Geri Dön

Vakum şekillendirici pekiştirme apareylerinin oklüzal kuvvet parametrelerinin T-scan III ile değerlendirilmesi

Evaluation of occlusal force parameters of vacuum formed retainer with T-scan III

  1. Tez No: 523304
  2. Yazar: DİLRUBA SANYA SADIKZADE
  3. Danışmanlar: PROF. DR. SEHER GÜNDÜZ ARSLAN
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Vakum Ģekillendirici plak, T-Scan III, PekiĢtrime, Oklüzyon, Vacuum formed retainer, T-Scan III, Retenion, Occlusion
  7. Yıl: 2018
  8. Dil: Türkçe
  9. Üniversite: Dicle Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Ortodonti Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 103

Özet

. Bu araştırmanın amacı pekiştirme tedavisinde sıklıkla tercih edilen vakum şekillendirici plakların kullanımı sonucunda oluşan kontak nokta sayılarının, sentrik oklüzyon ile lateral hareketler esnasındaki oklüzal kuvvet parametrelerinin, oklüzyon ve disklüzyon sürelerinin T-Scan III ile değerlendirilmesidir. Araştırmamıza Yüzüncü Yıl Üniversitesi Diş Hekimliği Fakültesi Ortodonti Anabilim Dalı'nda sabit ortodontik tedavi uygulanmış ve pekiştirme tedavisine geçilmiş 25 birey dahil edilmiştir. Kontak nokta sayısı, sentrik oklüzyon ve lateral hareketler esnasındaki oklüzal kuvvet parametreleri, oklüzyon ve disklüzyon sürelerinin değerlendirilmesinde T-Scan III kullanılmıştır. Değerlendirmeler tedavi sonu, 3. ve 6. aylarda yapılmıştır. VŞP kullanımı sonucu herbir diş bölgesine düşen oklüzal kuvvet dağılımı, sağ anterior, sağ posterior, sol anterior ve sol posterior kuadranta ait oklüzal kuvvet dağılımı ile sağ yarım çene ve sol yarım çeneye ait oklüzal kuvvet dağılımı, lateral hareketlerde çalışan ve çalışmayan tarafa ait kuvvet dağılımı, oklüzyon ve disklüzyon süresi parametrelerinde tedavi sonu, 3. ay ve 6. ay arasında anlamlı fark bulunamıştır. VŞP kullanan bireylerde maksimum interküspidasyonda oklüzal kontak nokta sayısının tedavi sonu ve 3. ay ile tedavi sonu ve 6. ay arasında karşılaştırılması sonucunda: anterior bölge, posterior bölge ve toplam oklüzal kontak nokta sayısındaki artışın istatistiksel olarak anlamlı olduğu görülmüştür. VŞP kullanan bireylerde maksimum interküspidasyonda oklüzal kontak nokta sayısının 3. ay ve 6. aylar arasında karşılaştırılması sonucunda ise anterior böle, posterior bölge ve toplam oklüzal kontak nokta sayısı bakımından istatistiksel olarak anlamlı bir farklılık bulunmadığı tespit edilmiştir. Araştırmamızın sonuçlarına göre VŞP kullanan bireylerde ilk 3 ayda kontak nokta sayısında artış meydana geldiği ancak tedavi sonu, 3. ve 6. aylarda; herbir diş bölgesine düşen oklüzal kuvvet dağılımı, sağ anterior, sağ posterior, sol anterior ve sol posterior kuadranta ait oklüzal kuvvet dağılımı ile sağ yarım çene ve sol yarım çeneye ait oklüzal kuvvet dağılımı, lateral hareketlerde çalışan ve çalışmayan tarafa ait kuvvet dağılımı, oklüzyon ve disklüzyon süresi parametrelerinde anlamlı bir değişikliğin oluşmadığı belirlenmiştir.

Özet (Çeviri)

The aim of this syudy was to to evaluate effects of VFR appliance on the numbers of the occlusal contacts, the closure/excursive occlusal force parameters, occlusion and disclusion time during retention, by T-Scan III. A total of 25 subjects treated with fixed orthodontic appliance were included in this study. T-Scan III was used in the analysis of number of occlusal contacts, closure/excursive occlusal force parameters, occlusion and disclusion time. The evaluations were made 2 hours after debonding (T0), in the 3rdmonth (T1) and 6th month (T2) of the retention phase. No significant change was observed in the individual force percentages of each tooth, bilateral force distribution between the left and right sides of the arch, the percentage force in the anterior and posterior quadrants, excursive force parameters on working and non-working sides, occlusion and disclusion time. Occlusal cocntacts were significant increased at T0-T1 and T0-T2. However, there was no significant difference between T1 and T2. According to the results of this study it has been determined that VFR has no significant effect on closure/excursive occlusal force paremeters and occlusion-disclusion time while it increases the number of occlusal contacts especially in the first 3 months.

Benzer Tezler

  1. Katodik ark FBB yöntemi ile dekoratif amaçlı Cr-O-N kaplamaların üretilmesi

    Production of Cr-O-N coatings by cathodic arc PVD, for decorative purposes

    SEMİH ÖNCEL

    Yüksek Lisans

    Türkçe

    Türkçe

    2002

    Metalurji Mühendisliğiİstanbul Teknik Üniversitesi

    Metalurji Ana Bilim Dalı

    PROF. DR. MUSTAFA ÜRGEN

  2. Termoform kalıplarının üretim süreçlerinde verimliliğe etki eden faktörler

    Factors affecting efficiency in the production process of thermoforming molds

    HATİCE KÜBRA KÜRÜMOĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    2024

    Makine Mühendisliğiİstanbul Üniversitesi-Cerrahpaşa

    Ambalaj Teknolojileri Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ ORHAN SEVİNDİK

  3. Geleneksel toz metalurjisi yöntemiyle üretilen AISI 304L VE AISI 316L östenitik paslanmaz çeliklerin özelliklerine sinterleme koşullarının etkisi

    The effects of sintering conditions on properties of AISI 304L VE AISI 316L austenitic stainless steels produced via traditional powder metallurgy methods

    HULKİ DEHA AK

    Yüksek Lisans

    Türkçe

    Türkçe

    2014

    Metalurji Mühendisliğiİstanbul Teknik Üniversitesi

    Metalurji ve Malzeme Mühendisliği Ana Bilim Dalı

    PROF. DR. MUSTAFA KELAMİ ŞEŞEN

  4. Vakum ekstraksiyon'la doğum ile yenidoğan retinal kanaması arasındaki ilişkinin incelenmesi

    Başlık çevirisi yok

    ORHAN MUHARREM TURGUT

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1985

    Kadın Hastalıkları ve DoğumUludağ Üniversitesi

    Kadın Hastalıkları ve Doğum Ana Bilim Dalı

  5. Vakum altında döküm fırınının PLC ile otomatik kontrolü

    Automatic control of a casting furnace under vacuum with PLC

    HAKAN ÖZTÜRK

    Yüksek Lisans

    Türkçe

    Türkçe

    1999

    Makine MühendisliğiYıldız Teknik Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    PROF. DR. FARİS KAYA