Geri Dön

Ranque-hılsch vorteks tüp soğutmalı üç fazlı asenkron makinenin elektriksel parametrelerinin deneysel olarak incelenmesi

Experimental investigation of the electrical parameters of ranque-hilsch vortex tube-cooled three phase asynchronous machine

  1. Tez No: 808879
  2. Yazar: İSMAİL CEBECİ
  3. Danışmanlar: DOÇ. DR. VOLKAN KIRMACI, DR. ÖĞR. ÜYESİ SERKAN GÜRKAN
  4. Tez Türü: Doktora
  5. Konular: Makine Mühendisliği, Mechanical Engineering
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2023
  8. Dil: Türkçe
  9. Üniversite: Bartın Üniversitesi
  10. Enstitü: Lisansüstü Eğitim Enstitüsü
  11. Ana Bilim Dalı: Makine Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Makine Mühendisliği Bilim Dalı
  13. Sayfa Sayısı: 97

Özet

Enerjinin etkin, verimli ve en az kayıpla kullanımı, dünya üzerinde yoğunlaşılan önemli problem sahalarından biri haline gelmiştir. Üretilen enerjinin kullanım oranları incelendiğinde; büyük bir bölümünün sanayi sektöründe, sanayi sektöründeki kullanım oranları incelendiğinde ise enerjinin neredeyse yarıya yakınının elektrik motorları tarafından tüketildiği görülmektedir. Bu bilgilerden hareketle enerji verimliliğinde odak noktalarının başında sanayi sektörünün geldiğini, sanayi sektöründe ise elektrik motorlarının verimliliklerinin ön planda tutulması gerektiği açık bir şekilde görülmektedir. Elektrik motorlarında; çalışma anında enerji dönüşümü ile sürtünme vb. nedenlerle meydana gelen yüksek sıcaklık, motorun ekonomik ömründe, etkinliğinde ve verimliliğinde azalmalara neden olmaktadır. Bu nedenlerden ötürü elektrik motorlarında çalışma anında meydana gelen ısının uzaklaştırılması önemli bir meseledir. Bu çalışmada, elektrik motorundaki çalışma anında meydana gelen ısının azaltılarak, verimliliğinin arttırılması hedeflenmiştir. Çalışmada; 1,1 kW gücünde, elektriksel ve fiziksel parametreleri bilinen, IE3 verimlilik sınıfında rotoru sincap kafesli bir asenkron motorun soğutulması için, karşıt akışlı Ranque-Hilsch Vorteks Tüpü ilk defa kullanılmıştır. Çalışmalar, deneysel ve benzetim olmak üzere iki aşamada gerçekleştirilmiştir. Benzetim çalışmasında, ANSYS Motor-CAD yazılımından yararlanılarak, öncelikle boşta çalışma sonuçları ve ardından elektrik motorunun kapalı bir kabin içerisinde çalıştırıldığı ve kabin içi sıcaklığın vorteks tüpü vasıtasıyla soğutulduğu varsayılarak güç ve verim analizleri gerçekleştirilmiştir. Deneysel çalışmalarda; elektrik motoru alternatör ile akuple edilmiş, ortam sıcaklığı sırasıyla 25 ℃, 20 ℃, 15 ℃, 10 ℃, 5 ℃ ve 0 ℃ sıcaklıklara ayarlanmış, devir sayısı 95 rpm'den 950 rpm'e kadar 95'er rpm arttırılmış, yükleme %100, %75, %50 olacak şekilde çalıştırılmış ve 3 kez tekrarlanan deney sonuçları kaydedilmiştir. Gerçekleştirilen çalışmalar kapsamında; benzetim çalışmaları neticesinde, geleneksel fanlı soğutma ile önerilen soğutma sistemi karşılaştırıldığında, verimlilikte %1,22'lik artış elde edilirken, deneysel çalışmalar neticesinde %1,79'luk verimlilik artışı olmuştur.

