Kohlea boyutlarının manyetik rezonans görüntüleme ile 3 boyutlu olarak ölçülmesi güvenilir ve tekrar edilebilir midir?
Measuring 3d cochlea size on MRİ: is it reliable and accurate?
- Tez No: 689357
- Danışmanlar: DR. ÖĞR. ÜYESİ BAŞAK ATALAY, DR. ÖĞR. ÜYESİ NESRİN GÜNDÜZ
- Tez Türü: Tıpta Uzmanlık
- Konular: Radyoloji ve Nükleer Tıp, Kulak Burun ve Boğaz, Radiology and Nuclear Medicine, Otorhinolaryngology (Ear-Nose-Throat)
- Anahtar Kelimeler: Koklea, Koklea hastalıkları, Manyetik rezonans görüntüleme, Tomografi-x ışınlı-bilgisayarlı, Üç boyutlu ölçekleme, İç kulak, Cochlea, Cochlear diseases, Magnetic resonance imaging, Tomography-x ray-computed, Three dimensional scaling, Ear-inner
- Yıl: 2021
- Dil: Türkçe
- Üniversite: İstanbul Medeniyet Üniversitesi
- Enstitü: Göztepe Prof. Dr. Süleyman Yalçın Şehir Hastanesi
- Ana Bilim Dalı: Radyoloji Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Giriş: Bu çalışmanın amacı daha önce bilgisayarlı tomografi ile yapılmış olan kohlea boyut ölçümlerinin manyetik rezonans görüntüleme ile tekrar edilebilirliğini ve güvenilirliğini test etmekti. Gereç ve Yöntem: Çalışma retrospektif, gözlemsel, analitik kurguya sahiptir. Postlingual işitme kayıplı hastaların kohlea boyutlarının bilgisayarlı tomografi (BT) ve manyetik rezonans (MR) görüntülemeleri elde edildi. Bu görüntüler iki gözlemci tarafından 3 boyutlu olarak BT ve MR ile ölçüldü. Yapılan 3 boyutlu kohlea ölçümünün gözlemci-içi tutarlılık ölçümleri ve gözlemciler-arası tutarlılık ölçümleri Sınıf-içi korelasyon katsayısı (ICC) kullanılarak değerlendirildi. Bulgular: Dahil edilen 35 hastanın 21'i (%70'i) erkekti. Katılımcıların yaş ortalaması 39,85±16,60 yıldı. Gözlemci 1 ortalama kohlea boyutlarını BT'de 41.52±2.25 mm ve MR'da 41.44±2.18 mm olarak ölçtü, ortalama fark 0.08 (%95 GA: -0.11 - 0.27) mm olarak bulundu. Gözlemci 2 ortalama kohlea boyutlarını BT'de 41.74±2.69 mm ve MR'da 42.33 ±2.53 mm olarak ölçtü, ortalama fark -0.59 (%95 GA: -1.00 ve -0.20) mm olarak bulundu. Tam tur kohlea uzunluğu için yapılan gözlemciler arası uyum ICC ile BT için 0,90 (%95 GA: 0,84 – 0,94) iken MR'da ICC 0,69 (%95 GA: 0,46 – 0,82) olarak bulundu. Sonuç: Bu çalışmanın sonuçları BT ile yapılan 3 boyutlu kohlea boyut ölçümlerinin gözlemciler-içi ve gözlemciler-arası uyumunun mükemmel olduğunu gösterdi. MR ile yapılan ölçümlerde gözlemciler-içi tekrar edilebilirlik özellikle tam tur kohlea uzunluğu için“iyi”ve“mükemmelken”, gözlemciler-arası uyum orta düzeyde kaldı. Bu sonuç BT görüntüleme kullanılan 3 boyutlu kohlea ölçüm yönteminin referans method olduğunu bir kez daha teyit etmiş oldu.
