Geri Dön

Küçük alan radyoterapi tedavisinde kullanılan yüksek enerjili ışınların su ortamındaki doz dağılımlarının incelenmesi

Investigation of dose distributions of high energy beams used in small field radiotherapy treatment in water medium

  1. Tez No: 750534
  2. Yazar: GÖRKEM AYDOĞDU
  3. Danışmanlar: DOÇ. DR. GÜLTEKİN YEĞİN
  4. Tez Türü: Doktora
  5. Konular: Fizik ve Fizik Mühendisliği, Physics and Physics Engineering
  6. Anahtar Kelimeler: Boyut etkisi, Monte Carlo Yöntemi, Radyometri, Radyoterapi, Size effect, Monte Carlo Method, Radiometry, Radiotherapy
  7. Yıl: 2022
  8. Dil: Türkçe
  9. Üniversite: Manisa Celal Bayar Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Fizik Ana Bilim Dalı
  12. Bilim Dalı: Nükleer Fizik Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmanın amacı, küçük alan radyoterapi uygulamalarında, tedavi planlama sistemi (TPS)' nde Monte Carlo tabanlı doz hesaplama algoritmalarının daha doğru doz tahminlemesi yapabilmelerine yönelik olarak voksel boyut etkilerinin araştırılmasıdır. Bu tez çalışmasında, cilt dokusunda ve deri altındaki yüzeye yakın bölgelerde doz dağılımları hesaplanarak voksel boyut etkileri incelendi. Tedavi alanı boyutu, ortam materyali ve foton enerjisi gibi fiziksel parametreler TPS' deki durumlar dikkate alınarak belirlendi. Doz hesaplamaları üç ayrı aşamada gerçekleştirildi. Bütün aşamalarda, EGSnrc Monte Carlo kodu tabanlı DOSXYZnrc kullanıcı kodu kullanıldı ve hasta vücudu 30x30x5 cm3 hacimli homojen bir su fantomu olarak kabul edildi. Doz dağılımları, farklı tedavi alanı boyutları, voksel boyutları ve foton enerjileri için z=1.0 cm' ye kadar farklı derinliklerde, yatayda ve X-ışını gelme doğrultusundaki düzlemde değişik senaryolarda ayrı ayrı hesaplandı. Birinci aşamada elde edilen sonuçlar değerlendirildiğinde, 1 MeV foton enerjisinde ideal voksel kenar uzunluk değerinin, alan boyutuna ve derinliğe bağlı olarak dikkate değer ölçüde değiştiği ortaya konuldu. İkinci aşamada 0.5x0.5 cm2 ve 3x3 cm2 tedavi alanlarında ve farklı foton enerjileri (2-10 MeV) için 1.0 cm derinliğe kadar farklı noktalardaki doz değerleri hesaplandı. İdeal voksel büyüklüklerinin, alan boyutuna, gelen foton enerjisine ve derinliğe bağlı olarak önemli şekilde değiştiği bulundu. Üçüncü aşamada 4 MV' lik bir hızlandırıcı başlığından çıkan X-ışını spektrumu için 0.5x0.5 cm2 ve 3x3 cm2 tedavi alanlarında doz hesaplamaları ayrı ayrı gerçekleştirildi. Monoenerjitik ve spektrum foton kaynakları kullanılarak elde edilen doz değerlerinin farklı olmasına rağmen ideal voksel kenar uzunluk değerlerinin birbirleriyle aynı olduğu gösterildi. Monte Carlo tekniği kullanılarak yapılan tüm hesaplamalarda ve her bir tedavi alanı için seçilen enerji ve geometri koşullarında 0.1 cm derinliğe kadar 0.01 cm voksel kenar uzunluk değerinin kullanılabilecek yatay düzlemdeki ideal voksel boyutu olduğu sonucuna varıldı. Küçük alanlar için güvenle kullanılabilecek voksel kenar uzunluk değerinin, hem spektrum hem de monoenerjitik foton kaynakları için, gelen foton enerjisi, tedavi alanın büyüklüğü ve derinlik değerlerindeki artışa bağlı olarak, daha büyük uzunluklarda seçilebileceği gösterildi. Geometri koşullarına göre tedavi alanı genişliği, gelen foton enerjisi ve derinliğe bağlı ideal voksel kenar uzunluk değerleri tablolar halinde sunuldu. Bu tablolarda detaylı olarak yer alan verilerin klinik kullanımda dikkate alınmaları halinde doz değerlerinin daha kesin bir şekilde hesaplanabileceği ve buna bağlı olarak da tedavi sonrasında hastalarda ortaya çıkabilecek hayati yan etkilerin önlenmesinde önemli katkı sağlanabileceği sonucuna varıldı.

