Kedilerin vücut sıcaklıklarının ölçümünde kullanılan farklı ölçüm metotlarının karşılaştırılması

Comparison of different body temperature measurement methods in cats

  1. Tez No: 769038
  2. Yazar: MEHMET NURİ ÖZTÜRK
  3. Danışmanlar: DR. ÖĞR. ÜYESİ MÜMİN GÖKHAN ŞENOCAK
  4. Tez Türü: Yüksek Lisans
  5. Konular: Veteriner Hekimliği, Veterinary Medicine
  6. Anahtar Kelimeler: Axillar sıcaklık, temassız kızılötesi termometresi, termal kamera, timpanik membran termometresi, vücut sıcaklığı, Aksilla, Kediler, Sıcaklık ölçme, Termometreler, Timpanik membran, Veteriner hekimlik, Veterinerlik, Axillar temperature, non-contact infrared thermometer, thermal camera, tympanic membrane thermometer, body temperature, Axilla, Cats, Temperature measurement, Thermometers, Tympanic membrane, Veterinary medicine, Veterinary
  7. Yıl: 2023
  8. Dil: Türkçe
  9. Üniversite: Atatürk Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Veterinerlik Cerrahisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Amaç: Kedilerde üç farklı temassız kızılötesi sıcaklık ölçüm cihazı (NCT1, NCT2 ve NCT3), iki farklı termal kamera (Cat, Flexcam), iki farklı timpanik membran termometresi (HT ve CT) ve dijital termometre kullanılarak; oküler (Oc), oral (Or), perianal (PA), interdigital (Int), Axillar (AT) ve timpanik membran (TM) bölgelerinden elde edilen vücut sıcaklığının dijital termometreyle yapılan rektal sıcaklık ölçümüyle (RT) olan uyumun belirlenmesi bu çalışmanın amacıdır. Materyal ve Metot: Dahil edilme kriterini taşıyan 30 kedinin RT, PA, Oc, Or, TM, AT, sıcaklıkları DT, HT, CR, NCT1, NCT2, NCT3, Cat, Flexcam cihazlarıyla aynı anda ölçülerek kaydedildi. RT sıcaklığı referans değer kabul edilerek, diğer cihazlar ve ölçüm noktalarından elde edilen sıcaklık değerlerinin RT ile uyumu Passing Bablok ve Bland Altman analiziyle karşılaştırıldı. Bulgular: RT ölçümüne uyumluluk gösteren yöntemlerin sırasıyla; Dijital AT, NCT3 Oc, NCT3 PA, NCT3 Or, NCT2 Oc ve NCT2 Or olduğu belirlendi. Cat, Flexcam ve NCT1 cihazıyla yapılan tüm ölçümlerin yanında NCT2 AT, NCT2 Int, NCT2 PA, NCT3 AT, NCT3 Int, Flexcam PA, Flexcam Oc, HT ve CT yöntemlerinin RT ile uyumlu olmadığı belirlendi. Dijital AT'ye 0.27 ± 0.63 °C, NCT3 Oc'ye 2.68 ± 0.71 °C ve NCT3 PA'ya 2.56 ± 0.85 °C eklenerek RT'nin yorumlanabileceği belirlendi. Sonuç: Dijital termometreyle yapılan axillar ölçüm yönteminden sonra rektal sıcaklıkla en fazla uyum gösteren vücut sıcaklığı ölçüm yöntemleri sırasıyla, NCT3 cihazıyla yapılan oküler, perianal ve oral ölçümleriyle, NCT2 cihazıyla yapılan oküler ve oral ölçümleridir. Termal kameralar ve timpanik yöntemlerle yapılan vücut sıcaklığı ölçümleri rektal sıcaklıkla uyum göstermemektedir.

Özet (Çeviri)

Aim: This study aims to determine the compatibility between digital rectal temperature (RT) and temperatures obtained from ocular (Oc), oral (Or), perianal (PA), interdigital (Int), Axillar (AT), and tympanic membrane (TM) regions by using three different non-contact infrared temperature measuring devices (NCT1, NCT2, and NCT3), two different thermal cameras (Cat, Flexcam), two different tympanic membrane thermometers (HT and CT), and digital thermometer in cats. Material and Method: The RT, PA, Oc, Or, TM, AT temperatures of 30 cats were measured with DT, HT, CR, NCT1, NCT2, NCT3, Cat, and Flexcam devices. RT temperature was accepted as a reference value, and the compatibility of temperatures obtained from other devices was compared with RT using Passing-Bablok and Bland-Altman analyses. Result: The methods that comply with RT measurement are; digital AT, NCT3 Oc, NCT3 PA, NCT3 Or, NCT2 Oc, and NCT2 Or were determined. NCT1, NCT2 AT, NCT2 Int, NCT2 PA, NCT3 AT, NCT3 Int, Flexcam PA, Flexcam Oc, HT, CT, and all samples collected by both thermal cameras were found to be incompatible with RT. It was determined that RT could be interpreted by adding 0.27 ± 0.63 °C to digital AT, 2.68 ± 0.71 °C to NCT3 Oc, and 2.56 ± 0.85 °C to NCT3 PA. Conclusion: Axillar digital thermometry is the most compatible method with rectal temperature. Besides, the ocular, perianal, and oral measurements with the NCT3 device and the ocular and oral measurements with the NCT2 device are compatible methods. Body temperature measurements made by thermal cameras and tympanic methods do not comply with RT.

Benzer Tezler

  1. Ege bölgesi keçi liflerinin bazı önemli fiziksel, kimyasal özellikleri ve değerlendirme imkanları

    Başlık çevirisi yok

    NİLÜFER ERDEM

    Doktora

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Tekstil Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  2. Mammografi ve ultrasonografinin meme kanseri tanısında yeri

    Başlık çevirisi yok

    CEBBAR ÇALIŞKAN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1986

    Gata

    Genel Cerrahi Ana Bilim Dalı

    Yükleniyor...

  3. Böceklerde ışık meydana getirme

    Light emitting process in insects

    HALİL DÜNDAR

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Ege Üniversitesi

    Bitki Koruma Ana Bilim Dalı

    Yükleniyor...

  4. Yahya Kemal'de bedii tefekkür unsurları: 1 Kendi Gök Kubbemiz'de duygu

    Başlık çevirisi yok

    MUSTAFA ÖZBALCI

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Gazi Üniversitesi

    Türk Dili ve Edebiyatı Ana Bilim Dalı

    Yükleniyor...

  5. Sivas yöresinde os trigonum oranının radyolojik olarak araştırılması

    An Investigation about the incidence of os trigonumin Sivas

    MEHMET ÇİMEN

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    Cumhuriyet Üniversitesi

    Morfoloji Ana Bilim Dalı

    Yükleniyor...