Geri Dön

Bilgisayarlı tomografi görüntülerinde foramen sphenopalatina'nın morfometrik ve klinik açıdan değerlendirilmesi

Morphometric and clinical evaluation of foramen sphenopalatina on computed tomography images

  1. Tez No: 686570
  2. Yazar: BÜŞRA ŞEKER
  3. Danışmanlar: PROF. DR. AYNUR EMİNE ÇİÇEKCİBAŞI
  4. Tez Türü: Yüksek Lisans
  5. Konular: Anatomi, Kulak Burun ve Boğaz, Anatomy, Otorhinolaryngology (Ear-Nose-Throat)
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2021
  8. Dil: Türkçe
  9. Üniversite: Necmettin Erbakan Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Anatomi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 118

Özet

Epistaksis, KBB uzmanlarının klinikte sık karşılaştıkları bir durumdur. Woodruff pleksusunun yerleştiği alandan kaynaklanan, daha inatçı, şiddetli ve tehlikeli vakalar, posterior epistaksis olarak adlandırılır. Woodruff pleksusu, a. sphenopalatina'nın for. sphenopalatinum (FSP)'dan çıktığı bölgede yer alır. Konservatif tedavilere dirençli olan posterior epistaksis, genellikle a. sphenopalatina ligasyonunu gerektirir. A. sphenoplatina ligasyonuna yönelik en doğru endoskopik yaklaşım yönteminin belirlenmesi, doğrudan FSP üzerindeki daha küçük mukoperiosteal flebin kaldırılması ve a. sphenopalatina'nın diğer yapılardan daha kolay ayırt edilebilmesi FSP'nin lokalizasyonunun doğru tanımlanmasıyla mümkündür. Çalışmamızın amacı; belirlenen sabit anatomik landmarklar yardımıyla FSP'nin lokalizasyonunun tespit edilmesi ve elde edilen ölçüm değerleriyle FSP varyasyonları arasındaki ilişkinin analiz edilmesidir. Çalışmada; Necmettin Erbakan Üniversitesi Meram Tıp Fakültesi Radyoloji A.D arşivinde bulunan 2019-2021 yılları arasında çekilmiş MDBT temporal kemik görüntüleri retrospektif olarak incelendi. Parametreler 153 hastada sağ-sol taraf için ayrı ayrı ölçülerek kaydedildi. Elde edilen verilerle varyasyon bilgileri cinsiyet, lateralizasyon ve yaş gruplarına göre değerlendirilerek sonuçlar tablolarla özetlendi. Morfometrik verilerin çoğunda sağ-sol arasında anlamlı fark bulunmazken, cinsiyete göre FSP-SNAaçı dışındaki verilerin erkeklerde anlamlı derecede daha yüksek olduğu bulundu. Belirli yaş gruplarına ayırarak yapılan istatistiki analizde, morfometrik verilerin yarısında yaş grupları arasında anlamlı bir fark bulunmazken FSP-SNAsaguzaklık dışında diğer morfometrik veriler 1. yaş grubunda (18-34 Y) anlamlı derecede daha yüksek olduğu saptandı. FSP'nın şekil, sayı ve konum varyasyonlarıyla birlikte pnömatizasyon ve septum deviasyonu varyasyonlarının cinsiyet, lateralizasyon ve yaş gruplarına göre dağılımı tablolarda gösterildi. CNM'de pnömatizasyon varlığı durumunda tüm morfometrik uzaklık değerlerinin daha küçük olduğu ve FSP-BTveruzaklık, FSP-CAsaguzaklık, FSP-MLsaguzaklık, FSP-SNAuzaklık ve FSP-SNAsaguzaklık değerlerinin istatistiki açıdan anlamlı ölçüde daha küçük olduğu, FSP-SNAaçı değerinin ise büyük olduğu tespit edildi. FSP'nin CNM'nin tutunma noktasının konumuna göre lokalizasyonu ve septum deviasyonuna göre oluşturulan tipler arasında morfometrik ölçüm değerlerinin istatistiki açıdan anlamlı bir farklılık göstermediği bulundu. Literatürde farklı ırklarda kemik yapıdaki sabit anatomik landmarklarla FSP lokalizasyonunu belirlemeyi amaçlayan birkaç çalışma mevcuttur. FSP şekil ve varyasyonları ligasyon işlemi sırasında FSP'nin yerini belirlemeyi zorlaştırabilir. Özellikle %7,9 çift ve %1 üç delik şeklinde bulunan aksesuar FSP varlığı ligasyon işleminin yetersiz olmasına neden olabilir. Türk popülasyonunda yeterli çalışma bulunmayan bu konudaki çalışmamızda elde ettiğimiz verilerin, epistaksisin tanı ve tedavisinde, özellikle endoskopik FSP yaklaşımlarında, bu bölgenin karmaşık anatomisini daha iyi anlamada yardımcı olacağı kanaatindeyiz.

