Parabolik oluklu güneş kolektörü içeren doğal dolaşımlı güneş enerji sisteminin deneysel ve sayısal incelemesi

Experimental and numerical investigation of natural circulating solar energy system including a parabolic trough solar collector

  1. Tez No: 780212
  2. Yazar: BURHAN BAYHAN
  3. Danışmanlar: DOÇ. DR. GÖKHAN ARSLAN
  4. Tez Türü: Doktora
  5. Konular: Enerji, Makine Mühendisliği, Energy, Mechanical Engineering
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2022
  8. Dil: Türkçe
  9. Üniversite: Mersin Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Makine Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 98

Özet

Günümüzde tek uçlu eğimli borularda en yaygın doğal akış su ısıtma sistemleridir. Bu çalışmada, parabolik oluklu güneş kolektörü içeren doğal dolaşımlı güneş enerji sisteminin deneysel ve sayısal incelenmesi amaçlanmıştır. Bu amaçla başta dış ortamda K-G ekseninde bir boyutlu güneşi takip eden parabolik oluklu güneş kolektörü içeren doğal dolaşımlı güneş enerji sistemi kurulmuştur. Farklı tarihlerde deneyler yapılmıştır. Hareketli kolektörün açıklığına gelen ışınım değerleri hesaplanmıştır. SolTrace programı ile bu ışınımın % 56'lık kısmının kolektörün odağında bulunan vakum tüplü cam boruya ulaşabildiği bulunmuştur. Ayrıca vakum tüplü cam borunun tank girişine yakın kesiti için her deney için Rayleigh sayısı hesaplanarak deney boyunca doğal dolaşımın olup olmadığı izlenmiştir. Vakum tüplü cam borunun kapalı ucuna doğru boru uzunluğu boyunca doğal dolaşımın varlığının sorgulanması için bu kısımlarda ayrıca sıcaklık ölçümü gerekmiştir. Vakum tüplü cam boruya delik delme gibi işlemlerde zorluk ve dar açık ucundan termoeleman tellerinin akışa engel olma durumları göz önünde bulundurularak dış ortamda kurulan bu deney düzeneğine benzer deney düzeneği laboratuvar ortamında kurulmuştur. Bu deney düzeneğinin farkı, eğimli borunun galvanizli sacdan oluşması ve borunun çubuk rezistanslar ile ısıtılmasıdır. Bu deney düzeneği ile tek uçlu eğimli bir boruda, tank içi enerji dengesi ile akışkanın boru çıkış sıcaklığının tahmini, doğal dolaşımın debi hesabı ve diğer ısıl hesaplamalar için bir model oluşturulmuştur. Ayrıca bu model literatürdeki Li modeli ile kıyaslanmış olup, daha kolay ve daha başarılıdır. Toplam 6 saat süren deneylerde tek uçlu eğimli bir boruya 100, 200, 400, 600 ve 800 W ısıl güç uygulanmış ve sıcaklık değerleri 5 dakikalık periyotlarla kaydedilmiştir. Deneylerin ortalaması olarak, mevcut model ve Li modeli için tahmin sonuçları aşağıdaki gibidir: Ortalama yüzde bağıl hata oranları sırasıyla 6,02 ve 15,1 ve belirleme katsayısı (R2) sırasıyla 0,9865 ve 0,9683'tür. Ayrıca laboratuvar ortamında kurulan deney düzeneğinde yapılan deneylerde, sadece borunun tank girişine yakın ve boruya olan iç akışın başlangıç noktasındaki sıcaklığın ölçülmesiyle diğer nokralardaki sıcaklıkların tahmin edilmesi amaçlanmıştır. Bu amaçla, sıcaklık verileri ve mesafe arasında ilişki kurulup denklemler elde edilmiştir. Bu denklemler ile eğimli borunun yedi noktasındaki sıcaklıklar tahmin edilmiş olup en yüksek ortalama yüzde bağıl hata oranı 18,5 ile bir noktada elde edilmiştir. Diğer altı noktada ise ortalama yüzde bağıl hata oranı 3,5 olarak oldukça başarılı sonuç vermiştir. Son olarak, Ansys (Fluent) ile laboratuvarda yapılan deneylerin sayısal analizi yapılmıştır. Sayısal analiz sonucunda hız vektörleri ve sıcaklık konturları elde edilmiştir.

