Geri Dön

Orofaringeal hava yolu ölçümünde kullanılan farklı alt referans düzlemlerin tekrar edilebilirliğinin karşılaştırılması

Evaluation of the examiner reliabilities of lower border planes used for volumetric measurement of pharyngeal airway

  1. Tez No: 534083
  2. Yazar: ŞAHİN BARIŞ
  3. Danışmanlar: DOÇ. DR. ASLIHAN UZEL
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: KHBT, Orofaringeal Havayolu, Güvenilirlik, Farenks, Konik ışınlı bilgisayarlı tomografi, Kraniyofasiyal yapı, Ortodonti, Referans değerler, Solunum, Solunum sistemi, CBCT, Oropharyngeal airway, Reliability, Pharynx, Cone-beam computed tomography, Craniofacial morphology, Orthodontics, Reference values, Respiration, Respiratory system
  7. Yıl: 2018
  8. Dil: Türkçe
  9. Üniversite: Çukurova Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Ortodonti Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmanın amacı KHBT üzerinden hacimsel hava yolu ölçümünde kullanılan farklı alt referans düzlemlerin gözlemciler arası ve gözlemci içi güvenilirliğinin karşılaştırılmasıdır. Çalışmamızda 35 iskeletsel Sınıf I bireye ait (ortalama yaş: 18,9±3,4 yıl) Konik Hüzmeli Bilgisayarlı Tomografi (KHBT) görüntüleri kullanılmıştır. Hacimsel hava yolu ölçümleri Dolphin 3D (Dolphin Imaging and Management Solutions, Chatsworth, California) programı kullanılarak yapılmıştır. Her grafiye ait ölçümler farklı tecrübe düzeylerinde olan üç gözlemci tarafından yapılmış ve iki hafta ara ile ikinci kez tekrarlanmıştır. Orofaringeal hava yolu hacim ölçümünde etki edebilecek diğer tüm değişkenler sabit tutularak ölçümler ikinci servikal vertebranın en alt ve ön noktası(CV2ai), üçüncü servikal vertebranın en alt ve ön noktası(CV3ai), epiglottisin ucu(EP) ve yumuşak damağın en uç noktası (SP) alt sınırları ile tekrarlanmıştır. Gözlemciler arası ve gözlemci içi uyuma sınıf içi korelasyon testi (SKK) ile bakılmıştır. Her dört parametre için tekrarlanabilirlik katsayıları (TEK), tekrarlayan ölçüm tasarımında gözlemci içi, gözlemciler arası ve toplam varyans bileşenleri kullanılarak hesaplanmıştır. İstatistiksel analiz sonucunda tüm ölçülen değişkenler için güvenilirlik mükemmel (ICC ≥ 0.9) bulunmuştur. Gözlemci içi ve gözlemciler arası en dar güven aralığı ve en yüksek tekrar edilebilirlik CV2, CV3, SP ve EP sırası ile bulunmuştur. Çalışmamızın bulgularına göre incelenen referans düzlemlerin güvenilirliği konusunda herhangi bir fark bulunmamasına karşın, kemiksel referans düzlemler, yumuşak doku referans düzlemlerine kıyasla daha yüksek tekrarlanabilirliğe sahiptir. Havayolu çalışmalarının veri standardizasyonunu sağlayabilmek için, kullanılacak alt referans düzleminin belirlenmesi konusunda görüş birliğine varılması önemlidir.

Özet (Çeviri)

The aim of this study is to assess the intra-examiner and inter-examiner reliabilities of different lower border planes used for volumetric measurement of oropharyngeal airway in CBCT. The study consists of CBCT scans of 35 skeletal Class I subjects (mean age: 18,9±3,4years). The volume from each scan was measured by using four commons used lower airway borders on Dolphin 3D software (Dolphin Imaging and Management Solutions, Chatsworth, California). Three researchers with different levels of experience independently made volumetric measurements twice with two week interval. With keeping all other variables constant, oropharyngeal airway volumes measured four times for each scan with the most anterior and inferior point of second cervical vertebrae(CV2ai), the most anterior and inferior point of third cervical vertebrae(CV3ai), tip of epiglottis(EP) and tip of soft palate(SP) as lower limit. The intraclass correlation coefficient (ICC) was used to assess intra-examiner and inter-examiner reliabilities. Repeatability coefficients (RC) for each 4 parameters were calculated by using interexaminer, intraexaminer and total variance components in the repetitive measurement design. As a result of statistical analysis reliability was found excellent (ICC ≥ 0.9) for all measured variants. Narrowest confidence interval and highest Repeatability for both interexaminer and intraexaminer measurements found in CV2 which fallowed by CV3, SP and EP respectively. According to the findings of our study although there is no big differences in reliability of all these borders, bony structures has higher repeatability than soft tissue ones. Due to the standardization need for the data of pharyngeal airway studies a consensus should be achieved.

Benzer Tezler

  1. Horlamanın uvulopalatofarengoplasti (UPPP) ile tedavisi

    Başlık çevirisi yok

    ÜNER İHSAN ŞAHİN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1989

    Kulak Burun ve BoğazErciyes Üniversitesi

    Kulak Burun Boğaz Ana Bilim Dalı

  2. Myastenia gravisde klinik, laboratuvar bulguları ve sonucu etkileyen faktörler

    Başlık çevirisi yok

    OKTAY GÖNLÜŞEN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1991

    NörolojiÇukurova Üniversitesi

    Nöroloji Ana Bilim Dalı

  3. Alt solunum yolları enfeksiyonlarında moraxella catarrhalisin prevalansı ve beta laktamaz aktivitesinin saptanması

    Başlık çevirisi yok

    MASOUMEH ASLANİ MEHR

    Yüksek Lisans

    Türkçe

    Türkçe

    1993

    MikrobiyolojiDokuz Eylül Üniversitesi

    Mikrobiyoloji Ana Bilim Dalı

    DOÇ. DR. AYŞE YÜCE

  4. Alt solunum yolu infeksiyonlarında PSB tekniği ile bakteriyolojik değerlendirme ve serolojik inceleme

    Bacteriologic evaluation with PSB technique and serologic testing in lower respiratory tract infections

    MEHMET KUTLU ÇELENK

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1996

    Göğüs HastalıklarıAnkara Üniversitesi

    PROF.DR. UĞUR GÖNÜLLÜ