Özet (Çeviri)
Introduction: This study aimed to test the repeatability and reliability of cochlea lateral wall length (LWL) using 3D magnetic resonance imaging. Materials and Methods: This study was retrospective and observational. Two observers measured the cochlea LWL of patients with post-lingual hearing loss using computed tomography (CT) and magnetic resonance imaging (MRI). Intra-class correlation coefficient (ICC) was used to test the intra and inter-observer agreement of the 3D cochlea measurements. Results: Of the 35 patients included, 21 (70%) were male. The mean age of the participants was 39.85 ± 16.60 years. Observer 1 measured the mean LWL as 41.52 ± 2.25 mm on CT, and 41.44 ± 2.18 mm on MR, and the mean difference was found to be 0.08 (95% CI: -0.11 - 0.27) mm. Observer 2 measured the mean LWL as 41.74 ± 2.69 mm on CT, and 42.33 ± 2.53 mm on MR, and the mean difference was found to be -0.59 (95% CI: -1.00 and -0.20) mm. In the inter-observer agreement for LWL was 0.90 (95% CI: 0.84 - 0.94) for CT, while ICC was 0.69 (95% CI: 0.46 - 0.82) in MRI was found. Conclusion: This study showed that the 3D measurements of cochlea made by CT showed“excellent”intra-observer and interobserver agreement. Intra-observer agreement for LWL measurements by MRI, was“good”to“excellent,”while the interobserver agreement was“moderate.”These results confirmed that the 3D cochlea measurement method using CT imaging is the reference method.
Benzer Tezler
- Koklear hipoplazili hastalarda kokleanın boyutlarının temporal kemik bilgisayarlı tomografi ve temporal manyetik rezonans görüntüleme kullanılarak ölçülmesi ve koklear implant seçimine etkileri
Measurements of cochlear dimensions in cochlear hypoplasia using temporal bone computerized tomography and temporal magnetic resonance imaging and effects of cochlear implant selection
GÖZDE PAMUK
Tıpta Uzmanlık
Türkçe
2018
Kulak Burun ve BoğazHacettepe ÜniversitesiKulak Burun Boğaz ve Baş-Boyun Cerrahisi Ana Bilim Dalı
PROF. DR. LEVENT SENNAROĞLU
- Koklear apertür ve internal akustik kanal ile vestibülokoklear sinir varlığı arasındaki ilişkinin araştırılması
Investigation of the bony cochlear nerve canal and internal auditory meatus and their effect on the vestibulocochlear nerve
EMEL TAHİR
Tıpta Uzmanlık
Türkçe
2014
Kulak Burun ve BoğazHacettepe ÜniversitesiKulak Burun Boğaz Hastalıkları Ana Bilim Dalı
PROF. DR. LEVENT SENNAROĞLU
- İç kulak malformasyonlu hastalarda anteroposterior grafi ile açısal insersiyon derinliği ölçümü, koklea boyutları ve elektrod uzunluğu ile ilişkisinin incelenmesi
Angular Insertion Depth Measurement on Anteroposterior Skull X-ray in Patients with Inner Ear Anomaly, Investigation of Its Relationship with Cochlea Dimensions and Electrode Length
BURÇAY TELLİOĞLU
Tıpta Uzmanlık
Türkçe
2023
Kulak Burun ve BoğazHacettepe ÜniversitesiKulak Burun Boğaz Hastalıkları Ana Bilim Dalı
PROF. DR. LEVENT SENNAROĞLU
- Temporalty in architecture
Mimaride yaşantı kavramı
ECE CEYLAN BABA
Yüksek Lisans
İngilizce
2006
FelsefeYeditepe ÜniversitesiMimarlık Ana Bilim Dalı
Y.DOÇ.DR. MURAT ŞAHİN
ÖĞR.GÖR. ARMAN GÜRAN
- Figür fon ilişkisindeki gerilim açısından Gülveli Kaya'nın resimleri
Gülveli Kaya's paintings in terms of tension in the relation between figure and found
ÖZLEM ÖZDEN
Yüksek Lisans
Türkçe
2019
Güzel SanatlarHatay Mustafa Kemal ÜniversitesiResim Ana Sanat Dalı
DOÇ. CÜNEYT KURT