Düz panel dedektör tabanlı dijital floroskopi sistemi kullanılarak gerçekleştirilen nörogirişimsel radyoloji incelemelerinde hasta ve personelin aldığı radyasyon dozunun ölçülmesi

Measuring of the radiation dose received by patients and staff in neurointerventional radiology examinations using a flat panel detector based on a digital fluoroscopy system

  1. Tez No: 807669
  2. Yazar: SİNEM ARIMAN
  3. Danışmanlar: PROF. DR. TURAN OLĞAR
  4. Tez Türü: Yüksek Lisans
  5. Konular: Radyoloji ve Nükleer Tıp, Radiology and Nuclear Medicine
  6. Anahtar Kelimeler: Nörogirişimsel radyoloji, hasta/personel dozu, DAP, hava kerma, FPD, OSL, Doz-cevap ilişkisi-radyasyon, Radyasyon, Radyasyon dozajı, Radyasyon ölçüm tekniği, Radyografi, Radyoloji, Radyoloji-girişimsel, Neurointerventional radiology, patient/personnel dose, DAP, air kerma, FPD, OSL, Dose-response relationship-radiation, Radiation, Radiation dosage, Radiation measurement technique, Radiography, Radiology, Radiology-interventional
  7. Yıl: 2023
  8. Dil: Türkçe
  9. Üniversite: Ankara Üniversitesi
  10. Enstitü: Nükleer Bilimler Enstitüsü
  11. Ana Bilim Dalı: Medikal Fizik Ana Bilim Dalı
  12. Bilim Dalı: Sağlık Fiziği Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Girişimsel nöroradyoloji incelemeleri, hasta ve çalışanların en yüksek radyasyon dozuna maruz kaldıkları incelemeler arasında yer almaktadır. Bu tezin amacı, dijital anjiyografi sisteminde nörogirişimsel radyoloji incelemeler için hasta dozlarının Doz-Alan Çarpımı (Dose-Area Product, DAP) ve Kümülatif Hava Kerma (Cumulative Air Kerma, CAK) cinsinden ölçülmesidir. Ayrıca hasta dozu ile eş zamanlı olarak personel dozu da ölçülerek inceleme ve hasta birim DAP değeri başına lens, parmak ve tüm vücut etkin dozları belirlenmiştir. Çalışmada bir C-kollu floroskopi sistemi kullanılmıştır. Çalışmanın başlangıcında sistemin kalite kontrol ve performans ölçümleri gerçekleştirilmiştir. Hasta doz ölçümünde Doz-Alan Çarpımı (Dose-Area Product, DAP) ve kümülatif hava kerma (Cumulative Air Kerma, CAK) ölçüm metotları kullanılmıştır. Çalışan dozlarının hesaplanmasında Niklason vd. 1994 ve Borrego vd. 2020 matematiksel denklemleri kullanılmıştır. Bunun için bel hizasında kurşun önlük altında ve tiroit koruyucu üstünde olmak üzere iki ayrı noktada, Berilyum Oksit (BeO) kristal içeren Optik Uyarmalı Lüminesans (OSL) dozimetre içeren kartlar taşınarak doz ölçümü yapılmıştır. Bu OSL dozimetreler ile tüm vücut için personel doz eşdeğeri Hp(10), göz lensi için doz eşdeğeri Hp(3) ve cilt için kişisel doz eşdeğeri Hp(0.07) ölçülmüştür. Hasta doz ölçümleri toplam 86 hasta (65 serebral ve 21 karotis) için gerçekleştirilmiştir. Serebral tanı/tedavi incelemeleri için hasta DAP ve CAK değerleri sırasıyla 73;143 Gy·cm2 ve 657;1888 mGy olarak ölçülmüştür. Benzer şekilde, karotis tanı/tedavi incelemeleri için hasta DAP ve CAK değerleri sırasıyla 40;79 Gy·cm2 ve 487;679 mGy olarak ölçülmüştür. DAP değerlerinden hesaplanan hasta etkin dozları serebral tanı/tedavi ve karotis tanı/tedavi incelemeleri için sırasıyla 4,04;8,16 mSv ve 2,11;3,93 mSv'tir. Personel dozları, hasta dozları ile eşzamanlı olarak toplam 30 serebral ve 8 karotis incelemesi için ölçülmüştür. Niklason vd. 1994 ve Borrego vd. 2020 matematiksel denklemlerine göre hekim, hemşire ve teknisyen için inceleme başına ölçülen tüm vücut etkin dozları sırasıyla 12,63;19,74 µSv, 7,11;11,05 µSv ve 10,00;15,26 µSv'tir. Hekim, hemşire ve teknisyen için inceleme başına ölçülen lens dozları sırasıyla 18,68, 19,74 ve 13,42 µSv'tir. İnceleme başına ekstremite dozları ise hekim için 54,74, hemşire için 15,26 ve teknisyen için 14,21 µSv olarak ölçülmüştür. 2023, 65 sayfa

