Geri Dön

Ülkemizde geliştirilen modifiye anatomik plak ile proksimal femoral çivi, dinamik kalça vidası ve anatomik plak implantlarıın sonlu eleman analizi ve gerçek ortam testleri ile mukayese edilmesi

Comparison of modified anatomical plates, proximal femoral nails, dynamic hip screws, and anatomical plate implants developed in our country with finite element analysis and real-environment tests

  1. Tez No: 813870
  2. Yazar: ZAFER SOYDAN
  3. Danışmanlar: DR. FUAD ÖKEN
  4. Tez Türü: Tıpta Uzmanlık
  5. Konular: Ortopedi ve Travmatoloji, Orthopedics and Traumatology
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2007
  8. Dil: Türkçe
  9. Üniversite: Sağlık Bakanlığı
  10. Enstitü: Ankara Numune Eğitim ve Araştırma Hastanesi
  11. Ana Bilim Dalı: Ortopedi ve Travmatoloji Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 71

Özet

Femur üst uç kırıklarında internal tespit, özellikle yaşlı olmayan hasta grubunda temel cerrahi tedavidir. Çalışmamızın amacı bu bölgede internal tespit materyallerinin biomekanik değerlendirmesini yapmak ve modifiye ettiğimiz anatomik plağın sanal ortam ve gerçek ortam testleri ile analizini yapmaktır. Bu amaçla iki aşamalı yürüttüğümüz çalışmamızın birinci aşamasında sonlu eleman analizi yöntemiyle PFN, DHS, Anatomik Plak ve Modifiye Anatomik Plak üzerinde çalışıldı. Buradan elde edilen sonuçlar, ikinci aşamada gerçek ortam testinde elde edilen kırık hattı yüklenme analizi ile doğrulandı. Çalışmamızın sonucunda Modifiye Anatomik Plak , kırık hattındaki stres yönünden bir intramedüller implant olan PFN ile bir ekstramedüller implant olan DHS arasında sonuçlar vermiştir. Sanal ortam testi ile gerçek ortam testinin sonuçlarının kırık hattındaki stres yönünden tutarlılık gösterdiği görülmüştür. Femur üzerindeki streslerde ise sadece sonlu eleman analizinde elde edilen sonuçlarla çalışılmış ve modifiye anatomik plağın normal femur üzerindeki streslere çok yakın değerler verdiği görülmüştür. Plak femura uygulandıktan sonra, yüklenen kuvvetlerin oluşturduğu stresi üzerine başarıyla almakta ve“fizyolojik”yüklenme sağlamaktadır. Gerçek ortam testinin doğal olarak daha gerçekçi sonuçlar vereceği öngürülebilir. Çalışmamızda gerçek ortam testi ve sonlu eleman analizi birbiriyle tutarlı sonuçlar vermiştir. Her iki test sonucunda da en başarılı implantın PFN olduğu görülmektedir. Bunu PFN nin intramedüller bir implant olmasına bağlıyoruz. Sonuçlarımız PFN ile ilgili mekanik komplikasyonların literatürde neden düşük olduğunu da açıklar mahiyettedir. Sonuç olarak, modifiye ettiğimiz anatomik plağın biomekanik özellikleri diğer implantlardan daha fazla PFN ye yakın özelliktedir. Uygulanma kolaylığı ve düşük maliyetini de göz önüne alarak femur üst uç kırıklarında alternatif bir tedaviden çok standart bir tedavi olarak kullanılabilir düşüncesindeyiz.

Özet (Çeviri)

Internal fixation of proximal femoral fractures is the mainstay of internal fixation, especially in non-elderly patients. The aim of our study was to evaluate the biomechanical properties of internal fixation materials in this region and the modified anatomical plate in a virtual and real environment. For this purpose, in the first stage of our two-stage study, PFN, DHS, anatomic plate, and modified anatomic plate implants were studied with the finite element analysis method. The results obtained here were compared with the fracture line obtained in the real-environment test in the second phase. As a result of our study, the modified anatomical plate is effective in terms of stress on the fracture line. It is a result of the interaction between PFN, an intramedullary implant, and DHS, an extramedullary implant. It has been observed that the results of the virtual environment test and the real environment test are consistent in terms of stress at the fracture line. As a result of both tests, it is evident that the most successful implant is PFN. We attribute this to the fact that it is an intramedullary implant. Our results suggest mechanical effects regarding PFN. This also explains why complications are low in the literature. As a result, the biomechanical properties of the anatomical plate we modified are similar to others. It is closer to PFN than other implants. Considering the ease of application and low costs, we think it is a standard treatment rather than an alternative treatment for upper-end fractures of the femur.

Benzer Tezler

  1. Reaktif oksijen türleri süpürücü antioksidan aktivitenin ölçümünde modifiye CUPRAC yöntemlerinin geliştirilmesi

    Development of modified CUPRAC methods for reactive oxygen species scavenging antioxidant activity measurement

    MUSTAFA ÖZYÜREK

    Doktora

    Türkçe

    Türkçe

    2009

    Kimyaİstanbul Üniversitesi

    Kimya Ana Bilim Dalı

    PROF. DR. REŞAT APAK

  2. Biyolojik örneklerde reaktif oksijen türleri süpürme etkinliği ölçümü için spektrofotometrik yöntemler geliştirilmesi

    Development of spectrophotometric methods for measurement of reactive oxygen species scavenging activity in biological samples

    BURCU BEKDEŞER

    Doktora

    Türkçe

    Türkçe

    2012

    Kimyaİstanbul Üniversitesi

    Kimya Ana Bilim Dalı

    DOÇ. DR. MUSTAFA ÖZYÜREK

    PROF. DR. REŞAT APAK

  3. Süne zararının tespiti için florometrik yöntem geliştirilmesi

    Developing fluorometric method for detection of sunn pest damage

    BEGÜM ZEYNEP HANÇERLİOĞULLARI

    Yüksek Lisans

    Türkçe

    Türkçe

    2017

    BiyoteknolojiHacettepe Üniversitesi

    Gıda Mühendisliği Ana Bilim Dalı

    YRD. DOÇ. DR. FAHRİYE CEYDA DUDAK ŞEKER