brackets to enamel. For this purpose, 100 premolar teeth were obtained and seperated into four groups. In one group, Transbond XT Adhesive (3M Unitek, Calif) was used with a primer (Transbond XT Primer, 3M Unitek, Calif), in the second group the same bonding procedure was followed, only the use of the primer was excluded. In the third and fourth groups, two orthodontic adhesives (GC Ortho Connect, GC Orthodontics, Japan; Biofix, Biodinamica, Ibipora, Brazil) that are used without a primer per manufacturers instructions were used to bond metal orthodontic brakets to the enamel surface. The specimens were aged with thermal cycling and then tested for shear bond strength. The failure sites were assessed with the ARI score using a stereo microscope. The use of a primer created no statistically significant difference in shear bond strength or ARI scores using the Transbond XT adhesive. The shear bond strength of GC Ortho Connect was found to be similar to the Transbond XT adhesive group when used with a primer. The shear bond strength regarding Biofix was found to be lower than Transbond XT with the use of a primer and GC Ortho Connect. The failure mode regarding GC Ortho Connect was primarily found to be within the adhesive and this finding was significantly different than the other groups. The failure mode observed in the other groups was mostly at the enamel-adhesive interface. Sufficient shear bond strength is obtainable when primer application is exluded during bonding brackets to teeth. However, the use of a primer may be protective against enamel damage during debonding procedures.

Benzer Tezler

  1. Değişik derim zamanı ve önsoğutmanın Bursa siyahı incir çeşidinin meyve kalitesi ve pazarlama süresi üzerine etkileri

    Effects of haruest time and precooling on fruit quality and shelf-life of the fig variety“Bursa siyahı”

    FÜSUN GÜRSEL ÇELİKEL

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Bahçe Bitkileri Ana Bilim Dalı

    Yükleniyor...

  2. Traditional vernacular houses in Anatolia: The question of evaluative criteria

    Anadolu geleneksel yöresel konut mimarlığında değerlendirme ölçütleri sorunu

    OKAN ÜSTÜNKÖK

    Doktora

    İngilizce

    İngilizce

    1987

    Orta Doğu Teknik Üniversitesi

    Mimarlık Ana Bilim Dalı

    Yükleniyor...

  3. Bazı buğday türlerinde poliploidi düzeyine bağımlı IAA ve ABA miktarlarının kantitatif belirlenmesi üzerine bir araştırma

    Başlık çevirisi yok

    SEVGİ HEPAKSOY

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Botanik Ana Bilim Dalı

    Yükleniyor...

  4. Dirichlet karakterleri ve sınıf sayısı bir olan cyclotomic cisimler

    Başlık çevirisi yok

    NEŞET AYDIN

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    Cumhuriyet Üniversitesi

    Matematik Ana Bilim Dalı

    Yükleniyor...

  5. Tanenlerin çilek organ ve dokularındaki dağılımı ve mevsimsel değişimi üzerine araştırmalar

    Başlık çevirisi yok

    ŞENEL ALBAYRAK

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Ege Üniversitesi

    Bahçe Bitkileri Ana Bilim Dalı

    Yükleniyor...