Özet (Çeviri)

The effective, efficient, and loss-free use of energy has emerged as one of the world's most pressing issues. When the usage rates of the produced energy are examined, it is discovered that the majority of the energy is consumed in the industrial sector, and when the usage rates in the industrial sector are examined, it is discovered that electric motors consume nearly half of the energy. According to this information, it is clear that the industrial sector is the primary focus in terms of energy efficiency and that electric motor efficiency should be prioritized in the industrial sector. High temperatures in electric motors caused by energy conversion, friction, and other factors during operation reduce the motor's economic life, efficiency, and reliability. As a result, it is critical to remove the heat generated during the operation of electric motors. The goal of this research is to improve the efficiency of the electric motor by reducing the heating that occurs during operation. In the study, a counter-flow Ranque-Hilsch Vortex Tube was used for the first time to cool a 1,1 kW asynchronous motor with known electrical and physical parameters and in the IE3 efficiency class. The study was divided into two stages: experimental and simulation. In the simulation study, using ANSYS Motor-CAD software, the results of the idling operation were first analyzed, followed by power and efficiency analyses, assuming that the electric motor is operated in a closed cabinet and the temperature inside the cabinet is cooled by a vortex tube. In the experimental studies, the electric motor was coupled with the alternator, the ambient temperature was adjusted to 25 °C, 20 °C, 15 °C, 10 °C, 5 °C, and 0 °C, respectively, the speed was increased by 95 rpm from 95 rpm to 950 rpm, the loading was run at 100%, 75%, and 50%, and the results of the experiment were recorded three times. Within the scope of the studies, when the conventional fan cooling and the proposed cooling system were compared, the simulation studies resulted in an increase in efficiency of 1,22%, while the experimental studies resulted in an increase in efficiency of 1,79%.

Benzer Tezler

  1. Basınçlı doğalgaz hatlarında vorteks tüpünün ısıtma amaçlı olarak kullanılabilirliğinin deneysel olarak araştırılması

    Experi̇mental investigation of the usability of vortex tube for heating in pressurized natural gas lines

    SERDAR ÇULUN

    Yüksek Lisans

    Türkçe

    Türkçe

    2022

    Mühendislik BilimleriBingöl Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ ÜSAME DEMİR

  2. Farklı parametrelere sahip jeneratörler kullanılarak bir vorteks tüpünün COP ve CMF değerlerinin deneysel olarak incelenmesi

    Experimental investigation of COP and CMF values of a vortex tube using generators with different parameters

    GÖKÇE ULUŞAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2022

    Makine MühendisliğiSakarya Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    PROF. DR. HÜSEYİN PEHLİVAN

  3. Yüksek enerji ayrıştırma etkisine sahip karşıt akışlı ranque-hilsch vorteks tüpü tasarımı geliştirilmesi ve bilgisayar destekli optimizasyonu

    Improving counter – flow ranque – hilsch vortex tube design with high energy separation effect and its computer aided optimization

    HASAN MELİH KINAGU

    Yüksek Lisans

    Türkçe

    Türkçe

    2017

    EnerjiUludağ Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    YRD. DOÇ. DR. MEHMET ÖZGÜN KORUKÇU

  4. Ranque-Hilsch vorteks tüpünde enerji ayrışmasının deneysel ve termodinamik incelenmesi

    Experimental and theoretical investigation of energy separation in Ranque-Hilsch vortex tube

    BURAK MARKAL

    Yüksek Lisans

    Türkçe

    Türkçe

    2010

    Makine MühendisliğiKaradeniz Teknik Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    PROF. DR. ORHAN AYDIN

  5. An experimental investigation of vortex tube performance characteristics

    Vorteks tüpünün performans özelliklerine deneysel bir inceleme

    YAKUB TÜFEKCİ

    Yüksek Lisans

    İngilizce

    İngilizce

    2009

    Makine MühendisliğiYeditepe Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    YRD. DOÇ. DR. NAMIK ÇIBLAK