Özet (Çeviri)

Epistaxis is a condition frequently encountered by ENT specialists in the clinic. More stubborn, severe and dangerous cases originating from the area where Woodruff's plexus is located are called posterior epistaxis. Woodruff's plexus is located in the region where the sphenopalatine artery emerges from the foramen sphenopalatinum (FSP). Posterior epistaxis resistant to conservative treatments usually requires ligation of the sphenopalatine artery. Determining the most accurate endoscopic approach method for sphenoplatinum artery ligation is possible by raising the smaller mucoperiosteal flap directly over the FSP and distinguishing the sphenopalatine artery from other structures more easily by accurately defining the localization of the FSP. The aim of our study is to determine the localization of FSP with the help of fixed anatomical landmarks and to analyze the relationship between the obtained measurement values and FSP variations. In the study; MDCT temporal bone images taken between 2019-2021 in the archive of Necmettin Erbakan University Meram Faculty of Medicine, Department of Radiology were retrospectively analyzed. Parameters were measured and recorded separately for the right and left sides in 153 patients. With the obtained data, variation information was evaluated according to gender, lateralization and age groups, and the results were summarized in tables. While there was no significant difference between right and left in most of the morphometric data, the data other than the FSP-SNAaçı were found to be significantly higher in males. In the statistical analysis performed by dividing them into certain age groups, no significant difference was found between the age groups in half of the morphometric data, while the other morphometric data were found to be significantly higher in the 1st age group (18-34 Y), except for FSP-SNAsaguzaklık. The distribution of pneumatization and septum deviation variations according to gender, lateralization and age groups along with the shape, number and position variations of FSP are shown in the tables. In the presence of pneumatization in CNM, all morphometric distance values are smaller and the values of FSP-BTveruzaklık, FSP-CAsaguzaklık, FSP-MLsaguzaklık, FSP-SNAuzaklık and FSP-SNAsaguzaklık are statistically significantly smaller, while the FSP-SNAaçı value is high. was done. It was found that the morphometric measurement values did not show a statistically significant difference between the types created according to the localization of the FSP according to the location of the attachment point of the CNM and the deviation of the septum. In the literature, there are several studies aiming to determine the localization of FSP with fixed anatomical landmarks in bone structure in different races. FSP shape and variations can make it difficult to locate the FSP during the ligation procedure. The presence of accessory FSP, especially in the form of 7.9% double and 1% triple holes, may cause insufficient ligation. We believe that the data we obtained in our study on this subject, which does not have sufficient studies in the Turkish population, will help to better understand the complex anatomy of this region, especially in the diagnosis and treatment of epistaxis, especially in endoscopic FSP approaches.

Benzer Tezler

  1. Maksiller arter posterior dallarının KIBT görüntülerinde retrospektif olarak değerlendirilmesi

    Evaluation of the posterior branches of the maxillary artery in CBCT images: A retrospective study

    ZEYNEP SERAP BERKTAŞ

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2019

    Diş HekimliğiAnkara Üniversitesi

    Ağız Diş ve Çene Cerrahisi Ana Bilim Dalı

    PROF. DR. CANDAN SEMRA PAKSOY

  2. Foremen Venosum morfolojisinin konik ışınlı bilgisayarlı tomografi görüntülerinde incelenmesi

    Investigation of the Foramen Venosum morphology on cone beam computerized tomography images

    EBRU SENA ÇALIŞIR

    Yüksek Lisans

    Türkçe

    Türkçe

    2023

    AnatomiGaziantep Üniversitesi

    Anatomi Ana Bilim Dalı

    PROF. DR. PİRAYE KERVANCIOĞLU

    DOÇ. DR. ORHAN BEGER

  3. Multidedektör bilgisayarlı tomografi görüntülerinde os hyoideum morfolojisinin yaşa ve cinsiyete göre incelenmesi

    Investigating of the hyoid bone morphology on multidetector computerized tomography images according to the age and gender

    GÜNEŞ BOLATLI

    Yüksek Lisans

    Türkçe

    Türkçe

    2013

    AnatomiSelçuk Üniversitesi

    Anatomi Ana Bilim Dalı

    DOÇ. DR. NADİRE ÜNVER DOĞAN

  4. Türk toplumunda dental implant tedavisi öncesi tetkik amaçlı alınan konik-ışınlı bilgisayarlı tomografi görüntülerinde önemli anatomik yapılar ve varyasyonlarının görülme sıklığı ile tanımlayıcı analizlerinin retrospektif olarak değerlendirilmesi

    Retrospective evaluation of the prevalence of important anatomical structures and variations in cone-beam computed tomography images taken for examination purpose before dental implant treatment in turkish population and descriptive analysis

    MERDAN ALLABERDİYEV

    Doktora

    Türkçe

    Türkçe

    2022

    Diş HekimliğiSağlık Bilimleri Üniversitesi

    Ağız, Diş ve Çene Radyolojisi Ana Bilim Dalı

    DOÇ. DR. İSMAİL HAKAN AVSEVER

  5. Konik ışınlı bilgisayarlı tomografi görüntülerinde derin öğrenme tabanlı kritik anatomik yapıların tespiti

    Deep learning based detection of critical anatomical structures in cone beam computed tomography images

    FURKAN AYDIN

    Yüksek Lisans

    Türkçe

    Türkçe

    2024

    Bilgisayar Mühendisliği Bilimleri-Bilgisayar ve KontrolSamsun Üniversitesi

    Yazılım Mühendisliği Ana Bilim Dalı

    DOÇ. DR. MUAMMER TÜRKOĞLU