Lif donatılı çimento malzemeler ile güçlendirilmiş konsol betonarme kirişlerin yapısal davranışının incelenmesi
Investigation of the structural behavior of concrete beams strengthened with fiber reinforced cement materials
- Tez No: 764293
- Danışmanlar: DOÇ. DR. ALPTUĞ ÜNAL, DOÇ. DR. OĞUZHAN ÖZTÜRK
- Tez Türü: Yüksek Lisans
- Konular: İnşaat Mühendisliği, Civil Engineering
- Anahtar Kelimeler: Belirtilmemiş.
- Yıl: 2022
- Dil: Türkçe
- Üniversite: Konya Teknik Üniversitesi
- Enstitü: Lisansüstü Eğitim Enstitüsü
- Ana Bilim Dalı: İnşaat Mühendisliği Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: 149
Özet
Ülkemizde çok sayıda binada, mimari estetik kaygı veya kat alanının büyütülmesi amacıyla, yapı taşıyıcı sisteminde çeşitli düzensizlikler yer almaktadır. Binalarda gözlenen en yaygın kusurlardan bir tanesi yapı konsollarıdır. Yapılan gözlemler sonucunda, yapılardaki konsolların kolon kiriş birleşim bölgesindeki problemler özellikle de deprem bölgesindeki binalarda elemanların taşıma kapasitelerine etkisi ciddi risk oluşturmaktadır. Söz konusu durumlar ülkemizde çok sık karşılaşılmasına rağmen bugüne kadar kapsamlı bir şekilde ele alınmamıştır. Bu sebeple konsol kiriş oluşumunda ortaya çıkan sorunların önüne hızlı ve etkili bir biçimde geçmek, gerekli güçlendirme şeklini incelemek adına bu tez çalışması yapılmıştır. Kolon kiriş birleşim bölgesindeki problemler ele alınıp ona göre bir güçlendirme yöntemi önerilmiştir. Bu hedef doğrultusunda ülkemizde ve dünyada giderek daha çok araştırmaya konu olan lif donatılı beton ile konsol kirişlerin güçlendirme çalışması yapılmıştır. Bu amaçla biri referans olmak üzere toplamda 9 adet konsol kiriş numunesi üretilmiş ve depremi benzeştiren tersinir tekrarlanır yükler altında test edilmiştir. Deneylerde kiriş mesnet bölgesine ve kiriş açıklığı boyunca lif donatılı beton ile güçlendirilmiş paneller kullanılmıştır. Güçlendirmede kullanılan lif donatılı beton paneller epoksi ve ankraj çubuklarıyla numunelere montajlanmıştır. Deneyde konsol kirişe kiriş uç noktasından yükleme yapılmıştır. Deney elemanlarına tersinir tekrarlanır yatay yük verilerek kolon-kiriş birleşim bölgesindeki hasarlar incelenmiştir. Yapılan deneylerin sonuçlarının daha iyi yorumlanabilmesi amacıyla deney sırasında alınan yük ve deplasman değerleri kullanılarak; yük deplasman grafiği, zarf eğrisi, kümülatif tüketilen enerji grafiği, rijitlik grafiği çizilmiş ve süneklik değeri hesaplanmıştır. Ek olarak deney numunelerinin karşılaştırmalı değerlendirmesi yapılmıştır. RB-LDB2-LEW deney elemanı en yüksek yük taşıma kapasitesine sahiptir.
Özet (Çeviri)
In our country, many buildings are usually placed on console overhangs after the ground floor in order to enlarge the floor area. As a result of the observations, it has been observed that in many of these buildings, due to the deflection of the cantilever beams, large cracks have formed on the walls resting on the beams over time Although these situations are frequently encountered in our country, they have not been dealt with comprehensively until today. For this reason, this thesis was carried out in order to prevent the problems that arise in the formation of cantilever beams quickly and effectively and to make the necessary reinforcement. In line with this goal, reinforcement of cantilever beams was carried out with LDB (Fiber Reinforced Concrete), which is the subject of more and more researches in our country and in the world. For this purpose, a total of 9 cantilever beam samples, one of which is a reference, were produced and tested under reversible and repeated loads simulating earthquakes. LDB reinforced panels were used in the beam support area and along the beam span in the experiments. The LDB panels used in the reinforcement were mounted on the samples with epoxy and anchor rods. In the experiment, the cantilever beam was loaded from the beam end point. Damages in the column-beam junction in case of earthquake were investigated. In order to better interpret the results of the experiments, by using the load and displacement values taken during the experiment; load displacement graph, envelope curve, cumulative consumed energy graph, the stiffness graph was drawn and the ductility value was calculated. In addition, a comparative evaluation of the test samples was made. The RB-LDB2-LEW test element has the highest load carrying capacity.
Benzer Tezler
- Standart altı betonarme kolonların yenilikçi malzemeler kullanılarak deprem performansının iyileştirilmesi
Improvement of earthquake performance of sub-standard reinforced concrete columns using innovative materials
MUHSİN CAN LÜLECİ
Yüksek Lisans
Türkçe
2022
Kamu Yönetimiİstanbul Teknik Üniversitesiİnşaat Mühendisliği Ana Bilim Dalı
PROF. DR. ALPER İLKİ
- Düşük dayanımlı beton panellerin ileri teknoloji malzemeler ile güçlendirilmesi
Strengthening of low srength concrete panels using innovative materials
YASİN CANDAN
Yüksek Lisans
Türkçe
2007
İnşaat Mühendisliğiİstanbul Teknik Üniversitesiİnşaat Mühendisliği Ana Bilim Dalı
DOÇ.DR. ALPER İLKİ
- Betonarme kolonların deprem performansının tekstil donatılı / donatısız cam lifli püskürtme harçla iyileştirilmesi
Improvement of seismic performance of reinforced concrete columns using glass fiber reinforced sprayed mortar with / without textile reinforcement
ALİ OSMAN ATEŞ
Doktora
Türkçe
2022
Deprem Mühendisliğiİstanbul Teknik Üniversitesiİnşaat Mühendisliği Ana Bilim Dalı
PROF. DR. ALPER İLKİ
- Tensile strength of cement-fiber treated sands
Çimento ve fiber katkılı kumların çekmede dayanımı
HAMED FEIZOLLAHZADEH ARDABILI
Yüksek Lisans
İngilizce
2017
İnşaat Mühendisliğiİstanbul Teknik Üniversitesiİnşaat Mühendisliği Ana Bilim Dalı
PROF. DR. AYFER ERKEN
- Dayanım ve dayanıklılık açısından yüksek performanslı çimento esaslı tabakalı kompozitlerin geliştirilmesi
Development of high performance cementitious laminated composites in terms of high strength and high durabilty
ESMA GİZEM DAŞKIRAN
Doktora
Türkçe
2018
İnşaat Mühendisliğiİstanbul Teknik Üniversitesiİnşaat Mühendisliği Ana Bilim Dalı
DOÇ. DR. MUSTAFA GENÇOĞLU