Geri Dön

Heat tarnsfer in falling film evaporators

Başlık çevirisi mevcut değil.

  1. Tez No: 50802
  2. Yazar: A.MÜJDEM SAÇIAK
  3. Danışmanlar: PROF.DR. FİRUZ BALKAN
  4. Tez Türü: Yüksek Lisans
  5. Konular: Makine Mühendisliği, Mechanical Engineering
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 1996
  8. Dil: İngilizce
  9. Üniversite: Ege Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Belirtilmemiş.
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 56

Özet

Özet yok.

Özet (Çeviri)

Ill SUMMARY The variation of the heat transfer coefficients in a falling film evaporator at which evaporation takes place from the surface of the liquid films flowing down the inside surface of the vertical tube was investigated in this study. The experimental data were compared with the existing heat transfer data in the literature. As test fluids, distilled water and sodium hydroxide solutions at different concentrations (10% and 20%) were used. Test section which has a length of 500 mm. was heated by means of high current transformatör which supplies an alternative current of 275 A. Surface temperatures were measured at 8 different locations by means of“NiCr -Ni ”tliermocouples. hi the experiments performed by water and 10% sodium hydroxide solution the flow regime was turbulent and in experiments performed by 20% sodium hydroxide solution flow regime was laminar. The Reynolds Number ranged from 1 800 to 10 300, PrandÖ Number ranged from 1.76 to 4.625 and the heat flux applied to the tube wall was at the range of 12 255 to 12.690 W/m2. From the results it was seen that the thermal development length persisted up more than one half of the heated length for all the liquids tested, heat transfer coefficients were compared to each other and new correlations were developed. According to this comparison it was determined that for water and 10% sodium hydroxide solution the following correlation was used : h* = 0.003 Re 038Pr092 This is very close to the correlation that was recommended by Mudawwar. For the experiments performed by 20% NaOH which was in laminar regime, developed correlation was close to that was obtained by Chun and Seban and it was found to be, h*= 0.66 (Re/4)-023

Benzer Tezler

  1. Düşey film evaporatörlerde tasarım geometrisinin etkin akış dağılımı üzerine etkilerinin incelenmesi

    Investigation of the effects of design geometry on effective flow distribution in falling film evaporators

    EKİN CAN DOLGUN

    Yüksek Lisans

    Türkçe

    Türkçe

    2021

    EnerjiGazi Üniversitesi

    Enerji Sistemleri Mühendisliği Ana Bilim Dalı

    PROF. DR. MUSTAFA AKTAŞ

  2. Dikey borulu buharlaştırıcılarda düşme yüksekliğinin ısı geçişiyle olan ilişkisinin deneysel araştırılması

    Experimental reseach of relation of falling elavation in vertical tube evaporator with heat transfer

    HÜSEYİN PEHLİVAN

    Doktora

    Türkçe

    Türkçe

    2008

    Mühendislik BilimleriSakarya Üniversitesi

    Makine Mühendisliği Bölümü

    YRD. DOÇ. DR. MUSTAFA ÖZDEMİR

  3. Absorpsiyonlu soğutma sisteminin simülasyonu

    Simulation of absorption cooling system

    ABDULVAHAP YİĞİT

    Doktora

    Türkçe

    Türkçe

    1990

    Makine Mühendisliğiİstanbul Teknik Üniversitesi

    PROF.DR. NİLÜFER EĞRİCAN

  4. Effect of frost formation on heat transfer: Experimental investigation and numerical model development

    Karlanmanın ısı transferi üzerindeki etkisi: Deneysel inceleme ve sayısal model geliştirme

    ALPER SAYGIN

    Yüksek Lisans

    İngilizce

    İngilizce

    2023

    Makine MühendisliğiÖzyeğin Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    DR. ALTUĞ MELİK BAŞOL

    PROF. DR. MEHMET ARIK