Özet (Çeviri)

Interventional neuroradiology examinations are among the examinations in which patients and personnel are exposed to the highest radiation dose. The aim of this thesis is to measure patient doses in terms of Dose-Area Product (DAP) and Cumulative Air Kerma (Cumulative Air Kerma, CAK) for neurointerventional radiology studies in digital angiography system. In addition, the personnel dose was measured simultaneously with the patient dose, and lens, finger and whole-body effective dose determined per examination and patient unit DAP value. In the study, an C-arm fluoroscopy system was used. At the beginning of the study, the quality control and performance measurements of the system were carried out. Dose-Area Product (DAP) and cumulative air kerma (CAK) measurement methods were used for patient dose measurement. Niklason et al. 1994 and Borrego et al. 2020 algorithms were used to calculate personnel doses. For this purpose, dose measurement was made by carrying cards containing Optically Stimulated Luminescence (OSL) dosimeter consisting of BeO crystal at two different points, one dosimeter under the lead apron at waist level and the other at the neck outside the apron. With these OSL dosimeters, the personnel dose equivalent Hp(10) for the whole body, the dose equivalent Hp(3) for eye lens and the personal dose equivalent Hp(0.07) for the skin were measured. Patient dose measurements were performed for a total of 86 patients (65 cerebral and 21 carotid). For cerebral diagnostic/therapeutic investigations, patient DAP and CAK values were measured as 73;143 Gy·cm2 and 657;1888 mGy, respectively. Similarly, patient DAP and CAK values for carotid diagnostic/therapeutic investigations were measured as 40;79 Gy·cm2 and 487;679 mGy, respectively. Patient effective doses calculated from DAP values are 4.04;8.16 mSv and 2.11;3.93 mSv for cerebral diagnostic/therapeutic and carotid diagnostic/therapeutic investigations, respectively. Staff doses were measured for a total of 30 cerebral and 8 carotid examinations simultaneously with patient doses. According to the Niklason/Borrego algorithms, the measured whole body effective doses per examination for the physician, nurse, and technician are 12.63;19.74 µSv, 7.11;11.05 µSv, and 10.00;15.26 µSv, respectively. The measured lens doses per examination for the physician, nurse, and technician were 18.68, 19.74, and 13.42 µSv, respectively. The extremity doses per examination were measured as 54.74 µSv for the physician, 15.26 µSv for the nurse and 14.21 µSv for the technician. 2023, 65 pages

Benzer Tezler

  1. Dokuma kumaşlarda örgü tipinin ham kumaşın boyutları ve geometrik özellikleri üzerindeki etkilerinin araştırılması

    Başlık çevirisi yok

    EMEL ÖNDER

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Tekstil Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  2. Düz atkı örme kumaşlarda ilmek eğikliğinin iplik özellikleri ile ilişkisi üzerine bir araştırma

    Başlık çevirisi yok

    FATMA ÇEKEN

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Tekstil Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  3. Integrable {e}-structures and integrable G-structures for a finite group G

    İntegrallenebilir {e}- yapıları ve sonlu bir grup için integrallenebilir G-yapıları

    BELGİN KARAMAN

    Yüksek Lisans

    İngilizce

    İngilizce

    1987

    Orta Doğu Teknik Üniversitesi

    Matematik Ana Bilim Dalı

    Yükleniyor...

  4. Çeşitli rib örgülerin boyutsal özellikleri üzerine bazı araştırmalar

    Başlık çevirisi yok

    ARZU YAĞCI

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Ege Üniversitesi

    Tekstil Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  5. Melanogryllus desertus (pall.) (orthoptera)'da ışığın etkisi ve ışığa duyarlı baş bölgelerinin belirlenmesi

    Başlık çevirisi yok

    ERTAN TAŞKAVAK

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Ege Üniversitesi

    Zooloji Ana Bilim Dalı

    Yükleniyor...