Tam otomatik bakır ölçüm kitinin geliştirilmesi
Fully automated copper measurement kit development
- Tez No: 559474
- Danışmanlar: PROF. DR. ŞAHBETTİN SELEK
- Tez Türü: Doktora
- Konular: Biyokimya, Biochemistry
- Anahtar Kelimeler: bakır, oto-analizör, kolorimetri, performans değerlendirmeleri, copper, automated analyzers, colorimetry, performance evaluation
- Yıl: 2019
- Dil: Türkçe
- Üniversite: Bezm-i Alem Vakıf Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Tıbbi Biyokimya Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: 119
Özet
Klinik kimya hastalıkların tanı ve tedavisinde uygulanan tetkiklerle ilgilenir. Tıp alanında uygulanan laboratuvar testlerinin temelini otomatize analizörler oluşturmasına rağmen bir çok analitin tayini hala otomatize sistemlere uyumlu hale getirilememiştir. Bakır tayininde otomatize bir teknik olmayan atomik absorpsiyon spektrometrisi (AAS) yaygın olarak kullanılmaktadır. AAS her laboratuvarda sürekli uygulanan, kolay ulaşılabilir bir teknik değildir ve yapılacak ölçümler için örneklerin dış laboratuvarlara gönderilmesi gerekmektedir. Örneklerin dış laboratuvarlara gönderilmesiyle tetkikin sonucunun doktora ulaşması gecikmekte ve tetkik maliyetleri artmaktadır. Eser elementlerin pratik yöntemlerle ölçülebilmesi ve miktarlarında gerçekleşen değişimlerin takip edilebilmesi önemlidir. Bu elementler, çok önemli fizyolojik olaylarda görev alan enzimlerin yapı ve fonksiyonunda görevlidir. Bakır, demir metabolizması, hücresel solunum, serbest radikallerin etkisiz hale getirilmesi, bağ doku elemanlarının, nörotransmitter maddelerin sentezi ve sinir sisteminde sinyal iletimi başta olmak üzere bir çok metabolik yolakta anahtar rolü oynayan enzimlerin yapısında bulunur. Bakır metabolizmasındaki bozukluklar, eksikliğinde ve fazlalığında ciddi klinik bulguların görüldüğü bir çok hastalığa sebep olur. Bu çalışmada, AAS'ye ve piyasada kullanılan fakat verimli olmayan otomatize yöntemlere alternatif olarak doğru sonuçlar veren, raf ömrü ve cihaz üzerinde kullanım süresi uzun otomatize bir kolorimetrik bakır ölçüm kiti geliştirilmesi ve geliştirilen yöntemin klinik kullanıma uygunluğunun değerlendirilmesi hedeflenmiştir. Amaca yönelik olarak manuel ve otomatize spektrofotometri teknikleri kullanılarak reaktifler geliştirilmiş ve bu reaktiflerin klinik kullanıma uygunluğunun değerlendirmesi için performans ve stabilite değerlendirmeleri gerçekleştirilmiştir Geliştirilen yöntemin %CV değeri 2'nin altında, hata değeri -1 ile 1 arasındadır. Yöntem karşılaştırma çalışmalarında AAS ile 0.96 oranında korelasyon gözlemlenmiştir. Yapılan regresyon analizi sonucu elde edilen r2 değeri 0.95'tir. LoB 0.178 μg/dl, LoD 0.607 μg/dl, LoQ 3.207 μg/dl, toplam analitik hata 1.89, sigma 3.62, ölçüm belirsizliği 2.87, genişletilmiş ölçüm belirsizliği 5.74 olarak tespit edilmiştir. Yöntem 4-1000 μg/dl aralığında doğrusaldır. Carry-over gözlemlenmemiştir. Çinko, magnezyum, kobalt ve demir iyonları ölçümlerde interferense sebep olmamaktadır. Raf ömrü en az 6 ay, cihaz üzerinde kullanım süresi en az 30 gün olarak tespit edilmiştir. Referans aralığı 91-185 μg/dl olarak belirlenmiştir. Kesinlik, doğruluk, yöntem karşılaştırması, tespit kabiliyeti, doğrusallık, carry-over, girişim, raf ömrü ve cihaz üzerinde kullanım süresi değerlendirilen yöntemin klinik kullanıma uygun olduğu, altın standart yöntemle korele sonuçlar verdiği ve benzer kitlerden daha üstün performans sergilediği gözlemlenmiştir. Ülkemiz şartlarında üretimi mümkün dünya standartlarında performans sergileyen yeni bir ölçüm yöntemi geliştirilmiştir.
