Geri Dön

Ağızda kuvvet yüklemesi yapılarak kullanılmış olan ve yepyeni ortodontik mini implantlarda farklı pH değerlerinde meydana gelen iyon salımlarının in vitro olarak karşılaştırılması

In vitro comparison of ion releases at different pH values in mini implants used with force application in mouth and in as recieved mini implants

  1. Tez No: 776982
  2. Yazar: MEHMET BARAN AYDUK
  3. Danışmanlar: PROF. DR. TEVFİK HAKAN BULUT
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Ankrajlar, Dental implantasyon, Dental implantlar, Hidrojen iyon konsantrasyonu, Kütle spektrometri, Mikroskopi-elektron taramalı, Ortodonti, Tükürük, İyon, Anchorages, Dental implantation, Dental implants, Hydrogen-ion concentration, Mass spectrometry, Microscopy-electron scanning, Orthodontics, Saliva, Ion
  7. Yıl: 2022
  8. Dil: Türkçe
  9. Üniversite: Ege Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Ortodonti Ana Bilim Dalı
  12. Bilim Dalı: Ortodonti Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Amaç: Bu çalışmanın amacı kullanılmış ve kullanılmamış ortodontik mini implantların farklı asitlik derecesine sahip ortamlardaki uzun dönemli iyon salım miktarlarının ve yüzey topografisinin karşılaştırılması ve mini implantların yeniden kullanılabilme olasılığının değerlendirilmesidir. Yöntem: Çalışmada 30 adet ağızda ortodontik kuvvet yüklemesi yapılarak kullanılmış ve 30 adet yeni mini implant kullanılmıştır. Modifiye Fusayama solüsyonu rehber alınarak pH değeri 2 ve pH değeri 7 olan yapay tükürük solüsyonları hazırlanmıştır. Mini implantlar bu solüsyonlara ayrı cam tüpler içerisinde yerleştirilmiştir. Cam tüpler araştırma periyotları boyunca sıcaklığı 37 °C'de sabit tutulan etüv içerisinde saklanmıştır. Örnekler; 30. gün, 60. gün ve 180. günün sonunda solüsyonlardan alınmış ve bir ICP-MS cihazı yardımıyla çözünmüş haldeki titanyum, alüminyum ve vanadyum iyonlarının miktarı kantitatif olarak tespit edilmiştir. Solüsyonların analizini takiben deneye tabi tutulmuş mini implantların yüzey topografileri SEM ve SPM cihazları ile değerlendirilmiştir. Bulgular: Analizlerde etkileşim ve önem seviyesi (p) 0.05 olarak kabul edilmiştir. Araştırmaya dahil edilen mini implantlar arasından sadece pH 2 V, (p<0.001) pH 2 Ti (p<0.001) ve pH 7 V (p=0.01) gruplarında kullanılmamış mini implantlarda kullanılmışlara göre daha fazla iyon salımı meydana gelmiştir. Diğer gruplarda mini implantların kullanımı ile meydana gelen iyon salımı arasında bir ilişki tespit edilememiştir. Araştıma sonucuna göre kullanılmış mini implantlarda meydana gelen korozyon miktarının kullanılmamışlardan daha yüksek olmadığı tespit edilmiştir. pH değeri 2 olan solüsyonda tespit edilen iyon miktarı, pH değeri 7 olan solüsyonda tespit edilene göre anlamlı şekilde yüksektir. (p<0.05) İyon salım miktarı ile geçen süre arasında bütün gruplar için geçerli bir ilişki tespit edilememiştir. SEM görüntüleri değerlendirildiğinde kullanılmış mini implantların yüzeyinde farklı şekil ve büyüklükte eklentiler bulunduğu ve bazı aşınmaların oluştuğu gözlenmektedir. SPM görüntüleri değerlendirildiğinde artan asitlik derecesine paralel olarak incelenen mini implant yüzeylerinin daha girintili çıkıntılı bir hal aldığı gözlenmektedir. Kullanılmamış mini implantların yüzeyleri kullanılmış olanlara göre daha düzdür ve yüzeylerinin üzerinde daha küçük ve az sayıda eklenti bulunmaktadır. Sonuç: Araştırmada, kullanılmış mini implantlarda meydana gelen iyon salımı miktarlarının yeni olanlardan daha yüksek olmadığı tespit edilmiştir. Laboratuvar koşullarında yapılan bu çalışmanın sonuçlarına göre, kullanılmış mini implantların tekrar kullanılmasının, iyon salım miktarı ve bunun lokal ve sistemik etkileri göz önünde bulundurulduğunda, ek bir problem teşkil etmeyeceği değerlendirilmiştir. Öte yandan kullanılmış mini implantların yüzeyinde meydana gelen mikro ve makro değişikliklerin mini implantların uygulama ve fonksiyonunu olumsuz etkileyebileceği mutlaka göz önünde bulundurulmalıdır. Düşük pH değerine sahip ortamda meydana gelen iyon salım miktarı, daha yüksek pH değerine sahip ortamdakine göre belirgin biçimde daha yüksektir. Bu sebeple ağız içi pH düzeyleri farklı sebeplerle düşük olan hastalarda mini implantlar dikkatli şekilde kullanılmalı, intoleransı olan hastalarda bu araçların sebep olabileceği alerjik reaksiyonlar, lokal ve sistemik toksisite gibi yan etkilerin şiddetlenebileceği unutulmamalıdır.

