Peri-implant doku sağlığı üzerinde keratinize mukoza genişliğinin etkisinin değerlendirilmesi
Evaluation of the effect of keratinized mucosa width on peri-implant tissue HEALTH
- Tez No: 694289
- Danışmanlar: PROF. DR. BÜLEND İNANÇ
- Tez Türü: Diş Hekimliği Uzmanlık
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Keratinize mukoza, Dental implant, Peri-implant hastalıklar, Ağız mukozası, Dental implantasyon, Dental implantlar, Keratinler, Periimplantitis, Keratinized mucosa, Dental implant, Peri-implant diseases, Mouth mucosa, Dental implantation, Dental implants, Keratins, Periimplantitis
- Yıl: 2021
- Dil: Türkçe
- Üniversite: Trakya Üniversitesi
- Enstitü: Diş Hekimliği Fakültesi
- Ana Bilim Dalı: Periodontoloji Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Bu kesitsel araştırmanın amacı, KMG'nin peri-implant doku sağlığı üzerindeki etkisini değerlendirmektir. Çalışmaya yaşları 22-75 arasında değişen 196 hasta ve 683 dental implant dahil edildi. Tüm implantların CD, GI, SK, GI-SK, mSKI, PI, MÇ, süpürasyon, KKK, KMG ölçümleri kaydedildi. İmplantlar; yetersiz KMG olan (<2 mm) ve yeterli KMG olan (≥2 mm) implantlar olarak kategorize edildi. Klinik ve radyolojik veriler, Mann-Whitney U, Kruskal Wallis, Ki- Kare ve Pearson korelasyon testi kullanılarak istatistiksel olarak analiz edildi. Peri-implant parametreler ile KMG arasındaki potansiyel ilişkileri test etmek için tek değişkenli regresyon analizi yapıldı. 459 implantta (% 67,2) yeterli KMG olduğu, 224 implantta (%32,8) yetersiz KMG bulundu. KMG CD ile pozitif, diğer parametreler ile (hasta seviyesinde mSKI hariç) negatif şekilde korele olduğu tespit edildi (p<0.05). KMG <2 mm olan implantlarda daha az CD saptandı (p<0,05). GI, SK, GI-SK, PI, MÇ, KKK değerleri KMG <2 mm olan grupta daha yüksek bulundu (p>0,05). Süpürasyon varlığında ve mSKI'nde gruplar arası fark bulunmadı (p>0,05). Hasta seviyesi değerlendirmelerde sağlıklı implantların KMG ≥2 mm olan grupta daha fazla olduğu tespit edildi (p<0,05). KMG'nin peri-implant mukozitis oluşması üzerinde etkisi bulunmazken (p>0,05), peri-implantitis oluşması için risk faktörü olduğu bulundu (p<0,05). Keratinize mukoza eksikliği peri-implant doku inflamasyonu, MÇ ve KKK'yla ilişkili bulunmuştur. Peri-implant doku sağlığının sürdürülebilmesi için keratinize mukoza varlığı şart olmamakla birlikte, en az 2 mm KMG bulunması önerilmektedir.
Özet (Çeviri)
The aim of this cross-sectional study was to evaluate the effect of KMW on peri-implant tissue health. A total of 196 patients aged between 22-75 and 683 dental implants were included in the study. PD, GI, BOP, GI-BOP, mSBI, PI, MR, suppuration, CBL, KMW measurements of all implants were recorded. Implants; were categorized as implants with inadequate KMW (<2 mm) and implants with adequate KMW (≥2 mm). Clinical and radiological data were statistically analyzed using Mann-Whitney U, Kruskal Wallis, Chi-Square and Pearson correlation tests. Univariate regression analysis was performed to test for potential associations between peri-implant parameters and KMW. Adequate KMW was found in 459 implants (67.2%), and inadequate KMW was found in 224 implants (32.8%). KMW was positively correlated with PD and negatively correlated with other parameters (except for mSBI at patient level) (p<0.05). Less PD was detected in implants with KMW <2 mm (p<0.05). GI, BOP, GI-BOP, PI, MR, CBL values were found to be higher in the group with KMW <2 mm (p>0.05). There was no significant difference between the groups in the presence of suppuration and mSBI (p>0.05). In patient-level evaluations, it was determined that healthy implants were more common in the group with KMW ≥2 mm (p<0.05). While KMW had no effect on the occurrence of peri implant mucositis (p>0.05), it was found to be a risk factor for the occurrence of peri-implantitis (p<0.05). Keratinized mucosa deficiency was found to be correlated with peri-implant tissue inflammation, MR and CBL. Although the presence of keratinized mucosa isn't necessary to maintain peri-implant tissue health, it is recommended to have at least 2 mm KMW.
Benzer Tezler
- Diş Hekimliği Fakültesinde monoblok dental implant uygulanan hastaların demografik, klinik, radyolojik olarak değerlendirilmesi
Demographic, clinical and radiological evaluation of patients treated with monoblock dental implants in the Faculty of Dentistry
ÖMER FARUK ALP
Diş Hekimliği Uzmanlık
Türkçe
2025
Eskişehir Osmangazi ÜniversitesiPeriodontoloji Ana Bilim Dalı
Yükleniyor...
- İmplant çevresi gingival fenotipin peri-implant doku sağlığı üzerine etkisinin değerlendirilmesi
Clinical evaluation of the effect of implant enviroment gingival phenotype on peri-implant tissue health
MERVE TUR
- Ege bölgesi keçi liflerinin bazı önemli fiziksel, kimyasal özellikleri ve değerlendirme imkanları
Başlık çevirisi yok
NİLÜFER ERDEM
- Bir pamuk iplikhanesinde fiili çalışma metodlarının incelenmesi ve mevcut işlemlerin standart sürelerinin saptanması
Başlık çevirisi yok
MÜRŞİDE KESEROĞLU
- Çukurova bölgesinde biyoklimatik veriler kullanılarak açık ve yeşil alan sistemlerinin belirlenmesi ilkeleri üzerinde bir araştırma
A research on the determination of the principles in open and green spaces systems by using the bioclimatic data in Çukurova region
MEHMET FARUK ALTUNKASA