Özet (Çeviri)
Clinical chemistry deals with laboratory tests performed for diagnosis and treatment follow-up of diseases. Laboratory tests performed in medicine are heavily based on automated analyzers, however, analysis of many analytes have not yet been adapted to automated systems. For analysis of copper in biological fluids, AAS, a non-automated and not easily available technique is widely used. AAS is a technique that is not easy-to-perform and readily available in most hospital's routine clinical chemistry laboratory. Therefore, samples are transported to outside laboratories for copper measurement. This transport increases the costs and causes a delay in report of results to the requesting physician. Quick and easy analysis and follow-up of levels of trace elements is important. These elements carry very important roles in function and structure of key enzymes in important metabolic pathways. Copper plays key roles in many metabolic events such as iron metabolism, cellular respiration, free radical detoxification, synthesis of connective tissue elements and neurotransmitters, and neuronal signaling. Disorders of copper metabolism result in diseases with devastating clinical findings in case of deficiency and accumulation of copper. In this study, development and perfromance evaluations of a new reliable and stable automated clinical chmeistry method for copper measurement was aimed as an alternative to AAS and unstable and unreliable colorimetric techniques. Automated spectrophotometry techniques were used for this purpose. New reactives were developed and the performance of the new technique was analyzed for suitability in clinical use. CV% was lower than 2, bias was between -1 and 1. 0.96 correlation was observed with AAS. R2 was 0.95 on regression analysis. LoB 0.178 μg/dl, LoD 0.607 μg/dl, LoQ 3.207 μg/dl were observed. Total analytical error was 1.89, sigma was 3.62, combined measurement uncertainty was 2.87 while expanded measurement uncertainty was 5.74. The method is linear between 4-1000 μg/dl. No carry-over effect was observed. No interference with zinc, magnesium, cobalt and iron ions were observed. Shelf-life is at least 6 months, and on-board stability was at least 25 days. Reference interval is 91-185 μg/dl. The method is suitable for clinical use. A new method with performance suitable for global standards and producible in Turkey is developed.
Benzer Tezler
- Prediction of COVID 19 disease using chest X-ray images based on deep learning
Derin öğrenmeye dayalı göğüs röntgen görüntüleri kullanarak COVID 19 hastalığının tahmini
ISMAEL ABDULLAH MOHAMMED AL-RAWE
Yüksek Lisans
İngilizce
2024
Bilgisayar Mühendisliği Bilimleri-Bilgisayar ve KontrolGazi ÜniversitesiBilgisayar Mühendisliği Ana Bilim Dalı
PROF. DR. ADEM TEKEREK
- Derin öğrenme ve büyük veri analitiği yöntemleriKullanarak Covid-19 yayılımının ileriye dönük tahmini
Forecasting the spread of covid-19 using deep learning and big data analytics methods
CYLAS KIGANDA
Yüksek Lisans
İngilizce
2023
Bilgisayar Mühendisliği Bilimleri-Bilgisayar ve KontrolGazi ÜniversitesiBilgisayar Bilimleri Ana Bilim Dalı
PROF. DR. MUHAMMET ALİ AKCAYOL
- Farklı taşlama koşullarında oluşan akustik emisyon faaliyetlerinin kısa zamanlı Fourier dönüşümü ile incelenmesi
Investigation of acoustic emission activities under different grinding conditions using short time Fourier transform
ONUR BAKIR
Yüksek Lisans
Türkçe
2021
Makine MühendisliğiUşak ÜniversitesiMakine Mühendisliği Ana Bilim Dalı
PROF. DR. İSA YEŞİLYURT
- Adenozin deaminaz(ADA) enziminin kinetik özellikleri, otomatik analizör ile aktivite ölçümü, tüberküloz ve lepra hastalarında serum ada aktivitesi ve bazı biyokimyasal parametreler
Başlık çevirisi yok
ÖZCAN EREL
Tıpta Uzmanlık
Türkçe
1992
BiyokimyaFırat ÜniversitesiBiyokimya ve Klinik Biyokimya Ana Bilim Dalı
DOÇ. DR. YÜKSEL ÖZDEMİR