Endüstriyel tip ıslak soğutma kulelerinin deneysel ve teorik analizi

Experimental and theoretical analysis of industrial type wet cooling towers

  1. Tez No: 548444
  2. Yazar: GÖRKEM ZENGİN
  3. Danışmanlar: DOÇ. DR. AYHAN ONAT
  4. Tez Türü: Yüksek Lisans
  5. Konular: Makine Mühendisliği, Mechanical Engineering
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2019
  8. Dil: Türkçe
  9. Üniversite: Marmara Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Makine Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Makine Mühendisliği Bilim Dalı
  13. Sayfa Sayısı: 77

Özet

Soğutma kuleleri fabrikalarda, enerji üretim tesislerinde ve konut tipi yapıların iklimlendirmelerinde, özetle soğuk su ihtiyacı olan yerlerde kullanılan yüksek verimli ve düşük maliyetli soğutma üniteleridir. Basitçe çalışma prensiplerini tanımlamak gerekirse; prosesteki sıcak suyun içeriğindeki ısıyı soğuk havaya dolgular ve spreyleme teçhizatlarının da yardımıyla aktararak ısı transferi yapan ekipmanlardır. Bu ısı aktarımının termal verimini arttırmak için birbirinden farklı çok sayıda sistem tasarımları bulunmaktadır. Bu tasarımlardan biri de dolgu yüksekliğinin değiştirilmesidir. Bu çalışmada dolgu yüksekliğindeki değişikliklerin performansa etkisi incelenmiştir. Deneysel olarak yapılan çalışmada dört farklı yükseklikteki dolgunun ampirik hesaplama katsayıları çıkartılmıştır. Dezavantajları ve avantajları incelenmiştir. 1500, 1800, 2100 ve 2400 mm'lik dolgu yüksekliklerinde performans testleri yapılmıştır. Bu testlerde termal giriş çıkış sıcaklıkları ölçülmüş ve sonucunda termal hesaplama korelasyon katsayıları çıkartılmıştır. Merkel yaklaşımına göre performansı en düşük olan 1500 mm'lik dolgu olurken en yüksek performans 2400 mm'lik yüksekliğe sahip olan dolgu yüksekliğinde çıkmıştır. Termal performans testlerinin yapıldığı sırada dolgudaki basınç kaybı değeri de her koşulda ayrı ayrı ölçülmüştür. Bu ölçümler sonucunda da farklı dolgu yüksekliklerinde, hava hızlarında ve su yüklerindeki hava direnci değerlerini veren grafikler elde edilmiştir. En düşük direnç değeri 1500 mm'lik dolguda ölçülürken en yüksek değer de 2400 mm'lik dolguda ölçülmüştür. Soğutma kuleleri dizaynında dolgu yüksekliği ne kadar artırılırsa performans o kadar artmaktadır, lakin bu artışla birlikte hava tarafı direnci de artmaktadır.

Özet (Çeviri)

Wet cooling towers are high thermal efficient and cost effective industrial cooling units which are used in factories, energy plants and heating, ventilating and air conditioning sector (HVAC). For simply describe of the working principles; hot process water cools with cold atmosphere air by the help of cooling fills and water distribution systems. There are many different system designs to increase the thermal efficiency of this heat transfer. One of these designs is to change the fill height. In this study, the effect of fill height changes on thermal performance are investigated. In the experimental study, four different cooling fill height's empirical calculation coefficients are found. Disadvantages and advantages are examined. Performance tests were performed at fill heights of 1.500, 1.800, 2.100 and 2.400 mm. In these tests, thermal input output temperatures were measured and thermal correlation coefficients were calculated. According to the Merkel approach, 1500 mm has the lowest and 2.400 mm has the highest performance coefficient about cooling fill height change. During thermal performance tests, the pressure loss value on cooling fill was measured separately in each condition. With these measurements, graphs were obtained for different fill heights, air velocity and water loading values. The lowest resistance value is measured on 1500 mm fill height and the highest resistance value is measured in the 2400 mm fill. Increased cooling fill height will improve thermal performance but higher height cooling fill will make more pressure loss on air side.

Benzer Tezler

  1. Havanın soğutulması ve neminin alınması amacıyla kullanılan kanatlı borulu ısı değiştiricilerin kuramsal ve deneysel incelenmesi

    Theoretical and experimental analysis of finned tube wet coils

    ALTAY ARBAK

    Yüksek Lisans

    Türkçe

    Türkçe

    2014

    Makine Mühendisliğiİstanbul Teknik Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    PROF. DR. ALİ TANER DERBENTLİ

  2. Endüstriyel ölçekli bir soğuk hava deposunun soğutma yükü hesabı veC02/NH3 kaskad soğutma sisteminin incelenmesi

    Cooling load of an industrial refrigeration facility and analysing of C02/NH3 cascade refrigeration system

    ÜNAL TİRYAKİ

    Yüksek Lisans

    Türkçe

    Türkçe

    2021

    Makine Mühendisliğiİstanbul Üniversitesi-Cerrahpaşa

    Makine Mühendisliği Ana Bilim Dalı

    PROF. DR. EROL UZAL

  3. Bitkisel yağlardan çözücü ekstraksiyonu ile serbest yağ asitlerinin giderilmesinin ardından çözücünün iyon değişimi ile geri kazanılması

    Ion exchange for solvent recovery in deacidification of vegetable oils by solvent extraction

    MELİKE ERGUVAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2016

    Kimya Mühendisliğiİstanbul Teknik Üniversitesi

    Kimya Mühendisliği Ana Bilim Dalı

    PROF. DR. HALE GÜRBÜZ

  4. Laktik asidin mısır kepeğinden fermentasyonla üretimi ve iyon değiştirici reçineler ile saflaştırılması

    Lactic acid production from corn fiber by fermentation and purification with ion-exchange resins

    TUĞBA KONCA

    Doktora

    Türkçe

    Türkçe

    2021

    BiyoteknolojiSakarya Üniversitesi

    Biyoloji Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ KENAN TUNÇ