Özet (Çeviri)

Aim: The aim of this study was to compare the long-term ion release amounts and surface topography of retrieved and as received orthodontic mini-implants in different acidity environments and to evaluate the reusability of mini-implants. Method: In the study, 30 mini-implants pre-used with orthodontic force loading in human mouth and 30 as received (new) mini-implants were used. Artificial saliva solutions with a pH of 2 and pH of 7 were prepared by taking the modified Fusayama solution as guide. Mini-implants were placed in these solutions in separate glass tubes. The tubes were then kept in an incubator at a constant temperature of 37 °C. At the end of 30th, 60th and 180th days, samples were taken from the solutions and the amount of dissolved titanium, aluminum and vanadium ions were determined by an ICP-MS device. After the analyses of the solutions, the surface topographies of the tested mini-implants were evaluated with SEM and SPM devices. Results: Interaction and significance level (p) was accepted as 0.05 in the analyses. Only in the groups; pH of 2 V, (p<0.001) pH of 2 Ti (p<0.001) and pH of 7 V (p=0.01) as received mini-implants released more ions than retrieved mini-implants. No relationship was found between the use of mini-implants and the resulting ion release in other groups. In this study it was revealed that the amount of corrosion occurring in the retrieved mini-implants was not higher than the as received ones. The amount of ions detected in the solutions with a pH of 2 was higher than in the solutions with a pH of 7 (p<0.05). For all groups a valid relationship between the amount of ion release and time could not be established. When SEM images were evaluated, it was observed that there are abrasions and integuments of different shapes and sizes on the surface of the retrieved mini-implants. When the SPM images are evaluated, it is observed that the examined mini implant surfaces become more indented as the acidity level increased. The surfaces of as received mini-implants were relatively flat and had smaller and fewer attachments on their surfaces. Conclusion: It was determined that the amount of dissolution occurred in retrieved mini-implants was not higher than occurred in as received ones. According to the results of the study carried out under laboratory conditions, the reuse of retrieved mini- implants does not pose an additional problem when only the amount of ion release and its local and systemic effects are considered. On the other hand, it should be taken into consideration that micro and macro changes on the surface of retrieved mini-implants may adversely affect the application and function of mini-implants. The amount of ion release occurring in the medium with low pH values was found significantly higher than in the medium with relatively higher pH value. For this reason, dental miniimplants should be used carefully in patients with low intraoral pH levels and it should be bared in mind that side effects such as allergic reaction, local and systemic toxicity that these appliances cause may intensify.

Benzer Tezler

  1. Bruksizm vakalarında implant destekli 3 üyeli solid zirkonyum seramik ve metal-seramik restorasyonların kullanım süreleri ve kırılma dirençlerinin bruksizmi yansıtan çiğneme simülatöründe değerlendirilmesi

    3 members of implant supported solid zirconia ceramic and metal-ceramic restoration that bruxism case simulation by the chewing simulator for measuring restoration useful and fracture resistance with bruxism

    ALİ CAN BULUT

    Doktora

    Türkçe

    Türkçe

    2015

    Diş HekimliğiKırıkkale Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. SAADET ATSÜ

    PROF. DR. SEMİH BERKSUN

  2. Yaşlı bireylerde protetik sağaltımın başarısını arttırıcı tasarımlar

    Different design options to increase the success of prosthodontic treatment in elderly

    MEHMET ALİ HACIOĞLU

    Doktora

    Türkçe

    Türkçe

    2012

    Diş HekimliğiEge Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. MUSTAFA GÖKHAN AKSOY

  3. Laminate veneerlerde termal ve yükleme kuvvetlerinin oluşturduğu stres dağılımının üç boyutlu sonlu elemanlar metodu ile incelenmesi

    The investigation of stress patterns in porcelain laminate veneers induced by thermal and functional loads: A 3D finite element analysis study.

    ÖZLEM ÜSTÜN

    Doktora

    Türkçe

    Türkçe

    2008

    Diş HekimliğiSelçuk Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. NİLGÜN ÖZTÜRK

  4. Farklı kalınlıktaki okluzal splintlerin temporomandibular eklem üzerine oluşturduğu stres dağılımının araştırılması

    The investigation of the stress distribution of the occlusal splints of different thickness on the temporomandibular joint

    AHMET ERDEM

    Doktora

    Türkçe

    Türkçe

    2019

    Diş HekimliğiBezm-İ Alem Vakıf Üniversitesi

    Ağız, Diş ve Çene Cerrahisi Ana Bilim Dalı

    DOÇ. DR. NÜKHET KÜTÜK

  5. Titanyum abutment ve metal destekli restorasyonlara alternatif peek materyallerinin kullanımı sonrası peri-implant kemikte, implantta, kronda, abutmentta ve vidada oluşan streslerin sonlu elemanlar stres analizi ile karşılaştırması

    Comparison the stresses occurring in the peri-implant bone, implant, superstructure, abutment and screw after using peek materials, which are alternative to titanium abutments and metal-supported restorations, by finite element stress analysis

    SAMET TEKİN

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2017

    Diş HekimliğiDicle Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    YRD. DOÇ. DR. YALÇIN DEĞER