Geri Dön

Farklı dayanak materyallerinin hemen yükleme sonrası implant çevresi dokulara etkisinin karşılaştırılması: in vivo çalışma

Compari̇son of the effects of di̇fferent temporary abutment materi̇als on peri̇-i̇mplant ti̇ssues after i̇mmedi̇ate loadi̇ng: in vivo study

  1. Tez No: 658595
  2. Yazar: İLKAY GÜL
  3. Danışmanlar: PROF. DR. MUSTAFA ZORTUK
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Hemen Yükleme, PEEK, Titanyum, Dayanak, Dental implantasyon, Dental implantlar, Dental materyaller, Dental restorasyon, Takma diş tabanları, İn vivo, Immediate Loading, PEEK, Titanium, Abutment, Dental implantation, Dental implants, Dental materials, Dental restoration, Denture bases, In vivo
  7. Yıl: 2019
  8. Dil: Türkçe
  9. Üniversite: Hatay Mustafa Kemal Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Farklı Dayanak Materyallerinin Hemen Yükleme Sonrası İmplant Çevresi Dokulara Etkisinin Karşılaştırılması: İn Vivo Çalışma Giriş ve Amaç:Titanyum; mükemmel üstün fiziksel ve mekanik özellikleri göz önüne alınarak, dayanak materyalleri açısından altın standart olarak kabul edilmektedir. Ancak günümüzde titanyum, estetiğin ön planda olduğu bölgelerde, sahip olduğu metalik rengin implant çevresi mukozada oluşturduğu grimsi yansıma nedeniyle estetik bakımdan yetersiz kalmaktadır. Bu çalışmanın amacı, hemen yükleme protokolüyle titanyum dayanaklar üzerine hazırlanan geçici restorasyonlara alternatif olarak, PEEK dayanak kullanılarak hazırlanan geçici restorasyonların, implant çevresi kemikte meydana gelen kemik kaybına ve implant çevresindeki dokulara etkisinin in vivo olarak incelenmesidir. Gereç ve Yöntem: Bu çalışma, 21 hastaya (13 kadın, 8 erkek) uygulanan 32 implant üzerine titanyum ve PEEK dayanaklar kullanarak (14 titanyum ve 18 PEEK) hazırlanan geçici restorasyonlar ile gerçekleştirildi. İmplantların cerrahi olarak yerleştirilmesinden önce, hastanın ağız içi, ağız dışı ve radyografik muayeneleri yapıldı. Hastalar titanyum dayanak grubu (Grup Ti) ve PEEK dayanak grubu (Grup PEEK) olacak şekilde iki gruba ayrıldı. Her iki grupta da tüm implantlar, üretici firmanın önerileri doğrultusunda, cerrahi olarak kemiğe yerleştirildi. Cerrahi işlem bitiminde implantların ölçüsü kapalı kaşık ölçü tekniği ile polivinilsiloksan ölçü maddesi kullanılarak implant seviyesinde alındı. Model üzerinde oluşturulması düşünülen dişeti kazınarak gruplara göre uygun titanyum veya PEEK dayanaklar analoğun üzerine vidalandı ve geçici restorasyon hazırlanarak hastaya uygulandı. İmplant çevresi kemik seviyesi, ISQ değerleri, sondalama derinliği, kanama indeksi, gingival indeks, plak indeksi ve keratinize dişeti yüksekliği miktarları; operasyon günü, 1. ay sonunda ve 3. ay sonunda olacak şekilde ölçülerek kaydedildi. Çalışmamızda elde edilen verilerin normalitesi Shapiro-Wilks testi kullanılarak p=0,05 anlamlılık düzeyinde değerlendirildi. Ölçülen kemik kaybı ve ISQ değerleri ve bu değerler üzerine faktör etkileşimleri tekrarlanan ölçümler ANOVA testi ve Bonferroni düzelmesi kullanılarak Post-Hoc Tukey HSD testi ile p=0,05 anlamlılık düzeyinde değerlendirildi. Hastalardan elde edilen niceliksel verilerin birbirleriyle olan ilişkileri ise; p=0,05 anlamlılık düzeyinde Pearson korelasyon analizi kullanılarak değerlendirildi. Bulgular: Yapılan istatistiksel değerlendirmeler doğrultusunda, dayanak çeşidinin ISQ değerleri üzerine anlamlı bir etkisinin olmadığı (p>0,05), dayanak çeşidinden bağımsız şekilde implant çapının ISQ değerleri üzerinde etkili olduğu (p<0,05) görüldü. PEEK dayanak kullanılan grupta titanyum dayanak grubuna göre daha az marjinal kemik kaybı gözlendiği (p<0,05). Periodontal skorlar bakımından iki grupta da benzer sonuçlar elde edildiği (p>0,05) görüldü. Sonuçlar: Bu çalışmanın limitasyonları dahilinde; PEEK dayanak kullanılan hasta grubunda daha az kemik kaybı olduğu (p<0,05), PEEK ve titanyum dayanaklar arasında ISQ değerleri ve klinik değerlendirmeler bakımından farklılık gözlenmediği (p>0,05) implant boyunun ISQ değerleri üzerine anlamlı bir etkisi olmadığı (p>0,05) implant çapının ISQ değerleri üzerine anlamlı bir etkisi olduğu görüldü. (p<0,05).Uygun dayanak materyali seçimi, implantların uzun dönem başarısı üzerine etkili olduğu gözlendi.