Özet (Çeviri)

The most common natural flow water heating systems in one-ended inclined pipes today. In this study, it is aimed to investigate the natural circulation solar energy system experimentally and numerically with parabolic trough solar collector. For this purpose, a natural circulation solar energy system including a parabolic trough solar collector that follows the sun in one dimension on the N-S axis in the outdoor environment has been established. Experiments were carried out on different dates. The radiation values coming into the opening of the moving collector were calculated. With the SolTrace program, it has been found that 56% of this radiation can reach the vacuum tube glass pipe in the focus of the collector. In addition, the Rayleigh number was calculated for each experiment for the section of the glass tube close to the tank inlet, and it was monitored whether there was natural circulation throughout the experiment. In order to question the existence of natural circulation along the length of the tube towards the closed end of the evacuated glass tube, additional temperature measurement was required in these parts. Considering the difficulty in drilling holes into the evacuated glass tube and the obstruction of the flow of the thermocouple wires from the narrow open end, the experimental setup similar to this experimental setup was set up in the laboratory environment. The difference of this experimental setup is that the inclined pipe is made of galvanized sheet and the pipe is heated with rod resistances. With this experimental setup, a model was created for estimating the energy balance in the tank and the pipe outlet temperature of the fluid, the flow rate calculation of the natural circulation and other thermal calculations in a single-ended inclined pipe. In addition, this model has been compared with the Li model in the literature, and it is easier and more successful. In the experiments lasting 6 hours in total, 100, 200, 400, 600 and 800 W thermal power was applied to a one-ended inclined pipe and the temperature values were recorded in 5-minute periods. As the average of the experiments, the estimation results for the present model and the Li model are as follows: The average percent relative error rates are 6.02 and 15.1 and the coefficient of determination (R2) is 0.9865 and 0.9683, respectively. In addition, in the experiments carried out in the experimental setup set up in the laboratory, it is aimed to estimate the temperatures at other points by measuring the temperature only at the starting point of the internal flow to the pipe, close to the tank entrance. For this purpose, equations were obtained by establishing a relationship between temperature data and distance in excel. With these equations, the temperatures at seven points of the inclined pipe were estimated, and the highest average percent relative error rate was obtained at one point with 18.5. In the other six points, the average percent relative error rate was 3.5, giving a remarkably successful result. Finally, numerical analysis of the experiments performed in the laboratory with Ansys (Fluent) was performed. As a result of numerical analysis, velocity vectors and temperature contours were obtained.

Benzer Tezler

  1. Nanoakışkan kolektörlü ve faz değişim malzemesinin kullanıldığı bir güneş enerjili damıtma sisteminin deneysel ve teorik analizi

    Experimental and theoretical analysis of a solar distillation system with nanofluid collector and phase change material

    VOLKAN TUĞAN

    Doktora

    Türkçe

    Türkçe

    2024

    EnerjiFırat Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    PROF. DR. MUSTAFA İNALLI

  2. Isı depolu parabolik oluklu güneş kolektörünün performans analizi

    Performance analysis of parabolic through solar collector with heat storage

    BURAK AKINCI

    Yüksek Lisans

    Türkçe

    Türkçe

    2023

    EnerjiKarabük Üniversitesi

    Enerji Sistemleri Mühendisliği Ana Bilim Dalı

    DOÇ. DR. ALPER ERGÜN

  3. Modelling, transient simulations and parametric studies of parabolic trough collectors with thermal energy storage

    Isıl enerji depolamalı parabolik oluklu kolektörlerin modellenmesi, zamana bağlı benzetimi ve parametrik çalışması

    TUFAN AKBA

    Yüksek Lisans

    İngilizce

    İngilizce

    2014

    EnerjiOrta Doğu Teknik Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    DOÇ. DR. ALMILA GÜVENÇ YAZICIOĞLU

    DOÇ. DR. DEREK KEITH BAKER

  4. Techno-economic analysis of middle-size PTC power plant for a university campus

    Bir üniversite kampüsü için orta ölçekli PTC enerji santralinin tekno-ekonomik analizi

    GÖZDE TAYLAN

    Yüksek Lisans

    İngilizce

    İngilizce

    2019

    EnerjiOrta Doğu Teknik Üniversitesi

    Sürdürülebilir Çevre ve Enerji Sistemleri Ana Bilim Dalı

    DOÇ. DR. MURAT FAHRİOĞLU

  5. Energy management and 4E analysis of a solar hybrid gas turbine power plant in Iraq

    Irak'ta bir güneş hibrit gaz türbini enerji santrali için enerji yönetimi ve 4E analizi

    WADAH TALAL TAHA AL-TEKREETY

    Doktora

    İngilizce

    İngilizce

    2024

    Makine MühendisliğiKarabük Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ ABDULRAZZAK AHMED SALEH AKROOT