Design and fabrication of fiber optic integrated sensor microsystem for interventional medical devices

Girişimsel tıbbi cihazlar için fiber optik tümleşik algılayıcı mikrosistem tasarımı ve üretimi

  1. Tez No: 651203
  2. Yazar: OĞUZ KAAN ERDEN
  3. Danışmanlar: PROF. DR. ARDA DENİZ YALÇINKAYA
  4. Tez Türü: Yüksek Lisans
  5. Konular: Elektrik ve Elektronik Mühendisliği, Biyomühendislik, Electrical and Electronics Engineering, Bioengineering
  6. Anahtar Kelimeler: Biyosensörler, Optik sensörler, Biosensors, Optical sensors
  7. Yıl: 2020
  8. Dil: İngilizce
  9. Üniversite: Boğaziçi Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Elektrik-Elektronik Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmada, Manyetik Rezonans Görüntüleme (MRG) destekli girişimsel radyolojik uygulamalar için basınç, sıcaklık ve lokalizasyon bilgilerinin gerçek zamanlı olarak izlenebildiği bir tıbbi cihaz prototipinin tasarım, üretim ve karakterizasyon çalışmaları sunulmuştur. Sistem, iç çapı 2.2 mm olan bir platform üzerinde üretilen mikro elektro mekanik sistem (MEMS) sensörleri, fiber optik bileşenleri ile birleştirerek ameliyatta kullanılan tıbbi cihazın konumunu ve çevresel koşulların gerçek zamanlı olarak belirlenmesine olanak tanır. Sistem temel olarak, her bir bileşenin optik olarak ölçüm aldığı ve verileri aynı şekilde detektörlere ilettiği lokalizasyon, sıcaklık ve basınç sensörlerinden oluşur. Konum tespiti, ışığın polarizasyonundaki değişim ile örnek yüzeyinin manyetizasyonunu ölçmek için kullanılan bir yöntem olan Manyeto Optik Kerr Etkisi (MOKE) gözlemi sayesinde gerçekleştirilir. MR gradyan alanı ile oluşturulan, kontrol edilebilir 30 mT manyetik alan aralığında, hassasiyet değerleri, 430 kalite çelik için 0.475 mm ve Fe2O3 için 4.44 mm olarak rapor edilmiştir. Ortam sıcaklığının algılanması, GaAs yarıiletken malzemenin enerji bant aralıklarının, sıcaklığa bağlı olarak değişimi esas alınarak gerçekleştirilir. Bu değişim, sıcaklığa bağlı olarak, yarıiletkenin soğurma katsayısının değişimine sebep olmaktadır. Yarıiletkenden yansıyan ışığın dalga boyunun, yarıiletkenin ölçülmek istenen sıcaklıktaki enerji bant aralığı değeri ile orantılı olarak değişmektedir. Sensörün hassasiyeti 0.494 nm/°C olarak rapor edilmiştir. Çevresel basınç ise, metalik zarın oda basıncı baz alınarak zar üzerinde gerçekleşen bükülmenin interferometrik olarak okunması ile ölçülür. Farklı tasarlanmış membranlar arasında en iyi hassasiyet, 200 µm çaplı sensör ile 1.456 mV / mmHg olarak ölçülmüştür.

Özet (Çeviri)

In this thesis, there is presented the design, fabrication and characterization of a medical device prototype for real time monitoring of pressure, temperature and localization information for Magnetic Resonance Imaging (MRI) supported interventional radiological applications. The system allows to determine the position of the medical device used in surgery, as well as environmental conditions in real time by combining fiber optical components with micro electro mechanical system (MEMS) sensors, fabricated on an inner diameter of 2.2 mm platform. The system mainly consists of localization, temperature and pressure sensors, where each component takes measurement optically, and transmits data in the same way. The localization detection is realized due to the observation of Magneto Optical Kerr Effect (MOKE), which is a method to measure the magnetization of the sample surface by the change in the polarization of the light. In the controllable magnetic field area, which is created by gradient field, the precision is reported for steel grade 430 as 0.475 mm and for Fe2O3 as 4.44 mm. Ambient temperature sensing is based on absorption change in semiconductor due to variations of energy bandgap of a GaAs sample with temperature. Incident light, at a specific wavelength, on the GaAs is reflected back with the temperature change signature. The sensitivity of the sensor is reported as 0.494 nm/°C. Lastly, the environmental pressure change with respect to chamber pressure of the metallic membrane is measured interferometrically. Among different designs, the best sensitivity is reported as 1.456 mV/mmHg by 200 µm diameter sized sensor.

Benzer Tezler

  1. İzmir'de bazı yolların kapatılarak yaya bölgeleri oluşturma da kent peyzajını geliştirme açısından yeniden planlanması üzerinde araştırmalar

    Başlık çevirisi yok

    BAHAR TÜRKYILMAZ

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Şehir ve Bölge Planlama Ana Bilim Dalı

    Yükleniyor...

  2. Ağızlık açma mekanizmalarının tasarımı

    Başlık çevirisi yok

    RECEP EREN

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    Uludağ Üniversitesi

    Tekstil Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  3. Sonbahar sera yetiştiriciliğine uygun hıyar çeşit seçimi

    Selecting a cucumber variety suitable for glasshouse production in Autumn

    MESUT OKTAY

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Yükleniyor...

  4. İki katlı pamuk ipliklerinden dokunan kumaşlarda örgüye bağlı olarak maksimum atkı sıklığının değişimi üzerinde bir araştırma

    Başlık çevirisi yok

    MELTEM ASLI NARTER

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Tekstil Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  5. Küçük Yamanlar tepesi örneğinde kent yakın çevresinde rekreasyon alanı düzenleme projesi

    Başlık çevirisi yok

    NİHAN BULGUN

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Peyzaj Mimarlığı Ana Bilim Dalı

    Yükleniyor...

  6. Çukurova bölgesinde biyoklimatik veriler kullanılarak açık ve yeşil alan sistemlerinin belirlenmesi ilkeleri üzerinde bir araştırma

    A research on the determination of the principles in open and green spaces systems by using the bioclimatic data in Çukurova region

    MEHMET FARUK ALTUNKASA

    Doktora

    Türkçe

    Türkçe

    1987

    Çukurova Üniversitesi

    Peyzaj Mimarlığı Ana Bilim Dalı

    Yükleniyor...