Özet (Çeviri)

The aim of this study is to investigate the voxel size effects of Monte Carlo-based dose calculation algorithms in small field radiotherapy applications and treatment planning system (TPS) for more accurate dose estimation. In this thesis study, voxel size effects were investigated by calculating dose distributions in skin tissue and subcutaneous field close to the surface. Physical parameters such as treatment field size, media material and photon energy were determined by considering the conditions in their TPS. Dose calculations were carried out in three separate stages. In all stages, the EGSnrc Monte Carlo code-based DOSXYZnrc user code was used and the patient's body was considered as a homogeneous water phantom with a volume of 30x30x5 cm3. Dose distributions were calculated separately in different scenarios for different treatment field sizes, voxel sizes and photon energies at different depths up to z=1.0 cm, horizontally and in the plane in the X-ray incident direction. When the results obtained in the first stage were evaluated, it was revealed that the ideal voxel edge length value at 1 MeV photon energy varies considerably depending on the field size and depth. In the second stage, dose values were calculated in 0.5x0.5 cm2 and 3x3 cm2 treatment areas and at different points up to 1.0 cm depth for different photon energies (2-10 MeV). Ideal voxel sizes were found to vary significantly depending on field size, incident photon energy and depth. In the third stage, dose calculations were carried out separately for the X-ray spectrum emanating from a 4 MV accelerator head in 0.5x0.5 cm2 and 3x3 cm2 treatment areas. Although the dose values obtained using monoenergetic and spectrum photon sources are different, the ideal voxel edge length values were shown to be the same. It was concluded that 0.01 cm voxel edge length value up to 0.1 cm depth is the ideal voxel size in the horizontal plane that can be used in all calculations using the Monte Carlo technique and under the selected energy and geometry conditions for each treatment area. It has been shown that the voxel edge length value that can be used safely for small field can be selected for larger lengths for both spectrum and monoenergetic photon sources, depending on the increase in the incident photon energy, the size of the treated area and the depth values. According to the geometry conditions, the treatment area width, incident photon energy and ideal voxel edge length values depending on the depth were presented in tables. It was concluded that if the data in these tables in detail are taken into account in clinical use, dose values can be calculated more precisely, and accordingly, a significant contribution can be made to the prevention of vital side effects that may occur in patients after treatment.

Benzer Tezler

  1. Landsat uydusu aracılığı ile elde edilen görüntülerin sınıflandırılmaları ve bunlara ilişkin bilgisayar programlarının hazırlanması

    Başlık çevirisi yok

    G. FERZAN KÜÇÜKA

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Bilgisayar Bilimleri ve Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  2. Dokuma kumaşlarda örgü tipinin ham kumaşın boyutları ve geometrik özellikleri üzerindeki etkilerinin araştırılması

    Başlık çevirisi yok

    EMEL ÖNDER

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Tekstil Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  3. Çocuklarda akut stres hiperglisemisinde hormonal değişikliklerin ve kısa süreli prognozun incelenmesi

    Başlık çevirisi yok

    AYGÜN DİNDAR

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1987

    İstanbul Üniversitesi

    Çocuk Sağlığı ve Hastalıkları Hemşireliği Ana Bilim Dalı

    Yükleniyor...

  4. İki katlı pamuk ipliklerinden dokunan kumaşlarda örgüye bağlı olarak maksimum atkı sıklığının değişimi üzerinde bir araştırma

    Başlık çevirisi yok

    MELTEM ASLI NARTER

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Tekstil Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  5. Manisa yöresinde domateste anlaşmalı tarım ve karşılaşılan sorunlar

    Başlık çevirisi yok

    OSMAN MURAT KOÇTÜRK

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Tarım Ekonomisi Ana Bilim Dalı

    Yükleniyor...