Bir alışveriş merkezi binasında kullanılan iklimlendirme sistemleri için potansiyel enerji etkin kullanım ve enerji geri kazanım yöntemlerinin incelenmesi
Investigation of potential energy-efficient use and energy recovery techniques for air conditioning systems used in a shopping mall building
- Tez No: 730784
- Danışmanlar: DOÇ. DR. DOĞAN ERDEMİR
- Tez Türü: Yüksek Lisans
- Konular: Makine Mühendisliği, Mechanical Engineering
- Anahtar Kelimeler: Buzda enerji depolama, Evaporatif soğutma, Atık sudan ısı geri kazanımı, Isı pompası, Enerji etkin kullanım, Ice thermal energy storage, Evaporative cooling, Heat of waste water, Heat pump
- Yıl: 2022
- Dil: Türkçe
- Üniversite: Erciyes Üniversitesi
- Enstitü: Fen Bilimleri Enstitüsü
- Ana Bilim Dalı: Makine Mühendisliği Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: 131
Özet
Bu tez çalışmasında Ankara bulunan Atakule Alışveriş Merkezi'nin iklimlendirme sistemleri için kullanılabilecek potansiyel yöntemler termodinamik ve ekonomik açıdan değerlendirilmiştir. Halihazırda incelenen mahalde ısıtma ve soğutma sistemlerinde su kaynaklı ısı pompası kullanılmaktadır. Statik ısıtma ise doğalgaz yakıtlı kazanlarla sağlanmaktadır. Geleneksel cihazlar göz önünde bulundurulduğu zaman su kaynaklı ısı pompaları oldukça verimli cihazlardır. Bu tez çalışmasında, mahalde kullanılan bu cihazların daha verimli kullanmanın yolları araştırılmıştır. Bu kapsamda, soğutma sistemlerinin etkinliğini arttırmak için soğutma sistemlerine buzda enerji depolama ve taze hava sistemi için evaporatif soğutma entegre edilmiştir. Ayrıca, lavabo giderlerinde oluşan atık sıcak suyun geri kazanılması ve ısıtma sistemine dahil edilmiştir. Yapılan termodinamik analizler sonucunda, buzda enerji depolama entegre soğutma sisteminin COP'si 4,26 olarak bulurken, su kaynaklı ısı pompasının COP değeri 3,62 olarak bulunmuştur. Buzda enerji depolama sistemin verimini %17 arttırmıştır. Buzda enerji depolama sistemi soğutma için kullanılan elektriğin maliyetinde %29,4 düşüş sağlamıştır. Sistemin amortisman süresi 4,2 yıl olarak hesaplanmıştır. 10 yılın sonunda ise 2,1 milyon TL'den fazla tasarruf sağlayacağı görülmüştür. Taze havanın soğutma yükünü azaltmak için kullanılan evaporatif soğutma yöntemi ise yıllık otuz bin TL'den fazla tasarruf sağlayacağı görülmüştür. Sağlanan tasarruf elektrik tüketim maliyetlerinde %6,8 azalma potansiyeli olduğunu göstermiştir. Buzda enerji depolama ve evaporatif soğutma birlikte kullanıldığı zaman toplamda elektrik maliyetlerinde %36,2 düşüş olacağı görülmüştür. Lavabo giderlerinde oluşan atık suyun ısısının geri kazanılması ve ısıtma sistemine dahil edilmesi durumunda yıllık 28 bin TL'lik bir tasarruf olacağı ve bunun ısıtma maliyetlerini %40 düşüreceği belirlenmiştir. Bu sistemin amortisman süresi 1,86 yıl olarak hesaplanmıştır.
Özet (Çeviri)
A water source heat pump was used in the heating and cooling systems of Atakule AVM. Static heating is provided by boilers. Heat pumps are very efficient devices in terms of electricity consumption. Looking for ways to make these devices more efficient, we coupled energy storage in ice to rooftop devices and cooling the fresh air with evaporative method. In addition, we used the method of heating the mains water by using the heat of the waste water generated in the sink drains. As a result of the thermodynamic analysis, the COP of the integrated cooling system with ice storage was found to be 4.30, while the COP value of the water source heat pump was found to be 3.20. Ice storage systems increased the efficiency by 10%. As a result of the studies, when the energy storage system in ice was used, there was a %29,4 reduction in the electricity bill. The amortization period is calculated as 4.2 years. Profit from electricity bills in 10 years has been calculated as TL 2.095970,553. When the fresh air cooling system with the evaporative method is used, the profit obtained in the electricity bill is calculated as 30490 TL per year. Resulting in a 6.8% reduction in the bill. When the combination of energy storage in ice and evaporative cooling of fresh air was used, there was a %36,2 reduction in the electricity bill. When the method of heating the mains water using the heat of the waste water generated in the sink expenses is used, the profit obtained is calculated as 28.000 TL per year, resulting in a 40% reduction in natural gas consumption. The amortization period is calculated as 1.86 years.
Benzer Tezler
- Theoretical modeling of the energy efficiency of a shopping mall
Bir alışveriş merkezinin enerji verimliliğinin teorik modellenmesi
HAMZA ABUALESS
Yüksek Lisans
İngilizce
2023
EnerjiAtatürk ÜniversitesiMakine Mühendisliği Ana Bilim Dalı
PROF. DR. KADİR BİLEN
- Alışveriş merkezlerindeki mağazalarda parametrik tavan ve aydınlatma tasarımı
Parametric ceiling and lighting design in shops in shopping centers
ŞEYMA YILDIRIM ALTINDAŞ
Yüksek Lisans
Türkçe
2021
MimarlıkKTO Karatay ÜniversitesiMimarlık Ana Bilim Dalı
DR. ÖĞR. ÜYESİ AYŞEGÜL TERECİ
- Machine learning-based energy consumption forecastingfor stores in a shopping center - A case study
Alışveriş merkezindeki dükkânların enerji tüketimininmakine öğrenmesiyle tahmini - Vaka çalışması
NADIA AHBAB
Yüksek Lisans
İngilizce
2023
Enerjiİstanbul Teknik ÜniversitesiEnerji Bilim ve Teknoloji Ana Bilim Dalı
ÖĞR. GÖR. MUSTAFA BERKER YURTSEVEN
- Türkiye inşaat sektöründe karmaşık projelerde çevik proje yönetim yaklaşımı ve scrum metodu
Agile project management approach and scrum method in complex projects in the Turkiye construction industry
RABİA NUR EKİZOĞLU
Yüksek Lisans
Türkçe
2024
MimarlıkErciyes ÜniversitesiMimarlık Ana Bilim Dalı
PROF. DR. ZÜBEYDE ÖZLEM PARLAK BİÇER
- Alışveriş merkezlerindeki mağazaların satış yoğunluğunun mekansal dizim yöntemiyle irdelenmesi
The examination ofsales density of stores in shopping malls by space syntax method
ELİF TAVUKÇUOĞLU
Yüksek Lisans
Türkçe
2017
Mimarlıkİstanbul Teknik ÜniversitesiMimarlık Ana Bilim Dalı
PROF. DR. ALPER ÜNLÜ