Özet (Çeviri)

ABSTRACT Comparison of the Effects of Different Temporary Abutment Materials on Peri-implant Tissues After Immediate Loading: In Vivo Study Introduction and Aim: Titanium is considered to be the gold standard among the abutment materials, given its excellent superior physical and mechanical properties.However, it is insufficient in aesthetic areas due to the grayish reflection caused by metallic color around the implant.The aim of this study was to evaluate the effect of PEEK abutments, an alternative to titanium abutments, with acrilic temporary restorations using immediate loading protocol on the marginal bone loss and periimplant tissues. Materials and Methods:This study was performed with temporary restorations using 32 titanium and PEEK abutments (14 titantum and 18 PEEK) on 32 implants performed on 21 patients (13 females, 8 males). Before surgical placement of the implants, intraoral and radiographic examinations were performed. The patients were divided into two groups as titanium abutment group (Grup Ti) and PEEK abutment group (Grup PEEK).In both groups, all implants were placed according to the manufacturer's recommendations. After surgery, impressions were taken using polyvinyl siloxane impression material and closed spoon impression technique.The gingiva which is thought to be formed on the model was scraped and screwed onto the appropriate titanium or PEEK abutment analogue according to the groups and temporary restoration was prepared and applied on the implant.The data were evaluated using repeated measures ANOVA and Post-Hoc Tukey HSD test with Bonferroni correction(a:0.05) at a significance level of p=0.05.The relationships between the quantitative data were evaluated using Pearson correlation analysis at p=0.05 significance level. Results:.The results of the statistical analysis show that abutment type have no significant effect of the abutment type on ISQ values (p> 0.05), but the diameter of implant significantly affected ISQ values independently from abutment type (p <0.05). Less marginal bone loss was observed in the PEEK abutment group compared to the titanium abutment group (p <005), and similar results were obtained in both groups in terms of periodontal scores (p> 0.05). Conclusions:Within the limitations of this study; there was less bone loss in the PEEK abutment group (p <0.05). There was no difference between PEEK and titanium abutments in terms of ISQ values and clinical evaluations (p> 0.05). Implant length did not have a significant effect on ISQ values (p> 0.05), and implant diameter had a significant effect on ISQ values. (P <0.05). Suitable abutment material selection is effective on the long-term success of implants.

Benzer Tezler

  1. Mandibular iki implant destekli overdenturelarda kantilever peek bar tasarımının implantlar etrafındaki strese etkisi

    The effect of cantilever peek bar design on stress around implants in mandibular two implant supported overdenture prostheses

    NAZLICAN GÜNEŞ

    Doktora

    Türkçe

    Türkçe

    2026

    Diş HekimliğiEge Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. AYŞE GÖZDE TÜRK

  2. Bazı esterlerin kinetik incelenmesi ve termodinamik parametrelerin belirlenmesi

    Kinetic study and detesmination of thermodnamic parameters of some esters

    İBRAHİM TAŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Kimya MühendisliğiUludağ Üniversitesi

    Kimya Ana Bilim Dalı

    PROF. DR. MUSTAFA CEBE

  3. Testosteron dihidrotestosteron ve östrojenin benign prostat hiperplazisindeki etyolojik rolleri

    The roles of testosterone, dihydrotestosterone and estradiole on the etiology of benign prostatic hyperplasia

    HALUK TOKUÇOĞLU

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1986

    ÜrolojiGazi Üniversitesi

    Üroloji Ana Bilim Dalı

  4. Süt formüllerinin tüketim uygulamaları ve süt formüllerinin C vitamini içeriği ile pH değerleri

    Başlık çevirisi yok

    GÖNÜL VAROL

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Besin Hijyeni ve Teknolojisiİstanbul Üniversitesi

    Çocuk Gelişimi Ana Bilim Dalı

    DOÇ. DR. TÜRKAN KUTLUAY